Exide is a manufacturer recognized for producing high-performance industrial batteries tailored for demanding applications in sectors like telecommunications, renewable energy storage, and material handling equipment. Their products are revered for their durability, reliability, and cutting-edge technology, ensuring uninterrupted power supply in critical operations. [AI]
We repair a wide range of Exide Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Exide 118302384c is a battery charger commonly used in industrial applications. Its primary function is to restore the charge in lead-acid batteries through a controlled charging process. The device features multiple charging modes, including trickle charge, fast charge, and maintenance charge. Typical failures in the Exide 118302384c include fuse issues, faulty components in the charging circuitry, and overheating due to prolonged use. It is recommended to perform regular maintenance checks to ensure proper functionality and prevent potential breakdowns.
The EXIDE 101072372 B EXIDE DCV1 is a DC voltage regulator designed for industrial and automotive applications. It is equipped with features such as voltage regulation, surge protection, and overcurrent protection to ensure stable and reliable operation. Typical failures include blown fuses, damaged capacitors, and burnt-out components due to overloading or electrical surges. Regular maintenance and monitoring of voltage levels can help prevent these failures.
The Exide 101072371c is a battery charger commonly used in industrial applications. It is designed to charge lead-acid and gel cell batteries efficiently and safely. This model features a microprocessor-controlled charging algorithm to optimize the charging process and avoid overcharging. Typical failures can include blown fuses, faulty rectifier diodes, or malfunctioning control circuitry. Regular maintenance and periodic calibration are recommended to ensure optimal performance and prolong the device's lifespan.
The Exide 2000EX power inverter is designed to convert DC power from a battery or other power source into AC power for use in industrial settings. Its features include high efficiency, reliable performance, and various protective functions such as overload protection and overheat protection. Typical failures of this model include blown fuses, damaged MOSFETs, and capacitor issues. Regular maintenance and inspection are recommended to ensure optimal operation.
The Exide 2000EX is a Power Inverter & Charger unit designed for industrial applications. Its primary function is to convert DC power from batteries to AC power for various electrical devices, while also providing the capability to charge the batteries. This model typically features multiple input and output options, as well as surge protection and overload protection mechanisms. Common failures observed in the Exide 2000EX unit include burnt components, blown fuses, damaged capacitors, and failure in the charging circuit. These failures are often caused by overloading, excessive heat, or poor battery connections. Regular maintenance and monitoring of input/output voltages can help prevent these failures and ensure the unit's optimal performance.
The Exide 2000EX is a combination device that serves as both a battery charger and power inverter for industrial applications. It is designed to efficiently charge batteries and convert DC power to AC power. The device includes features such as multiple charging modes, voltage and current protection, and overload protection. Common failures of the Exide 2000EX may include output voltage fluctuations, overheating issues, or failure to switch between charging and inverting modes. These failures can be caused by component aging, poor connections, or internal circuitry faults. Regular maintenance and periodic inspections are recommended to ensure the device's optimal performance and reliability.
The EXIDE 101072370 D OMNICURE is a power inverter commonly used in industrial applications to convert DC power to AC power, allowing for the operation of various electronic devices. This model features a compact design, high efficiency, and reliable performance under heavy load conditions. Typical failures include blown fuses, faulty capacitors, and damaged semiconductors due to overloading or power surges. Regular maintenance and inspections can help prevent such issues and ensure the longevity of the device.
The Exide X1060-64-8 is a industrial battery charger commonly used for charging lead-acid batteries. It features a maximum output of 60 amps, 64 volts, and has 8 charging stages to ensure efficient and safe battery charging. Typical failures with the Exide X1060-64-8 include transformer faults, rectifier issues, control board malfunctions, and cooling fan failures. Regular maintenance and inspection of these components can help prevent unexpected downtime and ensure reliable performance of the battery charger.
The EXIDE UNKNOWN CHG & DIGITAL CONT BD is a battery charger and digital control board used in industrial applications. It is designed to regulate and maintain optimal charging conditions for batteries, ensuring they are charged efficiently and safely. Typical features include digital displays for monitoring charging status and adjustable settings for different battery types. Common failures in this model include malfunctioning digital displays, power supply issues, and component circuitry failures. Troubleshooting involves testing and replacing faulty components, recalibrating settings, and ensuring proper connection points.
The Exide 2000EX Power Inverter/Charger is designed to convert DC power from batteries into AC power for industrial equipment and charge the batteries simultaneously. This device features high efficiency, a wide input voltage range, and multiple protection functions like overload and short circuit protection. Typical failures in this model include blown fuses, damaged capacitors, or faulty power transistors due to overloading or poor ventilation. Regular maintenance and monitoring of input/output voltages and current levels are recommended to ensure proper functioning and prevent breakdowns.