The Parker Hannifin Twin 8 (TWIN8N) is a two‑axis brushless motor drive that accepts 3‑phase 380–480 VAC and outputs up to 2×8 A per axis (≈5.6 kVA). Common failure points in this class include input voltage dips or spikes, overcurrent protection tripping, overheating of the power stage (MOSFETs/IGBTs), and degradation of the DC‑link capacitors. First‑check diagnostics: verify that the 3‑phase supply is within spec and stable; inspect the main power board for burnt components, loose solder joints or damaged fuses; and review any fault codes or status LEDs on the drive’s front panel before proceeding to deeper inspection.[oss-gpt-20b] |