Beede 906898/1111 AC Kilovolts Meter is a high‑voltage panel meter used for measuring up to several kilovolts in industrial process control panels. Common failure points for units of this type include degraded input protection diodes, burnt or cracked PCB traces from voltage spikes, and aging display backlight or LCD driver ICs. Start diagnostics by verifying the 12 V/24 V supply rails with a multimeter, inspecting the board for burn marks or broken vias, and checking the meter’s displayed error codes (if any) against the service manual. If the display is blank, test the LCD power and signal lines; if the meter shows incorrect readings, examine input filtering capacitors and protection components for leakage or open circuits.[oss-gpt-20b] |