We repair a wide range of AC Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The AC Technology DL14250FA is an industrial variable frequency drive (VFD) commonly used for controlling the speed of induction motors in a wide range of applications. It features advanced control algorithms, a user-friendly interface, and a compact design. Typical failures of this model include capacitor failures, power module failures, and control board issues. Regular maintenance and periodic inspections are recommended to ensure optimal performance and longevity of the drive.
The Ac Technology sf210 is an industrial motor drive designed to control the speed and torque of AC motors. It features a compact design, high performance, and easy integration with various control systems. Common failures include overheating, power supply issues, and component failures due to electrical stress. Regular maintenance and monitoring can help prevent these failures and ensure optimal performance of the device.
The Ac Technology q24005c is a variable frequency drive (VFD) designed for controlling the speed of three-phase AC induction motors. It offers features such as adjustable frequency, torque control, and programmable digital inputs and outputs. Common failures in this device include overheating due to poor ventilation, capacitor failure, and power supply issues. Regular maintenance and monitoring of temperature and electrical connections can help prevent these failures.
The Ac Technology sf420 is a variable frequency drive used in industrial settings to control the speed of AC motors. It features an easy-to-use interface for programming and monitoring motor parameters such as speed, torque, and acceleration. Common failures include power module faults, capacitor issues, and problems with the control board. Proper maintenance and timely replacement of components can extend the lifespan of the device.
The AC Technology Q32030B is an industrial electronic drive used for controlling the speed and torque of three-phase AC induction motors. It features advanced motor control algorithms, digital signal processing, and a user-friendly interface for parameter adjustment and monitoring. Typical failures include power supply issues, component failures on the control board, and damage to the output stage due to overload or voltage spikes. Regular maintenance and proper cooling can help prolong the lifespan of the drive.
The AC Technology SBD2-10-2101 is a variable frequency drive (VFD) designed for controlling the speed of AC motors in industrial applications. It features a compact design, high efficiency, and advanced control capabilities. Common failures include overheating due to poor ventilation, power supply issues, and faults in the control circuitry. Regular maintenance and monitoring of operating conditions are essential to ensure optimal performance and longevity of the VFD.
The AC Technology M1420BH is a variable frequency drive (VFD) designed for controlling the speed of three-phase AC induction motors. It features high performance vector control, precise speed regulation, and a compact design. Typical failures in this model include power supply issues, blown fuses, overheating due to poor ventilation, and failure of internal control circuit components. Regular maintenance and timely repairs are essential to ensure optimal performance and longevity of the device.
The AC 25178756F is a printed circuit board commonly used in industrial equipment for various functions such as signal processing, control, and communication. It features a durable construction with high-quality components to ensure reliable operation in harsh industrial environments. Typical failures may include solder joint cracks, component failures, and damage from power surges or overheating. Proper maintenance and periodic inspections are recommended to ensure optimal performance and longevity of the AC 25178756F board.
The Ac Technology UNK model is a variable frequency drive used for controlling the speed of AC motors in industrial applications. It features a compact design, easy installation, and a user-friendly interface for programming various parameters such as speed control, acceleration, and deceleration. Typical failures of this model include power component failures such as blown fuses or damaged capacitors, overheating due to poor ventilation or overloading, and software malfunctions leading to erratic motor behavior. Regular maintenance and periodic checks are essential to ensure the smooth and reliable operation of the Ac Technology UNK drive.
The AC Technology M1410E is an industrial AC motor drive designed to control the speed and torque of AC motors. It features a compact design, dual microprocessor control, and a variety of input and output options for integration into industrial systems. Typical failures include power supply issues, overheating due to poor ventilation, and component failures in the control board. Maintenance should include regular cleaning, checking connections, and monitoring heat dissipation to ensure optimal performance.
I would like to know if you sell new or used accurite III dros?Mine is a lost cause. It was being used in the z axis and in congunction with Servo system 3 axis milling machine retro-fit, on a Lagun ftv-2 base machine. the 2 other axis dros are fine.. Bruceβ‘οΈ Reply Accu-Rite
where can i find a on line or other instruction manual for this Digital Read out?β‘οΈ Reply Accu-Rite
we wants setting least count 5 micron instead of 10 micron. please send me detailβ‘οΈ Reply Accu-Rite
I need to find or have ours repaired. It is a 10 scale for a hardinge lathe model 200T. The scale number is 550505-10β‘οΈ Reply Accu-Rite
My read out keeps giving me an e3 code . The readout starts reading out then goes to e3.The scale is clean also the readerhead had everything apart cleaned with alcohol . Can you help? The mode is a Millmate 2 axis it is on a Brigeport mill. Tomβ‘οΈ Reply Accu-Rite
Hello, I have a Accu-rite III dro, and just in stalled a new Y-axis scale.How do you change the resolution on the DRO?β‘οΈ Reply Accu-Rite
I have two Teledyne DRO Model 2000.Do you of anyone that can fix them? We can discuss the issue on the phone.β‘οΈ Reply Accu-Rite
To whom it may concern,I have an Accu Rite II Digital Readout System on my Bridgeport.The (X) axis reading head, is in need of a rebuild. Is this something your company does or can you refer me to someone?Any info. on this would be greatly appreciated. Thanks for your time,Craigβ‘οΈ Reply Accu-Rite
Subject Issue Report for ACRISON 060 PENDANTDear Repair Shop,This is to inform you that the ACRISON 060 PENDANT units have been frequently returned or reported for issues. As per the records, the problems remain unspecified. Technicians have indicated recurring unidentified faults. Your expertise is requested to diagnose and address these ongoing concernsβ‘οΈ Reply Acrison
Hello, We are in need of a replacement motor control board for an Accurpress MOT137. Could you provide us with repair info or assistance on how to resolve this issue quickly? Thank you!β‘οΈ Reply Accurpress
Have a mini X with poor read rates and would like to have it diagnosed and repaired. Do you expertise with this older type of scanner?β‘οΈ Reply Accu-Sort
Since your unit is reading poorly, it just needs adjustments to the return signal. I am a former Field Engineer from Accusort. Email if you have any questions.β‘οΈ Reply Accu-Sort
Hello, we need an offer for a second hand Mini-X scanner immediately and what is the approx. price of an new one.best regards,Mete AtayataBusiness DevelopmentAras Kargo PlazaKavacyk-Istanbulβ‘οΈ Reply Accu-Sort
Good Afternoon,My name is Christian Stasiak and I work for UPS as the IT End of Life Surplus Sale/E-recycling coordinator. I am contacting you this afternoon to see if you would be interested in bidding on a fairly large lot of used AccuSort DWS/Scanning equipment (models: AV3700, DM3000, APC-100 & AV4000). If you would be interested in participating, please let me know and I will send you a comprehensive equipment list with bidding instructions.Thanks!β‘οΈ Reply Accu-Sort
Can you repair these units? i have been given 2 by a customer.monitor. no video, possible bad power supply.β‘οΈ Reply Act-Kern
Subject Repeat Issue with Accuweb, Inc. 1.5x2u4042-01Dear Repair Shop,I am writing to report a recurring problem with the Accuweb, Inc. 1.5x2u4042-01 unit in our inventory. We have noticed that this specific unit keeps being returned or reported for unknown issues. According to our records, there seems to be a persistent issue with this particular model. Our technicians have indicated that customers are experiencing unidentified malfunctions with this unit. We would appreciate it if your team could provide further insight into this matter and recommend a course of action to address this issue efficiently.Thank you for your attention to this matter.Best regards,Inventory Managerβ‘οΈ Reply Accuweb, Inc
Subject Inquiry About Actechnology M341050c-474 Repair or Sale Hello,I hope this message finds you well. I am an office assistant tasked with seeking help regarding an Actechnology M341050c-474 device. Unfortunately, the description of the issue with the device is unknown.If you or your team have the expertise to repair or would be interested in purchasing this model, I would greatly appreciate any assistance or guidance you can provide.Thank you for your time and consideration.Warm regards,β‘οΈ Reply Actechnology
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.