Acu-Rite specializes in precision measurement and control equipment for industrial applications. They are known for their accurate and reliable digital readouts, linear encoders, and precision glass scales used in machinery and manufacturing processes. [AI]
We repair a wide range of Acu-Rite Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Acu-Rite SENC150 572282-25 is a scale unit commonly used in industrial applications for precise and accurate measurements of weight or force. It features a robust design with high resolution and accuracy, making it suitable for various industrial processes. Typical failures of the Acu-Rite SENC150 572282-25 can include issues with the load cell, such as signal drift or loss of sensitivity, as well as problems with the digital display or communication interface. Regular calibration and maintenance are essential to ensure optimal performance and prevent potential failures.
The Acu-Rite D200 Digital Readout is a crucial industrial electronic component used in machine tools for accurate position measurement and display. It features a high-resolution LCD screen for clear and precise numerical readouts, user-friendly interface for easy operation, and the capability to store presets for quick recall of frequently used settings. Typical failures in the Acu-Rite D200 Digital Readout include display malfunctions such as pixel fading or dead segments, keypad failures due to wear and tear, and power supply issues leading to erratic operation or complete failure. Regular maintenance and proper handling can extend the lifespan of this electronic component.
The Acu-Rite 2001004 is a digital readout (DRO) model designed for milling machines, lathes, and other metalworking machinery. It allows users to accurately measure and display the position of the machine's cutting tool or workpiece. Key features of the Acu-Rite 2001004 include a high-resolution LCD screen for clear readouts, programmable function keys for easy operation, and the ability to store reference points for quick setup. It also offers inch/metric conversion and error compensation functions to ensure precise measurements. Typical failures of the Acu-Rite 2001004 may include display malfunctions such as fading or flickering screens, keypad issues such as unresponsive or sticky buttons, or internal circuitry problems. Proper maintenance and periodic calibration can help prevent common failures in this type of industrial electronic device.
The ACU-RITE 387900251 is a digital readout (DRO) unit commonly used in industrial machines such as milling machines and lathes. It is designed to provide precise and accurate measurements of machine movements along the X, Y, and Z axes. This DRO unit features a bright LCD display, intuitive keypad interface, and various programmable functions for easy operation. Typical failures of the ACU-RITE 387900251 include display malfunctions such as flickering, fading, or completely blank screens. Keypad buttons may become unresponsive or register incorrect inputs. Internal electronic components such as resistors, capacitors, or integrated circuits may also fail, leading to overall system malfunction. Regular maintenance and periodic calibration can help prevent these issues.
The ACU-RITE 387575 200 is a digital readout display commonly used in industrial CNC machines to provide users with precise positioning and measurement information. It features a large illuminated LCD screen with easy-to-read numbers, function buttons for quick access to various settings, and a durable enclosure for protection in harsh industrial environments. Typical failures of the ACU-RITE 387575 200 may include display malfunctions such as flickering or dimming, unresponsive buttons, or inaccurate readings. These issues are often caused by damaged internal components, moisture ingress, or wear and tear from extended use. Repairing the display unit may involve component level troubleshooting, replacement of faulty parts, or calibration to restore accurate functionality.
The Acu-Rite 200S 2X M 535 882-12 is a Digital Readout (DRO) unit designed for use in industrial machines such as lathes and milling machines. It provides accurate and precise measurements of tool movement or position on the machine. The unit features a high-resolution display, easy-to-use interface, and various functions such as inch/metric conversion and calculation of absolute and incremental positions. Typical failures of this DRO unit may include display malfunctions, communication errors, power supply issues, or damage to the internal electronic components. These failures can often be diagnosed and repaired by troubleshooting the individual circuits and components within the unit.
The Acu-rite pulse scale digital readout is a precision measuring device used in industrial applications to provide accurate and reliable measurement readings. It typically features a high-resolution digital display, user-friendly interface, and advanced communication capabilities for data transfer. Common failures may include display malfunctions, communication errors, or sensor defects due to wear and tear. Maintenance and calibration are crucial to ensure optimal functionality and accuracy.
The Acu-Rite 2001003 digital readout is a precision measuring tool commonly used in industrial settings for accurate measurement and display of linear distances. It features a high-resolution display with customizable settings for different measurement units and reference points. Typical failures of the Acu-Rite 2001003 digital readout include display malfunctions such as dim or flickering screens, unresponsive keys, or erratic readings due to internal electronic component issues. Repairs involve diagnosing and replacing faulty components such as LEDs, keypads, or control circuits to restore the unit's functionality.
The Acu-Rite D200 digital readout unit is designed to provide accurate measurement and display of various machine tool movements in industrial applications. It features a high-resolution LCD display, multiple axis support, and various measurement functions such as absolute/incremental positioning and inch/metric conversion. Typical failures in the Acu-Rite D200 digital readout unit may include display malfunctions, erratic readings, communication errors, or power supply issues. These failures can be often attributed to internal component failures like the display panel, processor, or communication modules. Proper diagnostics and replacement of faulty components are essential in restoring the functionality of the unit.
The DRO (Digital Readout) unit, specifically the Acu-Rite 96060142 model, is a device used in industrial machinery to precisely display measurements and movements in real-time. It features a high-resolution digital display, easy-to-use interface, and compatibility with various sensors and encoders. Typical failures include display malfunctions, input/output errors, and power supply issues. Maintenance involves regular calibration, sensor checks, and component replacements as needed.
The Acu-rite 2xmill D200 2001003 CNC machine in the warehouse is exhibiting unusual behavior - it is not functioning as it normally does.β Purchase or Repair:β‘οΈ Reply Acu-rite
The Acu-rite 2xmill D200 2001003 CNC machine is not functioning as usual. It seems to be acting abnormally, but Im uncertain about the specific issue.β Purchase or Repair:β‘οΈ Reply Acu-rite
The Acu-rite 2xmill D200 2001003 CNC machine is displaying abnormal behavior in the warehouse.β Purchase or Repair:β‘οΈ Reply Acu-rite
The Acu-rite 2xmill D200 2001003 on the CNC machine is experiencing issues with the spindle not functioning properly, causing significant delays in production. Please respond urgently to address this critical matter and get our line back up and running swiftly.β Purchase or Repair:β‘οΈ Reply Acu-rite
Im experiencing some issues with the Acu-Rite D200 2001003 monitor. It seems like something is not working correctly, but Im not exactly sure what the problem is. Your assistance in resolving this matter would be greatly appreciated. β Purchase or Repair:β‘οΈ Reply Acu-Rite
The linear scale on the Acu-Rite Companies ENC 125T 557970-78 is malfunctioning, causing a significant disruption to our production line. Urgent repair service is required to minimize downtime and ensure smooth operations. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Experiencing screen display issues on the Acu-Rite D200 2001003 monitor unit, seeking technical assistance. Need urgent repair to resume normal operations. Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Im experiencing a problem with the Acu-Rite D200 2001003 screen monitor. There seems to be an issue with the functionality, and Im unsure whats causing it. Your assistance in resolving this would be greatly appreciated. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Repair Inquiry for Acu-Rite Linear Scale ENC 125T 557970-78Hello,I am a vendor representing a client with an Acu-Rite Linear Scale ENC 125T (Part Number 557970-78) that requires repair. Could you please provide information on the repair process and cost estimation for this specific model?Your β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Could you please provide me with pricing and availability details for the Acu-Rite D200 2001003 Screen Monitor? I am looking to source one quickly and would appreciate your assistance. Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Hello, Im interested in purchasing an Acu-Rite Companies ENC 125T 557970-78 Linear Scale. Could you please provide information on pricing and availability? Im looking to source one quickly. Thank you! β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Do you have an Acu-Rite Companies ENC 125T 557970-78 Linear Scale available for sale or for repair? Our unit is down, and were in need of assistance to keep production running smoothly. Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Could you please confirm if the Acu-Rite D200 2001003 Screen Monitor is still supported, or if replacement parts are available for it? Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Can you please confirm if you have the Acu-Rite D200 2001003 Screen Monitor in stock for sale? Our unit is down, and we need to keep production running. β Purchase or Repair:β‘οΈ Reply Acu-Rite
My Acu-Rite Companies ENC 125T 557970-78 Linear Scale needs repair. Looking for a reliable technician to fix it β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
We experienced downtime on the Acu-Rite Companies ENC 125T 557970-78 linear scale unit earlier today due to a malfunction. Could you please provide an update before the next shift arrives? β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Hello, I am interested in purchasing the Acu-Rite Companies ENC 125T 557970-78 Linear Scale. Could you please provide me with information on pricing and availability? I am looking to source this unit quickly. Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The Acu-Rite ENC 125T 557970-78 is displaying error code 4C. The linear scale is not responding and causing inaccuracies during operation. Please advise on the necessary steps to troubleshoot and resolve the issue. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The Acu-Rite D200 2001003 Screen Monitor in the shop is not working. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Hey, the Acu-Rite D200 2001003 screen monitor went down mid-shift. Please check it out first thing in the morning. Thanks! β Purchase or Repair:β‘οΈ Reply Acu-Rite
Im experiencing some issues with my Acu-Rite Companies ENC 125T 557970-78 linear scale, something seems to have stopped working, but Im not exactly sure what. Your assistance would be greatly appreciated. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Acu-Rite D200 monitor at Machine 5 just had a drive or board failure. Need immediate repair or replacement. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Hi there, could you please provide me with pricing and availability information for the Acu-Rite D200 2001003 Screen Monitor? Im trying to source one quickly and want to ensure its the right model. Thank you! β Purchase or Repair:β‘οΈ Reply Acu-Rite
The Acu-Rite Companies ENC 125T 557970-78 linear scale is showing error code E12, unable to calibrate properly. Need assistance ASAP to get equipment back up and running. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The linear scale drive or board on the Acu-Rite ENC 125T 557970-78 just failed. Ill need to troubleshoot and replace it ASAP to prevent any production delays. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The screen monitor on our Acu-Rite D200 2001003 is malfunctioning and affecting the production line. Urgent repair service needed to resolve the issue β Purchase or Repair:β‘οΈ Reply Acu-Rite
The Acu-Rite D200 2001003 screen monitor is displaying erratic behavior by flickering and showing distorted images intermittently. β Purchase or Repair:β‘οΈ Reply Acu-Rite
The Acu-Rite D200 2001003 screen monitor unit is displaying abnormal behavior by flickering erratically and displaying distorted images intermittently. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Please provide an update on the status of my Acu-Rite D200 2001003 unit (Screen Monitor). It is still down and needs attention. Your β Purchase or Repair:β‘οΈ Reply Acu-Rite
Hi, can you provide details on servicing an Acu-Rite D200 2001003 Screen Monitor? My client is experiencing issues with it. Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Hello, I am interested in purchasing an Acu-Rite Companies ENC 125T 557970-78 Linear Scale. Could you please provide information on pricing and availability? I am looking to source one quickly. Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The Acu-Rite ENC 125T linear scale on Machine 5 malfunctioned halfway during the night shift. Please address the issue ASAP in the morning. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The Acu-Rite Companies ENC 125T 557970-78 linear scale unit in the shop isnt working. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The Acu-Rite Companies ENC 125T 557970-78 is a Linear Scale unit that isnt working properly. Please investigate and address the issue β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
the Acu-Rite D200 2001003 screen monitor went down mid-shift. Please have a tech check it out first thing in the morning. Thanks. β Purchase or Repair:β‘οΈ Reply Acu-Rite
The Acu-Rite D200 2001003 Screen Monitor unit experienced downtime earlier today during the morning shift. Can you provide insights on what caused the issue and when it happened? The next shift will be starting soon, and we need to address this quickly. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Could you please provide troubleshooting steps and repair options for the Acu-Rite D200 2001003 Screen Monitor? My client is experiencing issues with this product. Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite
Hello, I need help with the Acu-Rite D200 2001003 Screen Monitor unit. It caused downtime. Can you provide a quick explanation of what happened and when it occurred? Thank you. β Purchase or Repair:β‘οΈ Reply Acu-Rite
The screen on our Acu-Rite D200 2001003 monitor is malfunctioning, affecting the production line. Its urgent that we get this repaired immediately to minimize downtime. β Purchase or Repair:β‘οΈ Reply Acu-Rite
The Acu-Rite Companies ENC 125T 557970-78 is showing error code E26. Machine not moving along X axis. Need urgent assistance to troubleshoot and resolve the issue. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The Acu-Rite Companies ENC 125T 557970-78 linear scale unit is malfunctioning. It appears to be behaving unusually and not operating as expected in the warehouse. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Hi, we have an Acu-Rite D200 2001003 screen monitor that isnt working. Were looking for repair information. Can you provide assistance or recommend a repair shop? Thanks! β Purchase or Repair:β‘οΈ Reply Acu-Rite
The Acu-Rite Companies ENC 125T 557970-78 linear scale is not reading the correct measurements, halting production. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
The Acu-Rite Companies ENC 125T 557970-78 Linear Scale unit is not working. β Purchase or Repair:β‘οΈ Reply Acu-Rite Companies
Acu-Rite D200 2001003 screen monitor down. Drive or board failure, needs urgent repair. β Purchase or Repair:β‘οΈ Reply Acu-Rite
We are experiencing consistent errors with the temperature sensors on the Acu-Rite 387575200, resulting in inaccurate readings and disrupting the production line. Urgent repair needed to prevent further delays and ensure line efficiency.β Purchase or Repair:β‘οΈ Reply Acu-Rite
I have an Acu-Rite 2001003 that needs repairing. Its displaying an error message and not functioning properly. Need assistance as soon as possible.β Purchase or Repair:β‘οΈ Reply Acu-Rite
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.