Aerobics Inc specializes in designing and manufacturing high-efficiency air filtration systems for industrial applications. Their products are known for their innovative designs, superior performance, and reliability in maintaining clean air quality in various industrial settings. [AI]
We repair a wide range of Aerobics Inc Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Pacemaster PWM Processor, model 9501002 by Aerobics Inc., is a crucial industrial electronic component used in various applications that require precise control of motors, such as in industrial automation and robotics. This unit utilizes Pulse Width Modulation (PWM) technology to regulate the speed and direction of motors efficiently. Typical features include high-frequency PWM output, error detection mechanisms, and adjustable duty cycles for fine-tuning motor control. Common failures in this unit include malfunctioning PWM circuitry, overheating issues leading to component degradation, and errors in signal processing resulting in erratic motor behavior. Regular maintenance and monitoring are essential to prevent these failures and ensure optimal performance.
The Aerobics Inc. LDT-A06 is a control board used in industrial applications. It is designed to regulate the functions of a specific system or equipment. The board features various inputs and outputs for interfacing with other components, as well as microcontrollers for executing programmed functions. Common failures in the LDT-A06 board include malfunctioning transistors, capacitors, or damaged traces due to overheating or electrical surges. Regular maintenance and proper cooling can help prevent these issues.
The Aerobics Inc. 9501001 Treadmill Circuit Board is a crucial component in the operation of a treadmill system. It functions as the control center for various treadmill functions, such as speed control, incline adjustment, and monitoring of vital statistics like heart rate and distance covered. The circuit board is equipped with integrated circuits, capacitors, resistors, and other electronic components to facilitate smooth and accurate operation. Common failures in the Aerobics Inc. 9501001 Treadmill Circuit Board may include burnt out components due to electrical surges, damaged connectors, faulty ICs, or malfunctioning sensors. Proper troubleshooting and diagnostic skills are required to identify and rectify these issues efficiently to restore the functionality of the treadmill circuit board.
The Power Supply unit manufactured by Aerobics Inc., model 9501001, is designed to convert electrical power from a mains source into a form suitable for powering industrial electronic devices. It features multiple output channels with various voltage and current ratings to accommodate different components. Typical failures in this power supply unit may include capacitor degradation, voltage regulation issues, and power surges leading to component failures. Regular maintenance and monitoring of the unit are recommended to prevent unexpected downtime and equipment failures.
The PaceMaster Pro Series circuit board, model number Aerobics Inc 9501001, is designed for use in industrial exercise equipment such as treadmills. This circuit board is responsible for controlling and monitoring the various functions of the treadmill, including speed, incline, and workout programs. It features a microprocessor for data processing, memory storage for program settings, and interface components for user input and display output. Typical failures of the PaceMaster Pro Series circuit board include damage to the microprocessor due to power surges or overheating, memory corruption leading to erratic behavior, and issues with the interface components such as worn-out buttons or faulty display connections. Repairing these failures may involve replacing damaged components, reprogramming the memory, or troubleshooting the interface connections.
The Aerobics Inc 9501001 board is a critical industrial electronic component used in various applications for signal processing and control functions. It features a high-quality construction, compact design, and compatibility with standard industrial interfaces. Common failures in this board may include component burnout, solder joint issues, and connector failures due to environmental factors or electrical stresses. Repair typically involves troubleshooting at the component level, replacing faulty parts, and ensuring proper connections for optimal performance.
The Aerobics Inc Pacemaster ProPlus 2 display board is an essential component used in treadmills for monitoring and displaying important workout information to the user. It features a clear and bright LED display that typically shows speed, distance, time, and other relevant data during exercise. Common failures in display boards can include display malfunctions such as missing segments, flickering, or total screen failure, which can be caused by faulty connections, damaged components, or aging displays. Additionally, power supply issues, such as voltage fluctuations or faulty capacitors, can also contribute to display board failures in industrial settings. Repairing such issues requires troubleshooting the circuitry, replacing faulty components, or recalibrating the display module for optimal performance.
The Aerobics Inc. 9501001 Power Supply unit is designed to convert input voltage into a stable output voltage suitable for various industrial applications. It features high efficiency, multiple output voltages, and overcurrent/overvoltage protection. Typical failures include blown fuses, defective capacitors, and damaged transformers due to power surges or overloading. Regular maintenance and monitoring of input/output voltages can help prevent failures and ensure continuous operation.
The Aerobics Inc. J0311029-2 treadmill board is a critical component used in commercial or industrial-grade treadmills. Its primary purpose is to regulate and control the speed, incline, and other functions of the treadmill. Key features of this board may include a microcontroller for processing user inputs, motor control circuits for regulating the treadmill's speed, and safety features such as emergency stop functionality. Additionally, it may have built-in diagnostics for troubleshooting issues. Typical failures of the Aerobics Inc. J0311029-2 treadmill board may include issues with the power supply, faulty motor control circuits leading to erratic speed control, or malfunctioning safety features. Overheating due to prolonged usage or electrical surges can also contribute to the failure of components on the board. Regular maintenance and inspection can help prevent such failures.
The Treadmill Power Supply model 9501001 by Aerobics Inc. is designed to convert incoming AC voltage to the required DC voltage for powering the treadmill's motor and control circuitry. It features overcurrent protection, short circuit protection, and voltage regulation capabilities to ensure stable and safe operation of the treadmill. Typical failures include blown fuses, damaged capacitors, burnt components, and faulty voltage regulators. Regular maintenance and inspection can help prevent these failures and ensure the longevity of the power supply unit.
: My PaceMaster Pro Series Aerobics Inc. has stopped working entirely. The circuit board appears to have malfunctioned, as the unit no longer powers on and doesnt respond to any input. As it is a commercial-grade model, Im concerned about the potential costs associated with repair versus replacement. Based on my past experience, replacing the entire circuit board could cost between $1500-$2000 depending on availability and expertise required. However, without a formal diagnostic assessment of the unit, its difficult to provide an accurate estimate for a repair.:β‘οΈ Reply Aerobics Inc
Hi there, the Aerobics Inc. 9501001 is displaying a Power Supply Failure error message and is completely unresponsive. We tried resetting the equipment, but it still wont turn on. Need assistance ASAP.β‘οΈ Reply Aerobics Inc