Bindicator is a reputable manufacturer in the industrial sector, specializing in level measurement technologies for silos, tanks, and vessels. Their advanced sensors and control systems help businesses accurately monitor and manage material levels for optimal efficiency and safety. [AI]
We repair a wide range of Bindicator Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Bindicator LRF130144-C-DL-2-130145-B is a level sensor used in industrial applications to measure the level of material in tanks or silos. This model features a rugged construction suitable for harsh environments, a range of communication options including Modbus and HART protocols, and a high accuracy level measurement system. Common failures include sensor malfunction due to environmental factors, communication errors, or mechanical issues. Regular maintenance and calibration are essential to ensure reliable operation.
The Bindicator PD1-A-0-L12-G1A is a point level sensor designed for measuring the presence or absence of material in a bin, tank, or silo. This ultrasonic level switch features a 1-inch NPT process connection, a 0-30 ft. measuring range, and a 4-20 mA analog output. Common failures in this model include sensor fouling, electrical faults, and inaccurate level readings due to environmental factors. Regular maintenance and cleaning are essential for optimal performance.
The Bindicator lrf130035-s is a level sensor designed to accurately measure level of solid or liquid materials in industrial tanks or silos. It uses laser technology to provide precise level measurements and is equipped with a self-cleaning mechanism to maintain accuracy in dusty environments. Common failures include sensor misalignment, electronic component malfunctions, and power supply issues. Regular maintenance and calibration are recommended to ensure optimal performance.
The Bindicator ULMS 5 BD Assy is a level monitoring system used in industrial applications to provide precise measurements of material levels in tanks or silos. This device features high accuracy in level detection and is equipped with a durable design to withstand harsh industrial environments. Typical failures of the Bindicator ULMS 5 BD Assy may include sensor malfunctions, communication errors, or power supply issues. Regular maintenance and calibration are essential to ensure the accurate performance of this level monitoring system.
The Bindicator LHY200260 is a point level switch that is used in industrial applications to detect the presence or absence of material in a silo, hopper, or other vessel. It features a compact design, easy installation, and is suitable for various types of materials such as powders, pellets, and granular substances. Typical failures of the Bindicator LHY200260 may include issues with the sensor probe such as build-up of material causing false readings, electrical connection problems, or failure of the control unit resulting in inaccurate level detection. Regular maintenance and calibration are recommended to ensure reliable operation.
The Bindicator Lby233119-1 is a level sensor commonly used in industrial environments to measure the level of solids or liquids in tanks or silos. It utilizes a mechanical paddle that is suspended in the material being measured. As the level changes, the paddle is rotated, activating a switch that sends a signal to a control system. Typical failures of the Bindicator Lby233119-1 include motor or paddle malfunctions, switch failures, and signal transmission issues. These failures can result in inaccurate level readings or complete sensor failure. Regular maintenance and calibration are recommended to ensure accurate and reliable operation.
The Bindicator Lar131431 is a level sensor used for measuring the level of materials in industrial silos, bins, and hoppers. It features a rugged design suitable for harsh industrial environments, with a stainless steel construction and a high-temperature-resistant cable. Common failures in the Bindicator Lar131431 may include sensor damage due to material buildup or mechanical stress, cable damage causing signal loss, or electronic component failure leading to inaccurate readings. Regular maintenance and cleaning can help prevent these failures and ensure accurate level measurements.
The Bindicator 2200 is a level sensor widely used in industrial applications to accurately measure and monitor material levels in silos, tanks, and vessels. It features a robust design with an advanced electromechanical system that provides reliable and precise level readings. Typical failures in the Bindicator 2200 may include sensor malfunctions, electrical faults, or mechanical wear due to prolonged use in harsh environments. Regular maintenance and calibration are essential to ensure optimal performance and accuracy in material level measurements.
The BINDICATOR LAR131431 controller is designed for level control in industrial applications. It features a compact design, simple installation, and intuitive operation interface. Typical failures include power supply issues, sensor malfunctions, and communication errors. Proper maintenance and regular calibration can help prevent these issues.
The BINDICATOR LBY233119-I is a readout unit commonly used in industrial settings to display and monitor measurements from sensors and transmitters. It features a clear LCD display for easy visibility, multiple input options for different signal types, and user-friendly interface for configuration and calibration. Typical failures of the BINDICATOR LBY233119-I include screen malfunctions, signal input errors, and power supply issues. These failures can be caused by internal component damage, overheating, or water ingress. Regular maintenance and proper handling can help prevent these issues and ensure reliable operation.