Bycan Systems is a manufacturer specializing in advanced battery charging solutions for industrial applications. They are known for their innovative battery chargers that optimize charging efficiency and prolong battery life in demanding operational environments. [AI]
We repair a wide range of Bycan Systems Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Bycan Systems BA-14/28-50P is a power supply and charger unit designed for industrial applications. Its primary purpose is to provide reliable power to critical equipment while also charging backup batteries. Key features of the BA-14/28-50P include dual 14V and 28V output voltage options, a maximum output current of 50A, and a robust design suitable for harsh industrial environments. The unit is equipped with overcurrent and overvoltage protection, ensuring the safety of connected devices. Common failures of the Bycan Systems BA-14/28-50P include blown fuses, faulty voltage regulation components, and damaged input/output connectors. Regular maintenance and inspection can help prevent these issues and ensure the continued functionality of the power supply and charger unit.
The Blue Angel Battery Charger, model BA-14/28-50 by Bycan Systems, is designed to charge lead-acid batteries in industrial applications. This charger provides a charging output of 14 or 28 volts DC at a current rating of 50 amps. The unit is equipped with features such as overcharge protection, reverse polarity protection, and short circuit protection to ensure safe and efficient charging of batteries. Typical failures in this device include blown fuses, faulty output diodes, and damaged control circuits. Regular maintenance and periodic inspection can help prevent these failures.
The Bycan Systems RB-14/28-25P is a battery charger designed for industrial use. It is capable of charging 14 to 28 volts batteries with a maximum current output of 25 amps. This charger is highly efficient and reliable, featuring a rugged construction suitable for harsh industrial environments. Typical failures in this model may include issues with the charging circuitry, thermal management system failures, or problems with the display/control module. Regular maintenance and monitoring of the charging parameters can help prevent potential failures and ensure optimal performance of the battery charger.
The Bycan Systems RB-14/28-25P Aircraft Power Supply is designed to provide stable and reliable power to various electrical systems in an aircraft. It features a voltage output of 28 volts and a current output of 25 amps, making it suitable for a range of applications within an aircraft. Common failures in this power supply include component burnout due to overheating, capacitor issues, and voltage regulation problems. Regular maintenance and monitoring of the power supply can help prevent these failures and ensure optimal performance.
The Ground Power Unit Bycan Systems RB-14/28-25 is designed to provide electrical power to aircraft on the ground to start their engines and operate onboard systems. It features a voltage output of 28 VDC and a current output of 25 amps, allowing it to meet the power requirements of a wide range of aircraft. Typical failures in Ground Power Units like the RB-14/28-25 may include issues with the power output, such as unstable voltage levels or insufficient current delivery. Other common failures can include overheating due to prolonged or excessive use, as well as internal component failures such as damaged wiring or faulty connectors. Regular maintenance and electrical testing can help prevent these failures and ensure the reliable operation of the unit.
The Bycan Systems PS-2850A is a battery charger utilized in industrial settings to provide reliable and efficient charging for various types of batteries. This model features a high-power output capability of up to 2850 amps, enabling rapid charging of large capacity battery banks. Common failures in battery chargers include issues with the charging circuitry, thermal management system failures, and component degradation over time affecting charging efficiency. Regular maintenance and periodic inspections are recommended to ensure optimal performance and longevity of the battery charger.
The Bycan Systems PS-2850 is a power supply unit designed for industrial applications. Its primary purpose is to convert input voltage from AC to DC, providing a stable and regulated power output to various electronic devices within a system. The unit features overload protection, short-circuit protection, overvoltage protection, and overtemperature protection mechanisms to ensure safe and reliable operation. Typical failures of the Bycan Systems PS-2850 include component degradation due to prolonged use, overheating leading to damage, and failure of protection circuits resulting from power surges or electrical faults. Regular maintenance and monitoring of input and output parameters can help prevent potential failures and ensure the longevity of the power supply unit.
The Bycan Systems RB-14/28-25 is a battery charger designed for industrial applications. It is specifically tailored for charging 14-cell lead-acid batteries with a voltage of 28V at a maximum charge rate of 25A. This battery charger features a compact design, high efficiency, and reliable performance. Typical failures in this battery charger may include blown fuses, faulty rectifier diodes, damaged capacitors, or malfunctioning control circuitry. It is recommended to check and replace these components as necessary to ensure proper functioning of the battery charger.
The Bycan Systems RB-142825 is a battery charger designed for industrial applications. It features a multi-stage charging process, temperature compensation, and adjustable charging parameters. Typical failures include internal component issues leading to failure to charge or overcharging batteries, as well as problems with the display or control circuitry. Regular maintenance and calibration are recommended to ensure proper charging performance.
The Red Baron Power Unit by Bycan Systems is a power supply unit designed for industrial applications. It features a 14VDC/28VDC dual output with a maximum output current of 25 amps. This power unit is commonly used in aviation and automotive industries for powering onboard systems and equipment. Typical failures include blown fuses, component degradation, and power output fluctuations due to aging components or overheating. Regular maintenance and inspection are recommended to ensure optimal performance and longevity.
Certainly! Please provide me with more details about how the unit is behaving strangely. This will help me better understand the issue and provide you with the appropriate troubleshooting steps.โก๏ธ Reply Bycan Systems