We repair a wide range of Cincinnati Equipment.
Ask questions, or call 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Cincinnati Inc 3-351-3912a is a servo drive unit commonly used in industrial automation applications. This model is designed to control the speed and position of a servo motor accurately. It features high precision control algorithms, multiple communication interfaces, and robust construction for reliable operation in harsh industrial environments. Typical failures of the Cincinnati Inc 3-351-3912a include power supply issues, faulty components such as capacitors or resistors, and communication errors. Regular maintenance and testing are recommended to ensure optimal performance and early detection of potential failures.
The Cincinnati Inc 826833 84044 is a model of industrial laser cutting machine. This device is designed for high precision cutting of metal sheets and other materials in industrial applications. It features a powerful laser source, a precise motion control system, and a user-friendly interface for programming and operation. Common failures in the Cincinnati Inc 826833 84044 model include issues with the laser source such as power fluctuations or tube degradation, problems with the motion control system like encoder malfunctions or servo motor faults, and issues with the cooling system leading to overheating or damage to components. Proper maintenance and timely calibration are crucial to ensure optimal performance and prolong the lifespan of the machine.
The Cincinnati Milacron 3-4244-2132a is a motor controller commonly used in industrial machinery. Its primary purpose is to control the speed and torque of electric motors, providing precise control over various industrial processes. This model features a robust design with advanced circuitry for reliable operation in harsh industrial environments. It includes protection features such as overcurrent and overvoltage protection to safeguard the connected motor and equipment. Typical failures of the Cincinnati Milacron 3-4244-2132a include blown fuses, damaged power transistors, and malfunctioning control circuits. These failures can lead to erratic motor behavior, loss of speed control, or complete motor shutdown. Regular maintenance and proper installation practices can help prevent these issues and prolong the lifespan of the motor controller.
The Cincinnati Milacron mila-3-424-1994a is a servo drive used in industrial machinery for precise control of motor speed and positioning. It features advanced servo control algorithms, high-resolution encoder feedback, and communication interfaces for seamless integration with other automation systems. Typical failures in this servo drive include power supply issues, blown fuses, faulty output transistors, and encoder feedback errors. These failures can result in poor motor performance, erratic movements, or complete loss of control. Troubleshooting such issues may involve checking power supply voltages, replacing damaged components, or recalibrating the encoder feedback system.
The Cincinnati 3-542-1079a model is a servo drive used in industrial machinery for precise control of motion and speed. It features sophisticated feedback mechanisms, high-resolution encoders, and advanced signal processing capabilities. Typical failures include power supply issues, component degradation, and communication faults, which can result in erratic behavior or complete malfunction of the drive. Troubleshooting involves thorough testing of power circuits, encoder signals, and communication protocols to identify and address the root cause of the failure.
The Cincinnati Milacron 3 531 3323A-3 531 3299A is a power supply module used in industrial electronic systems. Its primary function is to convert incoming AC power to the required DC voltage levels for the electronic components on the system. The module features a robust design for reliable performance in harsh industrial environments. Common failures in this module include blown fuses, capacitor degradation, and power transistor failures. These failures can result in loss of power output, erratic behavior, or complete system shutdown. Regular maintenance and inspection of the power supply module are recommended to prevent unexpected failures and ensure smooth operation of the industrial electronic system.
The Cincinnati Milacron 3-533-0461g is a servo drive used in industrial machinery for precise control of motor speed and position. It features a robust design, high-performance capabilities, and compatibility with various motor types. Typical failures include burnt power components, encoder feedback issues, and communication errors. Repairing these failures involves component level troubleshooting, replacement of faulty parts, and recalibration of the drive.
The Cincinnati Encoder is a rotary encoder commonly used in industrial applications to convert mechanical motion into electrical signals. It typically features high precision, durability, and reliable performance. Common failures include damage to the encoder disk, signal distortion due to electrical interference, and wear and tear on internal components. Regular maintenance and proper installation are recommended to ensure optimal functionality.
The Cincinnati Milacron 3-531-4000a is a PLC (Programmable Logic Controller) module used in industrial automation systems. Its main purpose is to control and monitor various processes in manufacturing environments. This model features multiple digital inputs and outputs, as well as analog input and output channels for precise control of equipment. Common failures include power supply issues, communication errors, and component failures due to environmental factors such as temperature fluctuations or electrical interference. Troubleshooting typically involves testing and replacing faulty components to restore the module's functionality.
The Cincinnati Milacron 3-424-1987a is a servo drive designed for industrial applications requiring precise control of electric motors. This model features advanced control algorithms for accurate speed and position control, as well as the ability to handle high current and voltage levels. Common failures in this servo drive include issues with the power supply, failed capacitors, faulty control boards, and overheating due to poor ventilation. Regular maintenance and monitoring of this equipment are recommended to prevent costly downtime.
We use Touch view graphic flat panel of Cincinnati dynacomp. Inc.(Item #1007410107 Rev.C, Model # 7000-ST-E256, Lot #40524180, Serial #6508610021)We want to buy new graphic flat panel set.Would you like to send me the contact point of yours or cincinnati dynacomps. (E-mail or Fax. No. - I want to contact through e-mail only)β‘οΈ Reply Cincinnati Dynacomp
HELO,WE HAVE A CNC CINCINATI MILACRON MAXIM 500 MACHINE WITH ACROMATIC 950 CONTROLWE ARE LOCKING FOR CPU 3-533-0346G USED,AND OUR QUESTION IS IF WE CAN FIND IT IS POSIBLE CHANGE THE CPU FOR 3-424-2026ATHANKSHalcom Internationalβ‘οΈ Reply Cincinnati Milacron
machine is arrow 1000. starts up until and says keypad touch screen missing. any suggestions?β‘οΈ Reply Cincinnati Milacron
Cindy Dase wrote machine is arrow 1000. starts up until and says keypad touch screen missing. any suggestions?Cindy,Have you been able to locate the problemEdβ‘οΈ Reply Cincinnati Milacron
Problem or Bad IO CHMD + CMHD AND AXISSERVO DV5β‘οΈ Reply Cincinnati Milacron
Dear Sir5:We have a Cincinati CNC machine using Acromatic 2100 control system.The machine has started to boot under DOS, then Windows NT4.0 has been loaded. It then load Vicker software and the monitor color changed to pink stripe. We can see nothing but the pink striped monitor thereafter. I am not sure this is touch screen monitor problem or video card problem. Could you please let me know your opinion and thought. Thanks!Douglasdyeh@pantronix.comβ‘οΈ Reply Cincinnati Milacron
Dear Sir,We have cincinatti milacron cnc turning centre on our machine monitor is indicating that X axis HDRW Diagnotics fail Alert code is 00453. Pls send our reply for the sameRegards,Ind-Tech Engineering,Ph 001-0836-4265858, 019880261326HUBLI-580 030 (Karnataka State) INDIAβ‘οΈ Reply Cincinnati Milacron
Hello;We have a number of Cincinnati Milacron Camac lcd screens that are in need of repair.These screens are on injection molding machines of late 80s vintage. The Camac was the latest control at the time. The screens are yellow lettering on a black backround. Currently we are able to read only parts of the text. We have had no luck through CM and have had little success with local repairs.Can you help us?Tom FellbergMaintenance ManagerCommercial Plastics Co.Mundelein IL.847-566-1700 EX 234tomf@ecommercialplastics.comβ‘οΈ Reply Cincinnati Milacron
We are the largest tyre and rim manufacture and exporter in sri Lanka. We use many machines in our production line.We have CINCINNATI MILACRON β SABER 500 CNC vertical machining centre. But unfortunately it have a problem.Z Axis moving Down During Power cut upto 5mm. Z Axis have the Break Motor & No counter Balance. We changed the New Break also. Problem not solved.The Drive is CINCINNATI MILACRON BDS4.Please help me for solve this problem.I have sent here with the all data of the motor. Please check the details of motor . Goldline brushless P.M ServomotorModel 1-604-0222Serial No 96E 414W-564Can I change the X axis servo drive and Z axis Drive for check the drive?. If possible what are the settings of drives.β‘οΈ Reply Cincinnati Milacron
I am trying to find the operators and set-up manual for a vickers bds4210-23414w32. any help would be great.Thanksβ‘οΈ Reply Cincinnati Milacron
We have a bunch of Cincinnati Milacron electronics we striped out of a Sabre, 2100, 750 and an arrow 500 VMCsLet me know and Ill send you picturesβ‘οΈ Reply Cincinnati Milacron
Machine is displaying error code 35313564a, causing production downtime.β‘οΈ Reply Cincinnati
Im presently looking for a wiring diagram for a Cincinnati milacron milling machine. MODEL#-LL, Procuct#-315-16 plain dial type, Serial#-3104PT8-0015, ACVOLT-460, PH-3, HZ-60, Control diagrams-F-314290. Any information you can provide would be greatly appreciated.Thanks,Brian Petitβ‘οΈ Reply Cincinnati Milacron
Im looking for a electrical diagram for a Cincinnati Milacron machine.Best regards,Miroslav Petkovβ‘οΈ Reply Cincinnati Milacron
HI!Im looking for a quote on repair of a power supply unitfor a CINCINNATI MILACRON ARROW750If there is something you can help me Illapreciatethanksluisβ‘οΈ Reply Cincinnati Milacron
Dear Sir,IN our cnc machine we use cincinnati milacron bds4 drives.But in sudden power cut Z Axis drop few mm down without any alarm. could you please tell us whether this is a fault of axis drve or can we adjust any nob (balance , stability or current limit) to overcome this problemβ‘οΈ Reply Cincinnati
Sir, We bought a used Cincinnati Arrow 2000 machine with TNC 426 Control. We want to start the machine . As we do not have any Electrical manuals and Drive manuals we are stuck at some errors . We need drive BDS4 service manual and Electrical manusl to resolve our problems . pl. help to start our machine . At immediate help pl. let us know What would be the problem as drive shows error of Under Voltage . Please suggest some remedies.Thanks & regards ,Bipinβ‘οΈ Reply Cincinnati
Hello, I have a cincinnati milacron Lathe with a VFS5 275/2604A-10 Spindle drive, do you repair these drives? what would the average cost be to do so. Thanks YouMarkβ‘οΈ Reply Cincinnati Milacron
HIWe have a VFS5-275-00-2604A VICKERS DRIVER.with the MOTION LINK PLUS SOFTWARE appears a error No 18 BAD TL. but the boars are the same that we used before.We need the password to unblocked the software to reinstall the TL file, that we have. The TL file that we have is VFS5 v 1.03cC with a compensation Board 275/2604a-010.The encrypted key number for the LOCK SMITH COMMAND is 1991923109β‘οΈ Reply Cincinnati Milacron
The part number is 840777/I and could you provide a price estimate.β‘οΈ Reply Cincinnati Milacron
Cincinnati Milacron 3 531 2204a unit not powering on. Need immediate repair assistance.β‘οΈ Reply Cincinnati Milacron
Based on my experience, Ive seen similar issues with the CINCINNATI MILACRON 3-533-0780G GCPU. The common symptoms typically involve erratic system behavior, frequent error messages, and potential communication failures. These could indicate a variety of potential issues, including software glitches, hardware malfunctions, or power supply problems. I recommend further inspection by a qualified technician to pinpoint the exact cause of the problem.β‘οΈ Reply CINCINNATI MILACRON
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)