Welcome to Cutler

Cutler is a manufacturer renowned for their precision-engineered cutting tools and equipment used in metal fabrication and machining applications. They are known for their durable saw blades, drill bits, and milling cutters that ensure high efficiency and accuracy in industrial processes. [AI]

We repair a wide range of Cutler Equipment.

Ask questions, or 1-336-969-0110 for faster service.

Use the search bar above to find specific manufacturers.


Why to send us your work?

To receive more information about your Cutler industrial electronics unit, please contact us at 1-336-969-0110. We offer testing, refurbishment, and extended warranty support for Cutler equipment. Our team of experts is here to assist you with any questions or concerns you may have.

πŸ› οΈ Common AI Repair Summaries 🏭

πŸ”§ Cutler Hammer af93ag0b005d(Unknown)

The Cutler Hammer af93ag0b005d is a solid-state overload relay designed for industrial motor protection applications. This device provides motor overload protection by monitoring the current flow and reacting to overcurrent conditions. It features adjustable current settings, phase loss protection, and diagnostic LEDs for easy troubleshooting. Common failures include internal component faults, overheating due to poor ventilation, and damage from power surges or electrical faults. Regular maintenance and proper installation can help prevent these issues and ensure the reliable operation of the overload relay.

  • Part: af93ag0b005d
  • Est. Repair Price: $4,006.00 (est.)
πŸ”§ Cutler Hammer hmcp250w5w(Unknown)

The Cutler Hammer HMCP250W5W is a thermal magnetic circuit breaker designed for use in motor protection applications. It features a thermal overload trip unit and a magnetic instantaneous trip unit which provides protection against both sustained overcurrent conditions and short-circuit faults. The 250A rating indicates its current carrying capacity, while the "W" suffix signifies that it is a molded case circuit breaker with a thermal-magnetic trip unit. Typical failures include tripping due to overload or short-circuit faults, contact wear leading to increased resistance, and mechanical failures such as broken springs or damaged trip mechanisms. Regular maintenance and testing can help prevent these failures and ensure reliable operation.

  • Part: hmcp250w5w
  • Est. Repair Price: $250.00 (est.)
πŸ”§ Cutler Hammer s801t24p3b(Unknown)

The Cutler Hammer S801T24P3B is a solid-state reduced voltage motor starter. It is designed to control the starting of electric motors by gradually ramping up the voltage to reduce the inrush current and mechanical stress on the motor. Key features of the S801T24P3B include a built-in overload protection for the motor, adjustable ramp-up time, and an advanced diagnostics system to help troubleshoot issues. Typical failures with this model include blown fuses, malfunctioning power semiconductors, and internal wiring faults. It is important to check for proper cooling, clean contacts, and connections when diagnosing issues with the Cutler Hammer S801T24P3B.

  • Part: s801t24p3b
  • Est. Repair Price: $6,052.00 (est.)
πŸ”§ Cutler Hammer mpc1m11(Unknown)

The Cutler Hammer MPC1M11 is a motor protection and control device utilized in industrial settings. It offers motor overload protection, phase loss protection, and phase unbalance protection. Additionally, it provides motor start functionality and can be used in various motor control applications. Common failures in the Cutler Hammer MPC1M11 include component wear leading to inaccurate protection settings, software glitches, and power supply issues. Regular maintenance and calibration are recommended to ensure proper functioning.

  • Part: mpc1m11
  • Est. Repair Price: $2,062.00 (est.)
πŸ”§ Cutler Hammer 15-1079-4(Unknown)

The Cutler Hammer 15-1079-4 is a solid-state motor controller designed for industrial applications. It is used to control the speed and direction of three-phase AC induction motors. This model features adjustable acceleration and deceleration rates, overload protection, and fault diagnostics. Typical failures include blown fuses, shorted power devices, and damaged control circuits due to power surges or electrical faults. Regular maintenance and proper installation are essential for maximizing the longevity of this device.

  • Part: 15-1079-4
  • Est. Repair Price: $3,408.00 (est.)
πŸ”§ Cutler Hammer 58-4305(Unknown)

The Cutler Hammer 58-4305 is a solid-state relay designed for industrial applications. It serves the purpose of switching high-power electrical loads with low control power input. Featuring reliable switching performance, minimal maintenance requirements, and fast response times, this solid-state relay is commonly used in motor control systems, heating systems, and other industrial applications. Typical failures of the Cutler Hammer 58-4305 include short circuits due to overloading, damage caused by voltage spikes, and failure of internal components such as the control circuitry. Regular inspection and preventive maintenance can help extend the lifespan of this device.

  • Part: 58-4305
  • Est. Repair Price: $888.00 (est.)
πŸ”§ Cutler Hammer 92-01950-00(Unknown)

The Cutler Hammer 92-01950-00 is a relay module commonly used in industrial control systems. It is designed to provide switchboard-level power distribution and control. This device features multiple relay channels, allowing for multiple control signals to be processed simultaneously. Typical failures of the Cutler Hammer 92-01950-00 include relay sticking, contact welding, and coil burnout. These issues can be caused by overloading, power surges, or poor maintenance practices. It is recommended to regularly inspect and clean the contacts, check for loose connections, and replace damaged components to prevent these failures.

  • Part: 92-01950-00
  • Est. Repair Price: $5,158.00 (est.)
πŸ”§ Cutler Hammer 66d2040g01(Unknown)

The Cutler Hammer 66d2040g01 is a power supply module typically found in industrial control applications. It is designed to convert incoming AC power into DC power suitable for driving various electronic components and devices within a control system. This model features a compact design, high reliability, and good efficiency. Typical failures of the Cutler Hammer 66d2040g01 include overheating due to clogged ventilation, component failures such as capacitors or diodes, and power surges that can damage internal circuitry. Regular maintenance and monitoring of input/output voltages and current levels can help prevent such failures.

  • Part: 66d2040g01
  • Est. Repair Price: $3,076.00 (est.)
πŸ”§ Cutler Hammer mpc1c22(Unknown)

The Cutler Hammer MPC1C22 is an industrial motor protection relay used to protect electric motors from overloads, phase loss, and phase imbalance. This relay features adjustable trip classes, programmable settings, and diagnostic LEDs for easy troubleshooting. Common failures with the MPC1C22 include power supply issues, relay contact failure, and programming errors. Regular maintenance and proper installation are crucial to ensure reliable operation of this motor protection relay.

  • Part: mpc1c22
  • Est. Repair Price: $2,796.00 (est.)
πŸ”§ Cutler Hammer 58-4332(Unknown)

The Cutler Hammer 58-4332 is a compact programmable logic controller (PLC) designed for industrial automation applications. It features a user-friendly interface, high processing speed, and a wide range of input and output options. Typical failures include power supply issues, communication errors, and overheating of components due to poor ventilation or excessive loads. Troubleshooting involves testing the power supply unit, checking connections, and verifying program logic.

  • Part: 58-4332
  • Est. Repair Price: $888.00 (est.)

Comments for Cutler

1 comments found.
πŸ“ Century For Trade &a said:
My CUTLER HAMMER D5OCRA14 QTECH ACCESS MODULE is displaying an error code and prevents the equipment from operating efficiently. Need assistance to diagnose and fix the issueβ€” Purchase or Repair:
➑️ Reply Cutler Hammer
πŸ“ noto said:
Im experiencing some issues with the Cutler-Hammer IQA 6400 P020709 meter. Im not entirely sure what it does, but something seems to have stopped working. Any guidance or support in troubleshooting this would be greatly appreciated. β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ Moritz said:
The Cutler-Hammer IQA 6400 P020709 meter is not working as reported. β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ Rosengarten said:
Can the Cutler-Hammer IQA 6400 P020709 meter be repaired or replaced? Im trying to check this off my to-do list. β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ Alex G. said:
the Cutler-Hammer IQA 6400 P020709 meter unit went down mid-shift. Please investigate and address the issue. Thanks! β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ jschauhan said:
The Cutler-Hammer IQA 6400 P020709 meter unit went down mid-shift. Please check and troubleshoot at the earliest during the day shift. Thank you! β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ Lieb said:
The Cutler-Hammer IQA 6400 P020709 unit is not working. It is described as a meter. β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ Luis Lerman Agudelo Bermudez said:
The Cutler-Hammer IQA 6400 P020709 meter is malfunctioning, affecting the production line. Urgently need repair service to address the issue to minimize downtime. β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ MANISH GANDHI said:
Cutler-Hammer IQA 6400 P020709 meter not displaying any readings. β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ Merturi said:
The Cutler-Hammer IQA 6400 P020709 meter is failing to provide accurate measurements, affecting the production line. Please address this issue immediately to resume operations smoothly. β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ saksena said:
The Cutler-Hammer IQA 6400 P020709 meter unit went down mid-shift. Kindly investigate and follow up. Thank you! β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ McGrath said:
Hello, I am inquiring about a repair for a Cutler Hammer S801T24N3S Starter that stopped working. The issue is currently unknown. Can you please provide information on the repair process and availability of replacement parts? Yourβ€” Purchase or Repair:
➑️ Reply Cutler Hammer
πŸ“ Samaniego said:
The Cutler Hammer HMCPE015E0C breaker seems to be malfunctioning, causing a halt in production. The line is down until this issue is resolved. Urgent repair service is needed to get things back up and running immediately.β€” Purchase or Repair:
➑️ Reply Cutler Hammer
πŸ“ ALEMU said:
Hello, Im interested in purchasing a Cutler-Hammer S801V50P3S power supply unit. I want to confirm if you have this model available and inquire about the pricing. I am in urgent need of sourcing one quickly. Thank you.β€” Purchase or Repair:
➑️ Reply Cutler-Hammer
πŸ“ Beaird said:
The Cutlerhammer 92-02024-00 is currently down due to unknown reasons. No error codes or alarms are displayed, but the equipment is completely non-responsive. Please advise on next steps for troubleshooting and repair.
➑️ Reply Cutlerhammer
πŸ“ MΓΈller said:
Cutler Hammer 1785K PMPP 1700 issue PanelMate Power Pro Operator Interface drive/board failed. Needs immediate attention!β€” Purchase or Repair:
➑️ Reply Cutler Hammer
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Contact Us

πŸš‘Shop LocationπŸ› οΈ

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
πŸš‘ Rush repair shipments only β€” no walk-ins.

πŸ“žPhone

1-336-969-0110

πŸ“¦Mailing AddressπŸš›

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
πŸ“¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.