Cutler-Hammer is a manufacturer known for their high-quality electrical components and control products for industrial applications. They specialize in producing circuit breakers, switches, and power distribution equipment designed to ensure safe and reliable operation in industrial settings. [AI]
We repair a wide range of Cutler-Hammer Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Cutler-Hammer S801T18N35 180 AMP Starter is a heavy-duty electrical device used to control the starting and stopping of industrial motors. Its main features include a high current rating of 180 amps, a rugged design for industrial environments, and advanced motor protection features such as overload protection and phase loss detection. Typical failures in this type of starter include contact welding, coil burnout, and failure of thermal overload relays due to excessive motor loads or power surges. Regular maintenance and periodic testing can help prevent these issues and ensure the reliable operation of the starter.
The Cutler-Hammer W200m3cfc/270501c202 is a motor control device used for managing and regulating the operation of industrial motors. It is designed to provide precise control over motor speed, direction, and torque. This model features robust construction, high durability, and reliable performance. Typical failures include contactor failure, capacitor issues, and circuit board malfunctions. Regular maintenance and timely replacements can help prevent these failures and ensure optimal performance.
The Cutler-Hammer D100TCM20 starter is designed for industrial motor control applications. It features a compact design, thermal overload protection, and easy installation. Typical failures include contactor welding, overload relay tripping, and damaged control circuit components. Careful inspection and testing are crucial to identify and resolve these issues effectively.
The Cutler-Hammer D100tcm20 is a solid-state overload relay designed for industrial applications. It features advanced motor protection and communication capabilities. Its purpose is to monitor motor current and provide overload protection to prevent damage to the motor. Typical failures may include internal component damage due to overcurrent conditions or communication interface issues. Regular maintenance and calibration are essential to ensure proper functioning.
The Cutler-Hammer S801V50P3S power supply unit is designed to convert electrical power into a form suitable for powering industrial electronic equipment. It features a constant voltage output of 24VDC with a rated current of 50A. This power supply unit is equipped with overload protection and short circuit protection mechanisms to ensure the safety and longevity of connected devices. Common failures include component degradation due to voltage spikes or excessive heat, leading to output voltage fluctuations or complete power failure. Regular maintenance and monitoring of input and output parameters can help prevent catastrophic failures.
The CUTLER-HAMMER D50 RAP10 Timer Counter Panel is a device designed for industrial applications to provide precise timing and counting functions. It features a digital display for easy monitoring and programming of timing parameters. Typical failures in the D50 RAP10 Timer Counter Panel may include display malfunctions, timer inaccuracies, or communication errors. These issues can often be resolved by troubleshooting the power supply, checking for loose connections, or replacing faulty components like resistors or capacitors.
The Cutler-Hammer IQA 6400 P020709 is a metering device used in industrial applications to measure electrical parameters such as voltage, current, power, and energy consumption. It features a digital display for easy readout and configuration settings for customization based on the specific requirements of the system. Typical failures in this device can include display malfunctions, accuracy issues due to sensor faults, and communication errors with other system components. Regular calibration and maintenance are essential to ensure accurate and reliable metering performance.
The CUTLER-HAMMER W200M3CFC / 270501C202 REGISTER ACCESS PANEL is a device used in industrial control systems to provide access to register data. It allows users to monitor and configure various parameters within control systems. This model features a user-friendly interface with display capabilities and keypad inputs for easy navigation. Typical failures of this device include malfunctioning display screens, unresponsive keypads/buttons, or communication errors between the panel and the control system. In some cases, power supply issues may also cause the device to fail. Regular maintenance and troubleshooting are essential to ensure the proper functioning of the CUTLER-HAMMER W200M3CFC / 270501C202 REGISTER ACCESS PANEL.
The Cutler-Hammer IQA 6400 P020709 meter is used in industrial settings for measuring electrical parameters such as voltage, current, and power consumption. It features high accuracy, a large display for easy reading, and various communication ports for data transfer. Typical failures in this meter include display malfunctions, communication errors, and accuracy drift due to component aging. Regular calibration and maintenance are recommended to ensure accurate measurements and prolong the lifespan of the device.
The Cutler-Hammer IQA 6400 IQ Analyzer is designed for use in industrial settings to monitor and analyze power quality. It is a sophisticated device capable of measuring various parameters such as voltage, current, power factor, and harmonic distortion. Features include a high-resolution display, data logging capabilities, and network connectivity for remote monitoring. Typical failures in the IQA 6400 may include power supply issues, display malfunctions, or communication errors. Proper maintenance and timely calibration can help prevent such failures in this crucial industrial electronics component.
Im experiencing some issues with the Cutler-Hammer IQA 6400 P020709 meter. Im not entirely sure what it does, but something seems to have stopped working. Any guidance or support in troubleshooting this would be greatly appreciated. β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
The Cutler-Hammer IQA 6400 P020709 meter is not working as reported. β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
Can the Cutler-Hammer IQA 6400 P020709 meter be repaired or replaced? Im trying to check this off my to-do list. β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
the Cutler-Hammer IQA 6400 P020709 meter unit went down mid-shift. Please investigate and address the issue. Thanks! β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
The Cutler-Hammer IQA 6400 P020709 meter unit went down mid-shift. Please check and troubleshoot at the earliest during the day shift. Thank you! β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
The Cutler-Hammer IQA 6400 P020709 unit is not working. It is described as a meter. β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
The Cutler-Hammer IQA 6400 P020709 meter is malfunctioning, affecting the production line. Urgently need repair service to address the issue to minimize downtime. β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
Cutler-Hammer IQA 6400 P020709 meter not displaying any readings. β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
The Cutler-Hammer IQA 6400 P020709 meter is failing to provide accurate measurements, affecting the production line. Please address this issue immediately to resume operations smoothly. β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
The Cutler-Hammer IQA 6400 P020709 meter unit went down mid-shift. Kindly investigate and follow up. Thank you! β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
Hello, Im interested in purchasing a Cutler-Hammer S801V50P3S power supply unit. I want to confirm if you have this model available and inquire about the pricing. I am in urgent need of sourcing one quickly. Thank you.β Purchase or Repair:β‘οΈ Reply Cutler-Hammer
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.