Exide is a manufacturer recognized for producing high-performance industrial batteries tailored for demanding applications in sectors like telecommunications, renewable energy storage, and material handling equipment. Their products are revered for their durability, reliability, and cutting-edge technology, ensuring uninterrupted power supply in critical operations. [AI]
We repair a wide range of Exide Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Exide 118302818 p1 is a battery charger designed for industrial use. It is equipped with advanced charging circuits to deliver precise and efficient charging to a wide range of battery types and sizes. Common failures in the Exide 118302818 p1 include issues with the charging circuitry, contact points, and cooling system. Proper maintenance and periodic inspection can help identify and address potential failures before they cause significant downtime.
The Exide 118-302-421 g is a battery charger commonly used in industrial applications. It is designed to charge lead acid batteries efficiently and safely. This model features multiple charging modes such as boost, equalization, and float, ensuring optimal charging for various battery types. Common failures in this model include power supply issues, such as blown fuses or faulty components, which can affect the charging efficiency. Additionally, the circuitry controlling the charging modes may malfunction, leading to incorrect charging parameters. Regular maintenance and component testing can help prevent these failures and ensure the longevity of the device.
The EXIDE UNKNOWN CHG & DIGITAL CONT BD is a battery charger and digital control board used in industrial applications. It is designed to regulate and maintain optimal charging conditions for batteries, ensuring they are charged efficiently and safely. Typical features include digital displays for monitoring charging status and adjustable settings for different battery types. Common failures in this model include malfunctioning digital displays, power supply issues, and component circuitry failures. Troubleshooting involves testing and replacing faulty components, recalibrating settings, and ensuring proper connection points.
The Exide x1060-71-1 is a high-power industrial battery charger designed for charging large rechargeable batteries commonly used in industrial applications. It features a robust construction, multiple charging modes, adjustable charge rates, and comprehensive safety features such as overcharge protection and short circuit protection. Typical failures of the Exide x1060-71-1 include internal component failures due to prolonged use, damaged charging circuits, and power supply issues. Regular maintenance and testing can help prevent these failures and ensure the charger's optimal performance.
The Exide 2000EX Power Inverter/Charger is designed to convert DC power from batteries into AC power for industrial equipment and charge the batteries simultaneously. This device features high efficiency, a wide input voltage range, and multiple protection functions like overload and short circuit protection. Typical failures in this model include blown fuses, damaged capacitors, or faulty power transistors due to overloading or poor ventilation. Regular maintenance and monitoring of input/output voltages and current levels are recommended to ensure proper functioning and prevent breakdowns.
The EXIDE 101072370 D OMNICURE is a power inverter commonly used in industrial applications to convert DC power to AC power, allowing for the operation of various electronic devices. This model features a compact design, high efficiency, and reliable performance under heavy load conditions. Typical failures include blown fuses, faulty capacitors, and damaged semiconductors due to overloading or power surges. Regular maintenance and inspections can help prevent such issues and ensure the longevity of the device.
The Exide 2000EX power inverter/charger is designed to convert DC power to AC power for industrial applications. It features a high power output capacity of 2000 watts and a built-in battery charger function. Typical failures in this unit may include blown fuses, damaged power transistors, or malfunctioning inverter circuitry due to electrical surges or component aging. Special care should be taken to ensure proper ventilation to prevent overheating issues. Regular maintenance and periodic inspections are recommended to ensure optimal performance and longevity of the unit.
The EXIDE X1060-64-8 is a power inverter designed for industrial applications. This model features a power rating of 1060 VA, 64 VDC input voltage, and 8 A output current. Typical failures of this inverter include power component failures, such as blown capacitors or transistors, as well as issues with the control circuitry or cooling system. Proper maintenance and periodic inspections can help prevent these failures and ensure the reliable operation of the inverter.
The Exide 101072372b is a battery charger commonly used in industrial settings to charge lead-acid batteries. This model features multiple charging modes, such as trickle charge, constant current, and constant voltage, to ensure safe and efficient charging. Typical failures associated with the Exide 101072372b include overheating due to a malfunctioning cooling fan, faulty circuitry leading to inconsistent charging, and component wear and tear over time. Careful inspection of the internal components and testing of the charger's output can help identify and rectify these issues.
The Exide 2000EX is a Power Inverter & Charger unit designed for industrial applications. Its primary function is to convert DC power from batteries to AC power for various electrical devices, while also providing the capability to charge the batteries. This model typically features multiple input and output options, as well as surge protection and overload protection mechanisms. Common failures observed in the Exide 2000EX unit include burnt components, blown fuses, damaged capacitors, and failure in the charging circuit. These failures are often caused by overloading, excessive heat, or poor battery connections. Regular maintenance and monitoring of input/output voltages can help prevent these failures and ensure the unit's optimal performance.
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
๐ Rush repair shipments only โ no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
๐ฆ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.