Harris is a manufacturer recognized for their high-quality precision measurement instruments catering to industrial applications. They specialize in producing advanced tools such as digital multimeters, oscilloscopes, and signal generators, trusted for their accuracy and reliability in various industrial settings. [AI]
We repair a wide range of Harris Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Harris 446995 is a precision adjustable electronic load designed for testing and evaluating power supply units, batteries, and other electrical devices. It features high accuracy and resolution for current and voltage measurements, as well as a programmable load curve for simulating real-world loads. Typical failures in the Harris 446995 include power supply issues, overheating of components, and failures in the control circuitry. Regular maintenance and calibration are recommended to ensure optimal performance.
The Harris Varistor v320pa40a is a surge protection device commonly used in industrial and residential electrical systems to protect sensitive equipment from voltage spikes and transient surges. It features a voltage rating of 320V and a peak current handling capability of 5kA. Typical failures of the Harris Varistor v320pa40a include thermal runaway, which can occur due to prolonged exposure to overvoltage conditions, leading to overheating and potentially catastrophic failure. Another common failure mode is degradation of the varistor material due to repeated surges, resulting in reduced surge absorption capacity over time. Regular testing and monitoring of the varistor's performance is recommended to ensure proper protection of the connected equipment.
The HARRIS 5268184-01 DIGIPANEL is a device utilized in industrial settings for monitoring and controlling various electronic systems. It features a compact design, digital display panel, and user-friendly interface for easy navigation. Typical failures include display malfunctions, communication errors, and power supply issues. Troubleshooting often involves diagnosing faulty components and replacing them accordingly to restore functionality.
The Harris Graphics 5347029 model is a power supply unit used in industrial printing equipment. Its main function is to convert AC power input into regulated DC output for powering various electronic components within the printing machine. This power supply unit is designed with high-quality components to ensure reliable and stable performance under demanding operating conditions. The unit is equipped with built-in protection features such as overvoltage and overcurrent protection to safeguard against electrical faults and prevent damage to connected devices. Typical failures in the Harris Graphics 5347029 model may include blown fuses, capacitor leakage or bulging, failed rectifier diodes, and burnt components due to electrical surges or overheating. Regular maintenance, inspection, and timely replacement of faulty components can help prevent these failures and ensure the continued operation of the printing equipment.
The Harris 1014545 model is a high-performance industrial electronic multimeter designed for accurate measurements of voltage, current, resistance, and other electrical parameters. It features a durable construction, large display screen for easy reading, and a range of functions such as diode testing and continuity checking. Common failures in this device often include issues with the display screen, malfunctioning probes or leads, and inaccuracies in measurements due to internal component wear. Regular maintenance and calibration are essential to ensure reliable performance.
The Harris 446994 is a widely used industrial electronic device designed for precision control and monitoring of electrical systems. It features a high-resolution display for clear visualization of data, multiple input and output channels for versatile connectivity, and robust casing for durability in harsh industrial environments. Common failures in the Harris 446994 include power supply issues, display malfunctions, and communication errors between the device and external systems. Regular maintenance and careful handling are key to ensuring optimal performance and longevity of this electronic device.
The Harris Unknown model is a multifunctional industrial electronics device designed for a wide range of applications. It features a rugged design, high performance capabilities, and advanced functionality. Typical failures of this model include power supply issues, component failures, and moisture damage. Repairing these failures often involves troubleshooting the circuitry, replacing faulty components, and calibrating the device for optimal performance.
The Harris 1014545 is a highly reliable and efficient industrial electronic device used for signal processing and control applications. It features a robust design, high-quality components, and advanced technology for enhanced performance. Common failures include power supply issues, component failures, and communication errors. Regular maintenance and timely troubleshooting can help prevent these failures and ensure the long-term functionality of the device.
The Harris 446994 is a multi-function industrial electronic device used for testing and verifying the functionality of various electronic components in industrial equipment. It features a high-resolution display, a wide range of measurement capabilities, and advanced diagnostic tools. Common failures in the Harris 446994 include display malfunctions, faulty input/output ports, and degraded internal components due to prolonged use in harsh industrial environments. Regular maintenance and calibration are essential to ensure accurate and reliable performance.
The Harris 1043624 model is a high-frequency RF amplifier commonly used in telecommunications and broadcasting applications. This amplifier is designed to amplify and boost radio frequency signals over long distances with high efficiency and reliability. Features of the Harris 1043624 model include a wide frequency range, adjustable gain and output power, temperature protection sensors, and remote monitoring capabilities. Typical failures of the Harris 1043624 model may include blown fuses, malfunctioning power supplies, damaged RF components, and overheating issues due to poor ventilation or dust accumulation. Regular maintenance and proper cooling are essential to ensure optimal performance and longevity of this amplifier.