We repair a wide range of Honeywell Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Honeywell SK-2 is a temperature controller commonly used in industrial heating and cooling systems. It features precise and stable temperature control with a digital display for easy monitoring. Typical failures include sensor malfunctions, display issues, or power supply failures, which can disrupt the temperature control process and lead to inconsistent operation. Regular maintenance and calibration are recommended to ensure reliable performance.
The Honeywell DC2001-0-0000-0000-00-011 is a versatile and reliable digital controller used in industrial applications for monitoring and control functions. Key features include multiple input types, such as thermocouple and RTD sensors, digital inputs and outputs for communication and control of external devices, and a highly intuitive user interface for easy configuration and operation. Typical failures in the Honeywell DC2001-0-0000-0000-00-011 can include power supply issues, faulty communication modules, and sensor input failures. Regular maintenance and calibration are recommended to ensure optimal performance and longevity of the device.
The HONEYWELL RA890G1229-4 Flame Safeguard is a flame safeguard control designed for industrial burner applications. Its primary purpose is to monitor and control the burner flame, ensuring safe and efficient operation of the combustion process. Key features of the HONEYWELL RA890G1229-4 include flame sensing capabilities using flame detectors, relay outputs for burner control, and self-checking diagnostics for system health monitoring. It also offers programming options for flame response time and sensitivity adjustments. Typical failures of the HONEYWELL RA890G1229-4 Flame Safeguard may include faults in the flame detection system leading to improper flame monitoring and control, relay failures causing burner shutdowns, or issues with the diagnostic functions resulting in inaccurate system status readings. Regular maintenance and functional testing are recommended to prevent downtime and ensure safe burner operation.
The HONEYWELL 10269A-1-1-03-2-00203-100-00 actuator is a device used in industrial applications to control the position of valves or dampers. It features a sturdy construction, precise positioning capabilities, and compatibility with various control systems. Typical failures in this actuator include motor burnout, mechanical wear of gears or linkages, and electrical failures such as control board malfunctions. Regular maintenance and timely replacements can help ensure optimal performance and extended service life.
The Honeywell DC5066-0-1B02-100-00-W211 is a industrial DC digital controller used for various process control applications. It features a 1/16 DIN size panel mount design with a bright LED display, programmable setpoints, and options for universal input signals. Common failures in this device include power supply issues, display malfunctions, and communication errors. Troubleshooting typically involves checking the power supply, connections, and ensuring proper input signals are being received.
The Honeywell iWS-16-0-iWS-1603 is a model of industrial controller designed for automation and monitoring applications. It features 16 digital inputs, 16 digital outputs, and 3 serial ports for communication with external devices. The controller is known for its reliability and robust construction, making it suitable for use in harsh industrial environments. Typical failures associated with the Honeywell iWS-16-0-iWS-1603 include relay failures, communication errors, and power supply issues. In some cases, the digital inputs or outputs may fail to respond, leading to loss of control or monitoring capability. Regular maintenance and thorough testing are recommended to prevent these failures and ensure the optimal performance of the controller.
The Honeywell 30750540-002 is a temperature controller designed for industrial applications. This model features precise temperature control, a user-friendly interface, and compatibility with various sensors and heating/cooling systems. Typical failures in this device include sensor malfunctions, wiring issues, and power supply failures. Regular maintenance and periodic calibration are recommended to ensure its optimal performance.
The Honeywell Riap0b is an industrial electronic device commonly used for temperature monitoring and control applications. It features high accuracy sensors, a robust construction, and a user-friendly interface for easy operation. Typical failures in the Honeywell Riap0b may include sensor malfunctions, wiring issues, or electronic component failures, which can lead to inaccurate temperature readings or complete device failure. Regular maintenance and timely repairs are recommended to ensure optimal performance and reliability.
The HONEYWELL DR45AT-1000-00-000-0-2A0000-0 is a digital circular chart recorder commonly used in industrial processes to monitor and record temperature, pressure, flow, and other process variables. It features a user-friendly interface with a large display for easy readability of data and settings. The device comes equipped with various input channels, alarm capabilities, and communication options for data transfer. Typical failures in the HONEYWELL DR45AT-1000-00-000-0-2A0000-0 may include display malfunctions, sensor input issues, power supply failures, and communication errors. These failures can often be diagnosed through troubleshooting the hardware components and recalibrating the device to ensure accurate and reliable data recording. Regular maintenance and timely repairs are essential to ensure the optimal performance of the chart recorder in industrial settings.
The Honeywell 51-000240-024 Scanner is a high-quality industrial device used for reading barcodes and QR codes in various applications. It features a durable construction, high scanning speed, and multiple interface options for seamless connectivity with other equipment. Common failures in the Honeywell 51-000240-024 Scanner include laser malfunction, damaged barcode reader head, connectivity issues, and power supply failures. Regular maintenance and timely replacement of worn-out components can help prolong the lifespan of this device.
Hello,I have a machine tool controlled by a Honeywell ISSC unit that is not working. It may have been hit by a power surge. Do you have the capability to troubleshoot and repair this unit?Thanks,Tim CutschallGMPartech Corp.β‘οΈ Reply Honeywell
Machine Error Honeywell iws-1513-hw display showing Communication Error and not responding to input commands. Production offline until issue resolved.β‘οΈ Reply Honeywell
The HONEYWELL 200220009012630003 HERCULINE 2000 is showing a flashing red LED and emitting a loud beeping sound every few minutes. The display is blank and does not respond to any button presses.β‘οΈ Reply HONEYWELL
Experiencing power issues with my HONEYWELL 51304672-100E power supply. Unit doesnt turn on and appears completely unresponsive. Looking for repair service urgently.β‘οΈ Reply Honeywell
Hi there, Im having trouble with my Honeywell TCO475-5. Something seems to have stopped working, and Im not quite sure what the issue is. Any guidance or assistance would be greatly appreciated. Thank you.β‘οΈ Reply Honeywell