We repair a wide range of Horner Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Horner HE670ADC840B is a high-performance analog input module designed for industrial applications. It features eight 16-bit analog inputs with a range of +/- 10V or +/- 20mA. The module is compatible with many PLCs, making it a versatile choice for various automation systems. Common failures include damaged input ports due to electrical surges or faulty signal conditioning components. Regular maintenance and proper grounding can help prevent these issues.
The Horner HE693ADC420B is a high-performance analog-to-digital converter module designed for use in industrial control systems. This module is capable of converting analog signals into digital data with high accuracy and resolution. It features multiple input channels, typically four or eight, allowing for the simultaneous conversion of multiple analog signals. Common failures with the Horner HE693ADC420B include issues with input signal noise, calibration drift, and component failure. These failures can lead to inaccurate or unreliable data conversion, which can impact the overall performance and reliability of the industrial control system it is integrated into. Regular calibration and maintenance are recommended to prevent and address these types of failures.
The Horner HE800DIM310A is a versatile industrial electronic device used for interfacing digital and analog input/output (I/O) signals in control systems. This model features multiple digital input and output channels, as well as analog output channels for precise control. Common failures observed in the Horner HE800DIM310A include issues with relay outputs such as welding or sticking contacts, as well as failures in the analog output circuits due to component aging or electrical damage. It is essential to perform regular maintenance checks and ensure proper grounding to prevent failures in this device.
The HORNER HE800DQM406A is a programmable logic controller (PLC) designed for industrial automation applications. It features 6 discrete inputs, 4 discrete outputs, and 6 analog inputs. The device is equipped with a high-speed processor for efficient logic handling and communication capabilities for seamless integration into larger control systems. Common failures include power supply issues, input/output module malfunctions, and communication errors due to wiring or configuration issues. Regular maintenance and thorough troubleshooting are essential for optimal performance and reliability.
The Horner HE800DQM406A is a programmable logic controller (PLC) designed for industrial automation applications. It features a high-speed processor, ample memory capacity, and a variety of communication options including Ethernet and serial ports. Common failures in the HE800DQM406A include power supply issues, communication failures, and hardware malfunctions such as faulty input/output modules or processor errors. Proper maintenance, timely firmware updates, and thorough troubleshooting practices can help extend the lifespan of this PLC.
The Horner HE693OIU357-CX controller is a versatile industrial device used for automation and process control applications. This controller features a powerful CPU, multiple communication ports for interfacing with various devices, and support for a wide range of I/O modules. Typical failures in this controller may include issues with the power supply, communication ports, or CPU malfunctions. Additionally, failures can occur due to overheating, environmental factors, or electrical surges. Proper maintenance and regular system checks can help prevent these failures and ensure reliable operation of the controller.
The Horner HE693OIU357C-12 is a high-performance input module designed for industrial control applications. This module features 32 digital input points with both isolated and non-isolated input options. It operates on a 12-24 VDC power supply and is compatible with various programmable logic controllers (PLCs). Typical failures of this module include input channel failures, power supply issues, and communication errors. Regular maintenance and troubleshooting of connections and input signals are recommended to ensure proper functioning.
The HORNER HE693OIU357-C12 is a programmable logic controller (PLC) commonly used in industrial automation systems. It features 12 digital input/output points and is designed to control various industrial processes. Typical failures of this device include power supply issues, faulty I/O modules, and communication errors. It is crucial to troubleshoot these components systematically to ensure the proper functioning of the PLC.
The Horner HE-EXL1E5JN garage door controller is designed to efficiently automate the opening and closing of garage doors. It features programmable logic control capabilities, inputs for sensors (such as for detecting obstacles), and outputs for controlling the garage door motor. Common failures in this device may include issues with the programming logic, sensor malfunctions, or motor control failures. Troubleshooting typically involves checking the input and output connections, reviewing the programming logic, and testing the sensor functionality.
The Horner HE693OIU157A is a versatile input/output module designed for industrial automation applications. It features 8 analog inputs, 4 analog outputs, and 8 digital inputs/outputs. The module is commonly used in programmable logic controllers (PLCs) to interface with sensors, actuators, and other industrial equipment. Typical failures of the Horner HE693OIU157A include damaged input/output channels due to overvoltage or electrical surges, faulty components such as resistors or capacitors, and communication errors. Regular maintenance and testing are recommended to prevent these issues and ensure the reliable operation of the module.