πŸ“ Roger Holt said:
I would like to get an estimate on fine tuning and calibrating our Komax 33.
        
πŸ“ Adan Caldera said:
Hi I have a 3 electronic board model IP1000 for Komax equipment can you help me to repair these electronic board the problem that this have are that the Crimpper dont work dont send the voltaje at the motor.Thanks for yopur help a have a nice day.
        
πŸ“ Juan G. Hernandez said:
we have a komax 33 that is not working properly. can you tell me how long will take you to do an evaulation?or how long am I looking to be with out the machine?Please let me knowJuan
        
πŸ“ Bruce Real said:
looking for operation manual for a Komax 33.
                
πŸ“ Massimiliano Brocchi said:
Dear Sirs,Id need a service manual for our machine KOMAX33 (S/N K0 4657) due to a strange error message about knife that we are not able to identify.Many thnaks in advance,Massimiliano BrocchiPlant mgr of ICAR SPAVia Nosea, 124030 Villa dAdda (BG)ITALYMob. +39 3290571734
                
πŸ“ Tom Stude said:
We have recently purchased a Komax 33. Upon power up the display comes on and we are able to change the length, size and number of pieces....etc., though the Start button LED does not come on. The emergency switch and button works. I noticed in the back a number of ports/connectors. Does this need an external source in order to run this machine?Thanks, Tom StudeCDN SystemsLeander, TX78641
                
πŸ“ James Thompson said:
I need a copy of the komax 33 manual.
                        
πŸ“ CHIKHA said:
I bought the Komax 33 i can turn it on but i dont understand how it works, i want to get the manual so i can use it.
        
πŸ“ Mary E. Perillo said:
Need a repair on an old Komax machine.
πŸ“ victor vargas said:
Hello, I need repair service for some differents electronic equippment, example, MCI 711 press board, DAC-100 Servo control, BIO KARD, SOCCAPEL, POWER SUPPLY. Do you have some prices for the repair of this items? Thanks you/
        
πŸ“ victor vargas said:
Hello, I need repair service o sell for some differents electronic equippment, example, MCI 711 press board, DAC-100 Servo control, BIO KARD, SOCCAPEL, POWER SUPPLY. Do you have some prices for the repair of this items? Thanks you/
        
πŸ“ victor vargas said:
Hello, I need repair service o sell for some differents electronic equippment, example, MCI 711 press board, DAC-100 Servo control, BIO KARD, SOCCAPEL, POWER SUPPLY. Do you have some prices for the repair of this items? Thanks you/
        
πŸ“ FERNANDO ADAME said:
HI. GOOD DAY I NEED REPAIR ONE E -CAD FROM MCI 761 I LIKE TO KNOW WHERE FOUND PIECES END IF YOU HAVE THE ELECTRONIC DIAGRAM OF THE CONTROL ..THANKS
        
πŸ“ sergio venzor said:
Hello, I have a BT711 crimp module, the ip1000 board have a system failure 4, do you know which component is damage? thanks
                
πŸ“ Foued Rihane said:
Hello Mr.I have a problem with the Komax IP 1000.The error message is : communication default.Can you tel me which componet is damage?Thanks.
πŸ“ Sergio Cavazos said:
Im needing Spindle Drives Electricam Diagrams Spindle Drive TPA/ 1 15885-603-5306B2Serian Number 2J-415C 78973-2 Rev-1Inland Drive DivisionKollmorgen CorporationIm really apprecite so much for Your help
πŸ“ Jesse Galien said:
I have a Kouwa hydraulic chiller ( model KMV-150-M16-B )attached to a Mazak FH6800 and the compressor burned up in it. I am looking for a replacement. Do you have one or know where I might find one. I need it ASAP.Thank you for your time,Jesse
        
πŸ“ Bonnie Foor said:
Hello, I am with a HVAC/R company in Southeastern Michigan and have a customer with a Kouwa chiller that needs a new compressor, I would like to help them out, can anyone point in the right direction? i called the number above but only got voicemail. It is considered an urgent situation and i would like to get an answer to my customer as soon as possible. Thank you!!!!!
        
πŸ“ Leonard Ruedlimger said:
Need condenser fan motor for an oil cooler model - KCT7-A52NPV.3 phase 200 volt 50/60 cycle.Serial number 0503-G8607Motor Model - VAS355BS-42 .2KW output.
        
πŸ“ Myles Opheim said:
Check to see if you have a Sanyo, model number C-2RN153H3A-tse or possibly a Toshiba TH207JA / TG240X2-FLwww.smallchiller.com
                
πŸ“ Richard Gillispie said:
Need to know were we can get a compressor for a model KMV-150-M15-A please respond soone, Thanks
        
πŸ“ Jesse Galien said:
Looking for a facility to repair our Kouwa hydraulic chillers ( model KMV-150-M16-B ). Are you interested?
                
πŸ“ Jim said:
Kouwa KMV-150-M16-A throws an E8 code. Ambient pressure is around 140psi at 75 degrees. Unit will run for about 3 -5 minutes and throw the code. Current to the compressor is about 3.6 amps. Is this a good value? On page 8 of the check out procedure the term thermal setting value for current is listed in the E8 alarm procedure. What is the normal thermal setting value for current draw?What are the normal operating pressures and current load for this unit when running properly? Any ideas on what needs to be replaced?
πŸ“ Nelson Oliva said:
Good morning I deal with Komatsu Parts and my question is does Industrial Electronic repair Electronic Controllers for the Komatsu Brand machines and also Detroit Diesel.
➑️ Reply Komatsu-Dresser
        
πŸ“ tim marshall said:
Hi there,Do you happen to have a controller for a komastu pc 150. The serial number is pc150-K30272 or the serial number of the controller is 21230 or part 7834-24-2001?Look forward to your reply.ThanksTim
➑️ Reply Komatsu-Dresser
        
πŸ“ GANSNER EXCAVATING & GRADING, LLC said:
HAVE A PC200LC-6L W/#7834-72-4002 MONITOR PANEL.WOULD LIKE TO HAVE CHECKED OUT & REPAIRED.THANKS,KEITH GANSNER
➑️ Reply Komatsu-Dresser
πŸ“ XAVIER ROLLAND said:
Hello,I have some problems with a KOUWA type KMV-150-M14-CCould you send me electrical sheet please ?thank you in advanceBest regardsXavier ROLLANDMaintenance ManagerFAMER INDUSTRIE
        
πŸ“ Kris Felina said:
Hello,Does anyone have a list of fault codes? Or the Troubleshooting Guide?Thank you.
        
πŸ“ steve holder said:
HiI need a replacement compressor motor for the above unit.Can they be sourced in Europe or do I need to import? either way I need cost and delivery time urgently.Steve
πŸ“ Nathan Olson said:
I have a model kmv-110-m10-a, and it is used as a spindle coolant chiller and pump for a Masak 510 mill. The problem is that I am getting three alarms. The chiller unit in giving an E-9 alarm ( Oil pressure (flow) is lowered.) Consequently, that is generating two alarms on the masak machine side. 206 Spindle Lube chiller malfunction. And also, 392 Thermal Displacement offset Error. Im sure both of the masak alarms are related to the chiller alarm. My Question is, what would cause the chiller unit to generate the E9 alarm? Plugged suction strainer? Pump going bad? Motor? The unit is only about three years old. Any advise would be greatly appreciated. P.S. The problem is intermitant. And can usually be cleared by powering off unit and machine, and powering back on. Thank you, Nathan Olson Northland Machine Inc.Grand Rapids MN218-328-6479
        
πŸ“ Gopal said:
Kindly let us know whether there is any Kouwa chiller service facility in India.
        
πŸ“ Keith Cannon said:
I have a manuel for the Kouwa model: KMV-150-M16-B-002 but not a parts list so I can order a cover for the wires above the condenser and a cover for the reset switch. Thats just a start, having the parts list would be very helpful.
        
πŸ“ Andrew Maass said:
The above Model is on a Machine where I continually get an E8 Error for Thermal Relay Overload. The Compressor will run for no more than 1 minute. Amps or Watts run high. Seems like an internal failure on Compressor. Any other thoughts before I replace Compressor? Condenser Coil is clean, great airflow. Nothing noticeable at Liquid Filter screen before Cap Tube.Also on this Unit it says Refrigerant is R407C. Any ideas on how much Refrigerant is in System in pounds?Any Tech info on this unit in regards to the Refrigeration cycle would be great.Thank you,Andrew Maass
                
πŸ“ Luis De la cruz said:
Hi , would you mind to give me a quotation for the chiller unit Model Kouwa Model KMV-150-M15.Thank you in advance.
        
πŸ“ John Swank said:
We have a new chiller that is missing a ribbon cable connecter.Is this something you could supply for us. Or would you know what we need order.Thanks John Swank (773)501-7281
        
πŸ“ Jeff Kramer said:
I am looking for a flow switch. for model #KOEJ112BOV Serial # 1510-R0490-N81. Hope you can help
        
πŸ“ JOHN D REED said:
I have a Kouwa chiller Model KMV-150-M15-B I keep getting a EJ alarm which is not in my manual. Any ideas???
        
πŸ“ CDANIEL said:
The condenser coil on my kmv-150-m34 unit is leaking , which is causing a chiller malfunction alarm. Does anyone know who to contact for a replacement condenser coil ????????
        
πŸ“ Kyle Weeks said:
Have an Eu alarm on a brand new Kouwa chiller unit on a Mazak ST550. can not clear. Any suggestions?
πŸ“ STEVE GARNHART said:
I have a KOUWA liquid tuner MODEL KMV-150-M14 using R407C refrig. I have installed a new compressor in this unit and need to know the amount of refrigerant to install in the unit. Iwould also like the running pressures thank you
πŸ“ Holohan Heating and Sheetmetal said:
I have a customer that is using a Kouwa Mod# KMU-150-M-16-B S/N 181776 oil cooler. Can you tell me what pressures to expect and how much 407C is supposed to be in the unit? We just replaced a stuck compressor and my suction pressure is at 0Psi. Performed system flush, installed new strainer and cap tube. Mazak hasnt a clue.ThanksJohn ArrinigtonHolohan Inc.Kankakee,Illinois
        
πŸ“ Gurmit Pine said:
Please let me know where i can get New or Rebuilt Liquid Tuner # GKN-75-HFVC
        
πŸ“ mandervelt said:
I have a customer that is using a kouwa KMV-110-M10-A oil cooler can you sendt my a parts list.Mandervelt J.M.Gemacool Genk,Belgie
                
πŸ“ Patxi Mugica said:
I have a customer that is using a kouwa KMV-110-M10-A oil cooler can you sendt my a parts list.KMV-110P-M10-C01
        
πŸ“ aris budianto said:
Type : KCT 7 -A52n-ASerial : 0807-H0256
        
πŸ“ ADRIAN PENA ALANIS said:
Hello, We have a bad compressor SANYO part: C-2RN153H3A code: 80805183 This it installed on KOUWA LIQUID TUNER model: KMV-150-M16-B Mfg. No. 0601-M7189 Could you send us please price and delivery time. We are in Nuevo Leon, Mexico. Please, send the answer as soon as posibble. Thanks.
                
πŸ“ Dhani Persaud said:
Looking for pricing for a compressor # C-2NR153H3a (808-051-83) and a fan motor # VAS405BS-42. Both from a Kouwa chiller unit # KMV-150-M14-A
        
πŸ“ Stephan Holzinger said:
spare parts price and delivery time for a compressor for KMV 110 M21-A
πŸ“ Gary Eckman said:
Do you sell compressor pumps for a KMV-150-M14? If not can you tell me where I can locate one. Thank you, Gary
πŸ“ Heru Sukoco said:
Hi Mr/Mrs,Please advise your availability and price of compressor and main board for below machine type:KOUWA liquid tuner model KCT7-A52NThose parts to be delivered to Jakarta Indonesia.Best Regards,Heru
        
πŸ“ Alain GOLLING said:
Hello,i would like to have price and deliveryconditions for a compressor KOUWA type KMV-150-M14-C-002 on R407 C gas and 3 x 200 V 50/60Hz.Can you inform me as soon as possible please ?I am a refrigeration company in Belgium (www.golling.be)Best Regards,Alain GOLLING
        
πŸ“ Alain GOLLING said:
Hello,i would like to have price and deliveryconditions for a compressor KOUWA type KMV-150-M14-C-002 on R407 C gas and 3 x 200 V 50/60Hz.Can you inform me as soon as possible please ?I am a refrigeration company in Belgium (www.golling.be)Best Regards,Alain GOLLING
                
πŸ“ Menissier said:
bonjour je recherche un compresseur R407C KOUWA LIQUD TUNER KMV-150-M14TARIF + FRAIS DE PORT ET DELAISSALUTAITONS
        
πŸ“ steve Holder said:
HiI need a compressor motor for a KMV-150-M14-C, we require this part urgently so details of agents in the UK or Europe would be helpful.is there a specification available for this compressor so we can source our own unit?
        
πŸ“ ZEKE said:
WORKING ON CHILLER UNIT ON A MAZAK AND IT KEEPS SHUTING DOWN WITH AN E6 ERROR CODE . IVE CLEANED THE COIL AIR FILTERS ALL THE Y SUCTION STRAINERS . BUT WHEN I POWER UP MACHINE FAN COMES FOR TWO SECONDS AND QUITS. NEED SOME HELP PLEASE
πŸ“ Mark Schwiegershausen said:
Can the temp diff. be set any greater on a KMU-150-M16-B liquid tuner? the system currently has about 1 deg C between on/off cycle. Orignial compressor locked up. Charge was correct. We believe the excessive start/stop of the unit caused lock-up
πŸ“ Luis Raul Godinez said:
repair cost ip1000and i need used qty.3
πŸ“ Dian Smith said:
Hello,I am reaching out on behalf of a client who is experiencing issues with their Komax 33 wire machine. The part number involved is . The client has described a problem with the machine, but I do not have all the details at the moment. Could you please provide me with some guidance on how we can address this issue?Thank you for your assistance.Best regards,
πŸ“ Joe Colombo said:
I have a Showa temperature controller Model#sho-650-104-lfvc-dc in the instruction manual it says to contact you for service.Is ths correct? and if it is do you have parts and tech support. our unit is running but we are going to need filters ect. down the road.thank you for your time,Joe colombo
πŸ“ Mr. Peerasij chadathorn said:
I need a troubleshooting manual for KOUWA LIQUID TUNER model: KCT7-A52N (english langauge). Now machine alarm code show E2. Thank you Peerasij
        
πŸ“ suresh mahajan said:
Pls technical support
        
πŸ“ dinh cong nguyen said:
I need a troubleshooting manual for KOUWA LIQUID TUNER model :GK-150T-FZC-BE (english langauge).Now machine alarm code show E6 .Thank you
                
πŸ“ Ying said:
Dear all :We are looking control Board, P/N : NAYUTA NB-584 01855B = 1 unit. Pls advice your price + freight cost + lead time to us.Best regards,Ms. Ying
        
πŸ“ Joel ARCHULETA said:
I need an English manual for model KMV-150-M15-H serial 1906- M2328. I also need some sort of guidance with dip switch settings on the board.
πŸ“ BATSCH said:
Seeking repair for a Korteck KT-LS15XH LCD Monitor displaying a flickering screen with distorted colors. Need assistance urgently. Thank you.
πŸ“ David Goodrich said:
I am getting an EA fault code on tuner display as soon as the unit is powered up. The EDM that it is attached to comes up with a false U794 high fluid temp alarm. I have checked all the wiring and fuses as well as the phasing of the motors.
πŸ“ edmundo navarro said:
we have a Mazak VCN 510 C serial 162546 march 2003 with a schiller KMV-75-M02 the board NAYUTA NB-584 is out of orderWe do not know if the display is ok or notpls your comments asap we are in a hurry with that machine cordially
πŸ“ Rashpal Singh said:
Hello there,We have Mazak 410 VMC with Serial no. 175268. There is Kouwa Liquid Tuner installed in it for spindle lubrication with Model no. KMV-75-M02-B with Mfg. No. 0607-M9038. It shows EE alarm on display and we are not capable to remove it. Kindly provide a suitable person or mail-id or if you can provide support through mail-id. Our machine is idle from last 20 days. Thanks & RegardsRashpal SinghIn-charge CNC SectionFor Ambika Overseas,Model House Road, Basti Shiekh,Jalandhar - Punjab (INDIA)
πŸ“ Chris Haigler said:
Our tuner got a E9 error and then the controller went out. Pulled the controller cover and found NB0793 is smoked. We are trying to locate another circuit board to replace it with or maybe even have this one repaired; whatever is the quickest. Thanks, Chris Haigler
        
πŸ“ Alan Trimue said:
Good morning our unit a KMV-150-M16-C. tHREW AN E8 fault. Per Mazak tech he said it was a bad compressor. We are trying to locate a compressor for this unit. We have a very hot job to run on this machine and need it repaired asap. Any help would be greatly appreciated. If you need additional info call Alan E. Trimue at 989-274-5675. Thank you.
πŸ“ Ramesh kumar said:
Kouwa Liquid tuner Fan motor D-PT-Z 222-S required & send details in India sale& service contact no , Email address, This liquid tuner using for Mazak m/c ,
πŸ“ John Lynch said:
Getting an E7 alarm on the unit. What is the normal cause of this?
πŸ“ Darrel said:
I need a compressor for a kouwa kmv-150-m15-b but the BTU of the unit is not listed in the maunual. Its a 220v 3ph system.Do you sell the compressors? If so how much are they and what is the BTU rating?Thanks!!
πŸ“ jerry fritts said:
hello i have a kouwa chiller on my mazak its flashing EJ on unit wanted to see what this meant thanks
πŸ“ Greg Patterson said:
Urgent Repair Needed for Korteck KT-LS15XH LCD MonitorGreetings,Our Korteck KT-LS15XH LCD monitor is displaying a blank screen with no power indication. No error codes or alarms are shown. We urgently require your expertise to diagnose and resolve this issue.Looking forward to your
πŸ“ John Demers said:
Mazak 6800 HMC uses Model KMV-150-M14-C. Had a 30 amp trip shut down machine. Traced to low oil in the in the Hysol (Left side oil fill port). Still tripped. The CM motor starter 4th from left was dirty with carbon. We changed it out. Still trips. We ohmed out the motor. Seemed good. Thinking what the motor is spinning had frozen up but the e stop wont go away and the chiller never starts. I get the 4 dashes at boot up and I can push the parameter button to see A200. Nothing else shows on the display, no alarms.
πŸ“ Tom Lutz said:
I Have Model # KMV-75-M02-A W/ No Manual Alarm E1 on Unit.
πŸ“ MY SELF SIRAJ said:
Board failure on Konecrane D2V018NF1NO6 18kW Dynac Vector 2 Inverter. Need to replace it ASAP to minimize downtime.
πŸ“ Bill Raudenbush said:
The Koyo Electronics Industries Co D3-350 DIRECT LOGIC 405RS is experiencing severe connection issues, causing major disruptions to the production line. Urgent repair is required to restore functionality and minimize production downtime. Please prioritize this issue and provide immediate assistance.
➑️ Reply Koyo Electronics Industries Co
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Contact Us

πŸš‘Shop LocationπŸ› οΈ

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
πŸš‘ Rush repair shipments only β€” no walk-ins.

πŸ“žPhone

1-336-969-0110

πŸ“¦Mailing AddressπŸš›

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
πŸ“¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.