We repair a wide range of Keithley Equipment.
Ask questions, or call 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Keithley 173A is a benchtop digital multimeter commonly used in industrial electronics repair. Its primary purpose is to measure various electrical parameters such as voltage, current, resistance, and capacitance with high precision. The device features a large, easy-to-read display, multiple measurement ranges, and functions for data logging and trend analysis. Typical failures in the Keithley 173A include display malfunction, inaccurate readings, and faulty input jacks due to wear and tear. Regular calibration and maintenance are recommended to ensure accurate and reliable measurements.
The Keithley 35050A readout unit is designed for accurate display and measurement of various parameters in industrial settings. It features a high-resolution LED display for easy reading and provides precise measurements of voltage, current, resistance, and temperature. Common failures in the Keithley 35050A unit include display malfunctions, faulty input ports, and power supply issues. Regular calibration and maintenance are recommended to ensure optimal performance and accuracy.
The Keithley 173A is a high-precision AC millivolt meter designed for measuring small signals in research and industrial applications. Its features include a wide measurement range, high accuracy, and low noise. Typical failures in the Keithley 173A may include issues with the input connections, calibration drift, or problems with the display or controls. Regular calibration and maintenance are recommended to ensure accurate and reliable measurements.
The Keithley pio-96 is a high-performance digital I/O module designed for use in various industrial applications. It features 96 channels of digital input and output with high voltage and current capabilities, making it suitable for interfacing with various sensors, switches, and actuators. Typical failures of the Keithley pio-96 module include issues with the digital input/output channels, such as short circuits, open circuits, or voltage spikes. Additionally, failures in the communication interface or power supply can also occur. Regular maintenance and troubleshooting are recommended to ensure optimal performance and reliability of the device.
Dear SirWe have in our possession the following I/O cards installed on a Workhorse Alarm Monitoring system on board our subject vessel.Kindly advise if you have the means to troubleshoot and repair these old cards.two pcs WH-D11-16 PC7472,14144 , this one does not complete the scan cycle (the orange light is not lit)one pc WH-AEX-16 PC7392 14145two pc WH-PCDB-ISO PC7362 14156 REV 2Your prompt reply will be highly appreciated.With Kind regardsK. Karathanosโก๏ธ Reply Keithley