Kouwa specializes in designing and producing high-performance hydraulic cylinders and pneumatic systems for a variety of industrial applications. Their precision engineering and focus on quality make them a trusted supplier in the industry. [AI]
We repair a wide range of Kouwa Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Kouwa NB0793 controller board is designed for industrial applications to manage and control various systems in a production environment. It features a high processing power and compatibility with a wide range of input and output devices. Typical failures include malfunctioning communication ports, power supply issues, and damage to the central processing unit. Regular maintenance and proper handling are essential to ensure the board's longevity and optimal performance.
The Kouwa KMV-75-M02-B is an industrial chiller designed to regulate the temperature of various industrial processes. It features a cooling capacity of 75 kW and is equipped with a digital temperature controller for precise temperature monitoring and adjustment. Common failures in chillers like the Kouwa KMV-75-M02-B include refrigerant leaks, compressor motor malfunctions, and issues with electronic control components. Regular maintenance and timely repairs are essential to ensure optimal performance and longevity of the chiller.
The Kouwa NB0793 circuit board is utilized in industrial applications for controlling various electronic processes. This circuit board features multiple input and output channels to interface with sensors, actuators, and other equipment. Common failures in this board include damaged traces, blown components, and faulty solder joints. Repairing such issues involves troubleshooting the circuits, replacing defective components, and ensuring proper reflow of solder joints.
The Kouwa SKD chiller is designed for industrial cooling applications. It features a robust refrigeration system with a high-capacity compressor, condenser, and evaporator for efficient heat transfer. The unit is equipped with a user-friendly control panel for monitoring and adjusting temperature settings. Common failures in the Kouwa SKD chiller include compressor motor issues, refrigerant leaks, and sensor malfunctions. Regular maintenance and timely repairs are essential to ensure optimal performance and longevity of the chiller unit.
The Kouwa TCM3A circuit board is used in industrial equipment for signal processing and control functions. It features a compact design with high reliability and precision. Common failures include burnout of components due to overvoltage, solder joint failures, and contamination leading to intermittent connections. Regular inspection and maintenance are recommended to ensure optimal performance.
The Chiller Control Board model Kouwa KMV-75-M02-B is designed to regulate and monitor the operation of industrial chillers. It includes features such as temperature sensors, control relays, communication interfaces, and a display panel. Typical failures of this unit include relay malfunction, sensor calibration issues, and power supply failure. Regular maintenance and periodic calibration are recommended to ensure optimal performance.
The Kouwa KMV-150-M16-C chiller is a crucial component in industrial applications, designed to control and monitor the temperature of various processes by using a refrigeration cycle. It features a robust compressor, condenser, evaporator, and expansion valve to maintain a consistent and precise temperature within the specified range. Common failures include compressor issues such as overheating or mechanical failures, refrigerant leaks, and sensor malfunctions leading to inaccurate temperature readings. Regular maintenance and timely repairs are essential to ensure optimal performance and longevity of the chiller unit.
The Kouwa KMV-150-M16-C is a circuit board primarily used in industrial machinery for control and monitoring functions. It features a compact design with 16 input/output channels and is highly reliable in harsh industrial environments. Typical failures may include burnt components, loose connections, or malfunctioning chips. Regular inspection and maintenance are recommended to ensure optimal performance and longevity of the circuit board.
The Chiller Unit model Kouwa SB0001 is an industrial electronic device used for cooling purposes in various applications such as manufacturing plants, data centers, and commercial buildings. It features a high-capacity cooling system that utilizes refrigeration technology to maintain optimal temperatures within a controlled environment. Typical failures in Chiller Units include refrigerant leaks, compressor failures, faulty control systems, and sensor malfunctions. Regular maintenance and prompt repairs are essential to ensure the efficient operation of the Chiller Unit.
The Chiller Unit Board model Kouwa KMV-75-MOZ-B is a vital component in industrial chiller systems responsible for regulating and controlling the cooling process. It features advanced microprocessor technology for precise temperature control, fault monitoring, and system optimization. Common failures in this unit may include issues with the power supply, faulty connections, and damage to the microprocessor or other critical components. Regular maintenance and prompt troubleshooting are essential to ensure optimal performance and longevity of the chiller unit board.
I have a Kouwa hydraulic chiller ( model KMV-150-M16-B )attached to a Mazak FH6800 and the compressor burned up in it. I am looking for a replacement. Do you have one or know where I might find one. I need it ASAP.Thank you for your time,Jesse— Purchase or Repair:➡️ Reply Kouwa
Hello,I have some problems with a KOUWA type KMV-150-M14-CCould you send me electrical sheet please ?thank you in advanceBest regardsXavier ROLLANDMaintenance ManagerFAMER INDUSTRIE— Purchase or Repair:➡️ Reply Kouwa
I have a model kmv-110-m10-a, and it is used as a spindle coolant chiller and pump for a Masak 510 mill. The problem is that I am getting three alarms. The chiller unit in giving an E-9 alarm ( Oil pressure (flow) is lowered.) Consequently, that is generating two alarms on the masak machine side. 206 Spindle Lube chiller malfunction. And also, 392 Thermal Displacement offset Error. Im sure both of the masak alarms are related to the chiller alarm. My Question is, what would cause the chiller unit to generate the E9 alarm? Plugged suction strainer? Pump going bad? Motor? The unit is only about three years old. Any advise would be greatly appreciated. P.S. The problem is intermitant. And can usually be cleared by powering off unit and machine, and powering back on. Thank you, Nathan Olson Northland Machine Inc.Grand Rapids MN218-328-6479— Purchase or Repair:➡️ Reply Kouwa
I have a KOUWA liquid tuner MODEL KMV-150-M14 using R407C refrig. I have installed a new compressor in this unit and need to know the amount of refrigerant to install in the unit. Iwould also like the running pressures thank you— Purchase or Repair:➡️ Reply Kouwa
I have a customer that is using a Kouwa Mod# KMU-150-M-16-B S/N 181776 oil cooler. Can you tell me what pressures to expect and how much 407C is supposed to be in the unit? We just replaced a stuck compressor and my suction pressure is at 0Psi. Performed system flush, installed new strainer and cap tube. Mazak hasnt a clue.ThanksJohn ArrinigtonHolohan Inc.Kankakee,Illinois— Purchase or Repair:➡️ Reply Kouwa
Do you sell compressor pumps for a KMV-150-M14? If not can you tell me where I can locate one. Thank you, Gary— Purchase or Repair:➡️ Reply Kouwa
Hi Mr/Mrs,Please advise your availability and price of compressor and main board for below machine type:KOUWA liquid tuner model KCT7-A52NThose parts to be delivered to Jakarta Indonesia.Best Regards,Heru— Purchase or Repair:➡️ Reply Kouwa
Can the temp diff. be set any greater on a KMU-150-M16-B liquid tuner? the system currently has about 1 deg C between on/off cycle. Orignial compressor locked up. Charge was correct. We believe the excessive start/stop of the unit caused lock-up— Purchase or Repair:➡️ Reply Kouwa
I have a Showa temperature controller Model#sho-650-104-lfvc-dc in the instruction manual it says to contact you for service.Is ths correct? and if it is do you have parts and tech support. our unit is running but we are going to need filters ect. down the road.thank you for your time,Joe colombo— Purchase or Repair:➡️ Reply Kouwa
I need a troubleshooting manual for KOUWA LIQUID TUNER model: KCT7-A52N (english langauge). Now machine alarm code show E2. Thank you Peerasij— Purchase or Repair:➡️ Reply Kouwa
I am getting an EA fault code on tuner display as soon as the unit is powered up. The EDM that it is attached to comes up with a false U794 high fluid temp alarm. I have checked all the wiring and fuses as well as the phasing of the motors.— Purchase or Repair:➡️ Reply Kouwa
we have a Mazak VCN 510 C serial 162546 march 2003 with a schiller KMV-75-M02 the board NAYUTA NB-584 is out of orderWe do not know if the display is ok or notpls your comments asap we are in a hurry with that machine cordially— Purchase or Repair:➡️ Reply Kouwa
Hello there,We have Mazak 410 VMC with Serial no. 175268. There is Kouwa Liquid Tuner installed in it for spindle lubrication with Model no. KMV-75-M02-B with Mfg. No. 0607-M9038. It shows EE alarm on display and we are not capable to remove it. Kindly provide a suitable person or mail-id or if you can provide support through mail-id. Our machine is idle from last 20 days. Thanks & RegardsRashpal SinghIn-charge CNC SectionFor Ambika Overseas,Model House Road, Basti Shiekh,Jalandhar - Punjab (INDIA)— Purchase or Repair:➡️ Reply Kouwa
Our tuner got a E9 error and then the controller went out. Pulled the controller cover and found NB0793 is smoked. We are trying to locate another circuit board to replace it with or maybe even have this one repaired; whatever is the quickest. Thanks, Chris Haigler— Purchase or Repair:➡️ Reply Kouwa
Kouwa Liquid tuner Fan motor D-PT-Z 222-S required & send details in India sale& service contact no , Email address, This liquid tuner using for Mazak m/c ,— Purchase or Repair:➡️ Reply Kouwa
Getting an E7 alarm on the unit. What is the normal cause of this?— Purchase or Repair:➡️ Reply Kouwa
I need a compressor for a kouwa kmv-150-m15-b but the BTU of the unit is not listed in the maunual. Its a 220v 3ph system.Do you sell the compressors? If so how much are they and what is the BTU rating?Thanks!!— Purchase or Repair:➡️ Reply Kouwa
hello i have a kouwa chiller on my mazak its flashing EJ on unit wanted to see what this meant thanks— Purchase or Repair:➡️ Reply Kouwa
Mazak 6800 HMC uses Model KMV-150-M14-C. Had a 30 amp trip shut down machine. Traced to low oil in the in the Hysol (Left side oil fill port). Still tripped. The CM motor starter 4th from left was dirty with carbon. We changed it out. Still trips. We ohmed out the motor. Seemed good. Thinking what the motor is spinning had frozen up but the e stop wont go away and the chiller never starts. I get the 4 dashes at boot up and I can push the parameter button to see A200. Nothing else shows on the display, no alarms.— Purchase or Repair:➡️ Reply Kouwa
I Have Model # KMV-75-M02-A W/ No Manual Alarm E1 on Unit.— Purchase or Repair:➡️ Reply Kouwa
We are currently encountering an error code E9 on our unit, which indicates low oil pressure (flow). I am unsure why this is happening, as the three circulation pumps and the compressor are not activating. Additionally, the CNC lathe which we are using the unit on, does not trigger an alarm indicating that the unit is not cooling the oil. Can you assist us in understanding the problem and finding a solution? Thank you in advance.— Purchase or Repair:➡️ Reply Kouwa
Hi there, Can the Kouwa KMV-75-MOZ-B chiller unit board be repaired or purchased as a replacement? Im trying to check this off my to-do list. Thank you.— Purchase or Repair:➡️ Reply Kouwa
The Kouwa KMV-75-M02-B unit is not functioning properly according to the maintenance team. Please inspect and troubleshoot as needed.— Purchase or Repair:➡️ Reply Kouwa
My Kouwa KMV-75-M02-B liquid tuner isnt functioning correctly and needs repair as soon as possible.— Purchase or Repair:➡️ Reply Kouwa