Welcome to Linx

Linx specializes in providing innovative coding and marking solutions for industrial applications. Their product line includes continuous inkjet printers, laser coders, and thermal transfer printers designed to meet the diverse marking needs of manufacturers worldwide. [AI]

We repair a wide range of Linx Equipment.

Ask questions, or 1-336-969-0110 for faster service.

Use the search bar above to find specific manufacturers.


Why to send us your work?

To receive more information about your Linx industrial electronics unit, please contact us at 1-336-969-0110. We offer testing, refurbishment, and extended warranty support for Linx equipment. Our team of experts is here to assist you with any questions or concerns you may have.

๐Ÿ› ๏ธ Common AI Repair Summaries ๐Ÿญ

๐Ÿ”ง Linx VA-2/Q DATA TERMINAL(Unknown)

The LINX VA-2/Q Data Terminal is a device used for data communication in industrial environments. It features a rugged design suitable for harsh conditions, digital and analog input/output options, and a user-friendly interface for easy operation. Typical failures include damage to communication ports, power supply issues, or software malfunctions. Regular maintenance and proper handling can help extend the device's lifespan.

  • Part: DATA TERMINAL
  • Est. Repair Price: $1,796.00 (est.)
๐Ÿ”ง Linx 0633-583 POWER BOARD(Unknown)

The LINX 0633-583 power board is designed to regulate and distribute power within industrial electronic systems. It features multiple input and output channels, as well as various protection mechanisms to safeguard against power surges and overloads. Typical failures of the LINX 0633-583 power board include blown fuses, faulty capacitors, and damage to voltage regulators. These issues can result in system downtime and disruption to operations, necessitating prompt repair or replacement of the power board.

  • Part: POWER BOARD
  • Est. Repair Price: $1,170.00 (est.)
๐Ÿ”ง Linx 0633-498 CHART RECORDER(Unknown)

The LINX 0633-498 chart recorder is a device used in industrial settings to monitor and record various process variables over time. It typically features a built-in printer for real-time data logging, a variety of input channels for connecting to different sensors, and a digital display for easy data visualization. Common failures in the LINX 0633-498 chart recorder include malfunctioning printer mechanisms, issues with input signal acquisition or processing, and display malfunctions. These failures can often be attributed to wear and tear, component aging, or electrical surges. Troubleshooting and repairing these issues usually involve testing and replacing faulty components, recalibrating the device, and ensuring proper electrical connections.

  • Part: CHART RECORDER
  • Est. Repair Price: $1,170.00 (est.)
๐Ÿ”ง Linx 0636-129 DRIVER UNIT(Unknown)

The LINX 0636-129 Driver Unit is a high-performance electronic device used in industrial automation systems. Its primary purpose is to control the operation of various components within a machine or system by providing precise signals to motors, actuators, or other devices. This driver unit is known for its reliability and efficiency in translating control signals into movement or action. It features multiple input and output channels, allowing for versatile connectivity with different types of sensors and actuators. Additionally, it is equipped with advanced protective mechanisms to ensure the safety and longevity of connected devices. Typical failures in the LINX 0636-129 Driver Unit may include issues with power supply components, defective output channels, or malfunctioning communication interfaces. Regular maintenance and prompt troubleshooting are essential to prevent costly downtime and ensure optimal performance of this critical electronic device.

  • Part: DRIVER UNIT
  • Est. Repair Price: $1,230.00 (est.)
๐Ÿ”ง Linx 6635-993 FET DRIVER(Unknown)

The LINX 6635-993 FET Driver is designed to efficiently control the switching of power semiconductor devices such as MOSFETs or IGBTs. It features high-speed, high-current capability to drive these devices with precision and reliability. This FET driver is commonly used in motor control applications, power supplies, and inverters. Typical failures of the LINX 6635-993 FET Driver include shorted or open driver outputs, damaged gate drive circuits, faulty optocouplers, and power supply issues. These failures can lead to improper switching of power devices, loss of control, and ultimately system malfunction. Proper testing and troubleshooting techniques are essential to diagnose and repair these issues effectively.

  • Part: FET DRIVER
  • Est. Repair Price: $1,400.00 (est.)
๐Ÿ”ง Linx UNKNOWN 8KV POWER SUPPLY(Unknown)

The LINX Unknown 8kV Power Supply is a high-voltage power supply designed for industrial applications. It provides a stable output voltage of 8kV for various electronic systems. This power supply is equipped with overcurrent protection, overvoltage protection, and short-circuit protection features to ensure the safety of the connected devices. Typical failures of this power supply include component degradation, capacitors failure, and voltage regulation issues. Maintenance of this power supply involves regular inspection of components and voltage calibration to ensure proper functioning.

  • Part: 8KV POWER SUPPLY
  • Est. Repair Price: $596.00 (est.)
๐Ÿ”ง Linx 6635-441 IPM(Unknown)

The LINX 6635-441 IPM is a high-power integrated power module typically used in industrial applications. It is designed to provide efficient conversion of electrical power, with features such as built-in protection circuits, integrated gate drivers, and thermal management systems. Common failures in the LINX 6635-441 IPM include short-circuiting due to overvoltage or overcurrent conditions, thermal stress leading to device overheating, and malfunctioning gate drivers causing issues with power switching. Regular maintenance and monitoring of operating conditions are recommended to prevent these failures.

  • Part: IPM
  • Est. Repair Price: $250.00 (est.)
๐Ÿ”ง Linx cb13316/2 (PCB Display)

The Linx CB13316/2 is a printed circuit board (PCB) display commonly used in industrial electronics for visual data representation. This display unit features a compact design with a high-resolution screen for clear and detailed information display. Typical failures of this PCB display include issues with the backlight, pixel malfunctions, connector damage, or problems with the control circuitry. Repairing this unit often involves troubleshooting these components and replacing any faulty parts to restore its functionality.

  • Part:
  • Est. Repair Price: $1,900.00 (est.)
๐Ÿ”ง Linx III-2/Q (Unknown)

The LINX III-2/Q is a high-performance industrial electronics device that is commonly used for data acquisition and control applications. It features a robust design, multiple input/output channels, high-speed data processing capabilities, and a user-friendly interface for easy configuration and monitoring. Common failures in the LINX III-2/Q may include overheating due to poor ventilation, power supply issues, or component failures on the circuit board. Regular maintenance and proper installation can prevent these failures and ensure the device's reliable performance.

  • Part:
  • Est. Repair Price: $1,230.00 (est.)
๐Ÿ”ง Linx 0638-358-008 LASER(Unknown)

The LINX 0638-358-008 LASER is a compact and high-performance laser module commonly used in industrial applications for marking and engraving on various materials. It features a stable and precise laser beam output with a long lifespan. Typical failures include diode degradation, optics contamination, and power supply issues, which may result in decreased laser performance or complete failure. Regular maintenance and calibration are recommended to ensure optimal functionality.

  • Part: LASER
  • Est. Repair Price: $1,170.00 (est.)

Comments for Linx

0 comments found.
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Contact Us

๐Ÿš‘Shop Location๐Ÿ› ๏ธ

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
๐Ÿš‘ Rush repair shipments only โ€” no walk-ins.

๐Ÿ“žPhone

1-336-969-0110

๐Ÿ“ฆMailing Address๐Ÿš›

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
๐Ÿ“ฆ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.