I have a Melco Emt 10-4T and apparently had a power surge. It seems to have burned up some boards, at least some components. I replaced the power supply because I could see one component fried. Still cant get the machine to work. It will display e-stop engaged. I have disconnected the emergency stop buttons but it still doesnt work.β Purchase or Repair:β‘οΈ Reply Melco
Hi, our Melco 10512-02 power supply unit is displaying error code E02 and is not powering on. Please advise on troubleshooting steps. β Purchase or Repair:β‘οΈ Reply Melco
The Melco 10512-02 power supply is showing error code E112. Equipment is currently offline and in need of urgent repair. Thank you. β Purchase or Repair:β‘οΈ Reply Melco
I have a Melco 10512-02 power supply unit that needs repair. Its currently not supplying power to the machine and I need it fixed urgently. β Purchase or Repair:β‘οΈ Reply Melco
weve got an issue with the Melco 10512-02 power supply - looks like one of the drives or boards just failed. Need to address this ASAP. β Purchase or Repair:β‘οΈ Reply Melco
We experienced downtime due to a malfunction in the Melco 10512-02 power supply unit. The issue occurred at 1030 PM and we are urgently seeking a resolution before the next shift begins. β Purchase or Repair:β‘οΈ Reply Melco
The Melco 10512-02 power supply unit is not working. β Purchase or Repair:β‘οΈ Reply Melco
The Melco 10512-02 power supply unit you provided is not working. β Purchase or Repair:β‘οΈ Reply Melco
Do you have a Melco 10512-02 power supply available for sale or repair? Production is currently offline and we need to get it up and running as soon as possible. Thank you. β Purchase or Repair:β‘οΈ Reply Melco
CAN THEY BE REPAIRED OR ANY AVIALABLE. THANKSβ Purchase or Repair:β‘οΈ Reply Melco
We have a Melco EMT 10/4T machine with a start-up boot problem. I believe there may be a electronics hardware problem (memory error?). Error is BOOT DISK ERROR_. After replacing the floppy disk drive and new boot floppy disk a closer examination indicates a problem in the self test routine (I think). The system used to go through the self tests and then looks for the floppy but now stops after the RSA Memory Test PASSED, and immediately displays B4 and stays there until enter is pushed again.Do you have any idea where to start troubleshooting? I have an electronics degree so you can talk as technical as you wish. We were hoping to diagnose the problem and send you only the defective part for repair. (my guess is dynamic ram error bank 4 on CPU board but just a guess). See the following boot display sequences. Any Help would be greatly appreciated!System stack PASSEDRSA Memory PASSED (then jumps immediately to B4 and stays until Enter is pushed)Bunch of corrupt characters now displayed (stays on that screen until Enter is pushed)Lan Card Locate PASSEDLAN EEPROM LOAD PASSEDSelf-test PASSEDEBIOS V1.04 928KINSERT BOOT DISK_BOOT DISK ERRORmachine infoMelco EMT 10/4T Model 01050002Serial # 790799Mfg date 01/2000β Purchase or Repair:β‘οΈ Reply Melco