The Mirtone 79021/50 is a fire alarm panel designed to monitor and control fire detection devices within a building. It features LED indicators for alerting users to alarm or fault conditions, as well as a user-friendly interface for system configuration and testing. Common failures in fire alarm panels include power supply issues, faulty circuitry, and communication errors with connected devices. Regular maintenance and testing are essential to ensure the proper functioning of the unit.
The Mirtone 7516 Power Supply is a crucial component in industrial electronic systems, providing a stable voltage output to various devices within the system. It features overcurrent and overvoltage protection, ensuring the connected devices are shielded from potential damage. Typical failures in this power supply unit include component degradation, overheating, and power fluctuations, resulting in erratic voltage outputs or complete power failure. Regular maintenance and monitoring are recommended to prevent these issues and ensure system reliability.
The Mirtone Assy-50060300 circuit board is a critical component in fire alarm systems, responsible for processing signals from various sensors and initiating appropriate alarm responses. It features multiple integrated circuits, resistors, capacitors, and connectors for seamless communication with other system components. Typical failures include burnt traces, damaged components, and faulty connectors, often resulting from power surges or improper handling during installation or maintenance. Regular inspection and timely repair or replacement of damaged parts are essential to ensure the system's continued reliability and functionality.
The Mirtone 79045 board is a crucial component used in industrial fire alarm systems. Its primary function is to control and monitor various aspects of the fire alarm system, such as sensors, horns, and strobes. The board features multiple input and output connections for interfacing with different devices within the system. Some common failures associated with the Mirtone 79045 board include power supply issues, communication failures, and component degradation due to environmental factors. It is important to regularly inspect and maintain this board to ensure the proper functioning of the fire alarm system.
Control Panel Mirtone 7516 is a device used in industrial settings to regulate and monitor various electrical systems. It features a compact design, multiple input and output ports, a digital display for system status monitoring, and control buttons for manual operation. Typical failures include power supply issues, connector failures, and display malfunctions. Regular maintenance and proper installation can help prolong the lifespan of the control panel.
The Mirtone 78001500 Alarm Board is an essential component of alarm systems in industrial settings. Its primary function is to receive signals from various sensors and trigger audible and visual alarms in case of an emergency or abnormal conditions. The board features multiple input channels for connecting sensors and outputs for alarms or notifications. Common failures in alarm boards like the Mirtone 78001500 include power supply issues, faulty relays, or damaged input/output connections due to environmental factors such as moisture or dust. Regular maintenance and proper installation can help prevent these failures and ensure the reliable operation of the alarm system.
The Fire Alarm Panel LED Board is a crucial component in a fire alarm system that provides visual indications of various statuses and alarms. The Mirtone 25280225-2 LED Board features a series of light-emitting diodes (LEDs) that illuminate to signal normal operation, alarms, faults, or other system conditions. Typical failures of this board may include burnt out LEDs, loose connections, or issues with the circuitry that control the LED indicators. Proper maintenance and periodic testing of this component are essential to ensure the reliability of the fire alarm system.
The Mirtone 7516 Power Supply unit is designed to convert and regulate incoming electrical power to supply the necessary voltage and current levels required for various industrial electronic applications. It typically features overload protection, overvoltage protection, and short circuit protection to ensure the safety of connected devices. Common failures in this unit include capacitor failures, transformer malfunctions, and issues with the regulating circuitry. Regular maintenance and periodic testing can help prevent these failures and ensure the longevity of the power supply unit.
The Mirtone 7516 Controller is used in industrial settings to regulate and control various electronic systems. It features real-time monitoring, communication interfaces, and programmable logic control capabilities. Common failures include overheating due to dust accumulation, electrical shorts caused by moisture intrusion, and processor malfunctions from power surges. Regular maintenance and inspection can mitigate these issues and ensure optimal performance.
The Mirtone 7200 transformer is a crucial component used in industrial electronics to convert high voltage alternating current (AC) into low voltage AC. This particular model is known for its high efficiency and reliability, making it a popular choice in various industrial applications. Common failures in the Mirtone 7200 transformer include internal short circuits, overheating, and insulation breakdown. These failures can be caused by factors such as overloading, poor maintenance, and environmental conditions. It is crucial to regularly inspect and maintain the transformer to prevent such failures and ensure optimal performance.
I am repairing a door lock at an apartment block showing these symptoms.A transformer feeding the MA-485 is outputting 19.25 volts...will this harm the unit.It is a 16 volt amplifier.B when an apartment station depresses the door button the output at the amplifier terminals for the ac door reads 19.25 volts...but when it is released it only drops to 18.85 volts...which makes me think the relay is stuck on the amplifier.....bottom line do I need a new controller?C the electric strike shows a rating of 24 vac? how could this function well on a 16 volt system?It appears to have been part of this system for some time..and the caretaker has said there are problems with the system as far as people getting in without being buzzed. what is the lowest voltage a 24 volt buzzer could activate at?— Purchase or Repair:➡️ Reply Mirtone
Mirtone now owned by GE and system is 20+ years old - No manuals or hookup diagram left - please help— Purchase or Repair:➡️ Reply Mirtone
hello we did renovation and we broke a wire now we need the sqematic for it thank you— Purchase or Repair:➡️ Reply Mirtone
looking for a unitsystem is in an apartment complex. tenant can operate one entrance and hear from same however 2nd entrance does not work— Purchase or Repair:➡️ Reply Mirtone
Mircom Intercom Amplifer -MA-485 do,s not have any audio sound aplification needed to operate an apartment intercom station . I beleive when the oringinal split transformer 8v for door and 16 vac for the audio burned out because the pos+ side came lose and grounded to the neg - side the replacement was a 120- AC 24 volt 1.67 Amp 40 that I believe it damaged the amplifier circuit leading to no sound at the intercom station.Please correct me if Im wrong at my way of thinking. leewright— Purchase or Repair:➡️ Reply Mirtone
No power being supplied to the door lock. Unit is clicking when door release pressed but no power being supplies to door lock. Anyone have an answer or solution for this ?— Purchase or Repair:➡️ Reply Mirtone