Mitsubishi is a reputable manufacturer specialized in producing a wide range of industrial equipment, including motors, pumps, and automation systems. Known for their innovative technologies and high-quality products, Mitsubishi caters to various industries with reliable solutions for efficient operations. [AI]
We repair a wide range of Mitsubishi Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Mitsubishi MDS-B-CV-260 Servo Amplifier is a device used in industrial settings to control and amplify signals to drive servo motors. It features a compact design, high precision control, and a wide range of input/output options for interfacing with various control systems. Typical failures in this servo amplifier model include blown fuses, faulty capacitors, damaged power transistors, and issues with the control circuitry. These failures can result in erratic motor movement, loss of position control, or complete failure of the servo system. Regular maintenance and timely repairs are essential to ensure optimal performance and longevity of the Mitsubishi MDS-B-CV-260 Servo Amplifier.
The MITSUBISHI 16A50-04801 BT-F/L 3W H-Bridge card is designed for industrial applications requiring precise control of bidirectional current flow. This card features a high-power H-bridge configuration capable of driving motors and other high-current loads. Typical failures in this card include shorted or open power transistors, blown fuses, and malfunctioning control circuitry due to overheating or electrical spikes. Regular maintenance and proper cooling are essential to ensure reliable operation of this card.
The MITSUBISHI GT2715-XTBA Display is a human-machine interface (HMI) device designed to provide visual communication between operators and industrial control systems. The display features a 10.4-inch TFT LCD screen with an 800x600 resolution and is equipped with a resistive touch panel for user interaction. Typical failures of the MITSUBISHI GT2715-XTBA Display can include issues with the LCD screen such as dead pixels, backlight failures, or touch panel malfunctions. Other common failures may involve power supply issues, communication errors, or damage to the display housing. Troubleshooting these problems may require inspecting internal components, testing connections, and potentially replacing faulty parts to restore functionality.
The Mitsubishi AUM-1391A monitor is designed for industrial applications, providing a high-resolution display for visualizing processes and data in real-time. Its features include a large viewing area, high brightness, and rugged construction to withstand harsh industrial environments. Common failures in this monitor can include issues with the display such as pixel failure, backlight failure, or screen flickering. Electronic components such as capacitors and resistors may also degrade over time, leading to power supply issues or distorted image display. Regular inspection and maintenance can help prevent and mitigate these failures.
The Mitsubishi MR-SA22 drive unit is designed to control the speed and torque of an electric motor in industrial applications. Its features include precise speed control, high efficiency, and a compact design. Typical failures in this drive unit may include issues with power components such as IGBTs, capacitors, or control boards. These failures can lead to erratic motor behavior, overheating, or complete loss of motor control. Regular inspection and maintenance are recommended to prevent these issues.
The MITSUBISHI RZA0278 is a microprocessor-based control unit commonly used in industrial automation systems. It serves as a central processing unit for monitoring and controlling various processes within a manufacturing environment. The device features a robust design, multiple input and output ports for interfacing with sensors and actuators, and a user-friendly interface for programming and configuring the control logic. Typical failures of the MITSUBISHI RZA0278 include power supply issues, component degradation over time, communication errors, and firmware corruption. Proper maintenance and regular calibration are essential to ensure optimal performance and reliability of this control unit. If any faults occur, troubleshooting techniques and diagnostic tools should be employed to identify and rectify the issues promptly.
The MITSUBISHI RKD0546-C servo driver is a compact and high-performance electronic device used in industrial applications to control the speed and position of servo motors. It features a pulse train input for precise motion control, a built-in regenerative resistor for energy efficiency, and various protective functions to ensure safe operation. Typical failures of the MITSUBISHI RKD0546-C servo driver include power supply issues, damaged output transistors, encoder feedback problems, and cooling fan malfunctions. Regular maintenance and monitoring of the device can help prevent these common failures and ensure optimal performance.
The Mitsubishi FR-A240E-7.5K-UL is an advanced industrial electronic variable frequency drive (VFD) designed for controlling the speed and torque of AC motors in various industrial applications. This specific model has a power rating of 7.5 kilowatts and a UL certification, ensuring safety and compliance with industry standards in the United States. Key features of the Mitsubishi FR-A240E-7.5K-UL may include adjustable frequency settings, PID control, built-in braking units, overcurrent protection, and a user-friendly interface for easy programming and monitoring. It also offers various communication options for integration with different control systems. Typical failures of the Mitsubishi FR-A240E-7.5K-UL may include issues with the power capacitors, blown fuses, overheating of components, faulty input/output terminals, and software glitches. Regular maintenance, proper installation, and troubleshooting techniques are essential to ensure optimal performance and longevity of this VFD.
The Mitsubishi MR-S12-40A-Z33 servo drive is a device used to control the speed, position, and torque of a servo motor in industrial automation applications. It features a compact design, high performance, and advanced control algorithms to ensure precise motion control. Typical failures in the Mitsubishi MR-S12-40A-Z33 servo drive include power supply issues, blown fuses, overheating components, and communication failures. These failures can be caused by electrical overstress, improper wiring, or component aging. Regular maintenance and proper installation can help prevent these failures.
The Mitsubishi A0J2E-E56DT is a programmable logic controller (PLC) designed for industrial automation applications. This model features a compact design with a wide range of input and output options for interfacing with various sensors, actuators, and other devices on the factory floor. Typical failures with the Mitsubishi A0J2E-E56DT may include power supply issues, communication failures, memory errors, or hardware malfunctions due to environmental factors such as temperature fluctuations or electrical interference. Troubleshooting these issues may involve checking the connections, conducting diagnostic tests, and replacing faulty components as necessary. Regular maintenance and proper installation can help prevent potential failures and ensure reliable operation of the PLC.
ALARM : AL20 GIVEN after 3 to 4 operations.servo drive model no:MR-J2S-70A— Purchase or Repair:➡️ Reply Mitsubishi
we have servo amplifier j2s 350 but we have no servo motor so can u help pls. and also ask the alarm 16 how to reset thank you and God bless you— Purchase or Repair:➡️ Reply Mitsubishi
Dear Sir, In MR-J2S-70A servo drivedisplay showing AL - - ,Kindly help us to solve this problemRegardsR.Baskaran— Purchase or Repair:➡️ Reply Mitsubishi
Im having a trouble with a MR-J2S-70A (Servo Amplifier)Its returning the alarm 37 and i dont use the regenarative brake and the parameters are well definided for that...The alarms is still there and id like to know if there is anyway to fix it...Thanks for all the information that you can give me...— Purchase or Repair:➡️ Reply Mitsubishi
my melservo MR-J2S-70A problem, alarm AL.10.please give me know cause why? thanks— Purchase or Repair:➡️ Reply Mitsubishi
DEAR SIR I AM USING MR-J2S-10A BUT SOME OF MY DERIVES R INDICATING AL-E9I HAVE REPLACED ITS POWER MODULE BUT THE PROBLEM IS STILL THEREWILL U PLZ GUIDE METHANX— Purchase or Repair:➡️ Reply Mitsubishi
Dear sir,I want the specification of this battery(MR-BAT)so please send me early.Need to replace this battery.Thanks Mukesh Rawat— Purchase or Repair:➡️ Reply Mitsubishi
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.