Mitsubishi is a reputable manufacturer specialized in producing a wide range of industrial equipment, including motors, pumps, and automation systems. Known for their innovative technologies and high-quality products, Mitsubishi caters to various industries with reliable solutions for efficient operations. [AI]
We repair a wide range of Mitsubishi Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The MITSUBISHI RZA0414 is a compact industrial servo drive designed for precise control of motor speed and position in various industrial applications. It features a robust design, high-performance capabilities, and advanced control algorithms for optimal motion control. Typical failures in the MITSUBISHI RZA0414 may include issues with power supply components, damaged control circuits, or faults in the communication interfaces. Troubleshooting these failures often requires knowledge of power electronics, digital signal processing, and control systems theory. Regular maintenance and timely repairs are essential to ensure the reliable operation of the servo drive.
The Mitsubishi BN624E975G52A is a power supply module used in various industrial electronic equipment. Its primary purpose is to convert incoming AC voltage to the required DC voltage levels for powering the device it is installed in. The module features robust construction, high efficiency, and various protection mechanisms such as overcurrent and overvoltage protection. Typical failures of the Mitsubishi BN624E975G52A include blown fuses, failed capacitors, damaged diodes or transistors, and faulty voltage regulation circuitry. These failures can lead to a loss of power output, irregular voltage levels, or total shutdown of the equipment it powers. Regular maintenance and proper airflow ventilation can help prevent these issues.
The Mitsubishi RP21-MIF-01A-003E is a power supply unit designed for industrial applications. It provides a stable power source for various electronic devices within a system. Its features include multiple output channels, overcurrent protection, and high efficiency. Typical failures of this model include blown fuses, capacitors degradation, and power transistors malfunction. Regular maintenance and thorough testing can help prevent these issues and ensure the longevity of the power supply unit.
The MITSUBISHI AY13 Melsecnet/mini remote is a device used for remote I/O communications in industrial automation systems. It is designed to interface with MITSUBISHI's Melsecnet/mini network for reliable data exchange between PLCs and remote I/O devices. Key features of the AY13 include its compact size, high-speed data transfer capabilities, and compatibility with a wide range of MITSUBISHI PLCs. It is easy to install and configure, making it a popular choice for expanding I/O capabilities in industrial control systems. Common failures in the MITSUBISHI AY13 Melsecnet/mini remote may include communication errors, power supply issues, and connection problems. These failures can result from wiring faults, environmental factors, or component degradation over time. Regular maintenance and troubleshooting can help mitigate these issues and ensure the reliable operation of the device.
The Mitsubishi MR-S1-100-EO1 is a servo drive designed for industrial automation applications. It features a compact design, high precision control, and support for various motor types. Common failures in this model include power supply issues, blown fuses, and faults in the control circuitry. Repair typically involves troubleshooting the power supply, replacing damaged components, and re-calibrating the drive for optimal performance.
The Mitsubishi FX0-30MR is a compact programmable logic controller (PLC) designed for small to mid-sized industrial control applications. It features 16 input channels and 14 output channels, with a memory capacity of 8K steps. Common failures in the Mitsubishi FX0-30MR include power supply issues, faulty input/output modules, and damage to the central processing unit (CPU). Proper maintenance and regular inspection of the device can help mitigate these failures and ensure optimal performance.
The Mitsubishi HA-ME73 is an industrial electronic device used as a power supply module in various machinery and equipment. It is designed to convert AC power into regulated DC power to drive the operation of the connected equipment. This model features a compact design, high efficiency, and reliable performance. Common failures include short-circuits, component degradation, or overheating due to excessive loads or poor ventilation. Regular maintenance and inspection can help prevent these issues and ensure the long-term functionality of the device.
The Mitsubishi PLX-50-PMD circuit board is designed for industrial applications, featuring advanced performance and reliability. Its main purpose is to provide control and monitoring functions within a larger system. Typical features include multiple input and output channels, programmable logic capabilities, and communication interfaces for data exchange. Common failures in this circuit board may include component faults such as burnt-out resistors or capacitors, solder joint defects, or communication interface malfunctions. These issues can be diagnosed and repaired by skilled technicians experienced in industrial electronics.
The Mitsubishi RND0413-B is a power supply module primarily used in industrial electronics applications. It is designed to deliver a stable power output to various electronic components within a system. The module features overcurrent protection, overvoltage protection, and short-circuit protection to ensure the safe operation of connected devices. Common failures of the Mitsubishi RND0413-B include component degradation, blown fuses, damaged capacitors, or faulty voltage regulators. These failures can lead to erratic system behavior, intermittent power supply issues, or complete power loss. Troubleshooting typically involves checking and replacing faulty components to restore the module's functionality.
The Mitsubishi PD21B is a high-resolution display monitor commonly used in industrial applications. It features a 21-inch CRT monitor display with color imaging capabilities. typical failures of the Mitsubishi PD21B include issues with the CRT tube such as burn-in marks, image distortion, or loss of color accuracy. It may also experience power supply failures, resulting in a lack of display or flickering screen. Regular maintenance and proper handling of the monitor can help extend its lifespan and prevent common failures.
Hi there, I am currently assisting an employee with a malfunction on a Mitsubishi MR-J2-100A system. The issue is unclear, and we are in need of repair information to identify the problem and find a replacement part. Can you please provide us with detailed repair instructions or suggest a suitable replacement? We appreciate your swift response. Thank you. Best regards,β‘οΈ Reply Mitsubishi
mitsubishi mc-70β‘οΈ Reply Mitsubishi
I HOPE THATE YOU HELP US TO SOLV THES PROPLEM IN MELSERVO MODEL MR-SA502WHEN POWER ON THE ALARM COD AL32 IS DISPLAY THANK YOU FOR YOUR SUPPORTβ‘οΈ Reply Mitsubishi
When I turn on the uniformity machinery, al32 alarm appears suddenly on mrh350an servo driver.Please help me. What does it mean al32β‘οΈ Reply Mitsubishi
I HOPE THATE YOU HELP US TO SOLV THES PROPLEM IN MELSERVO MODEL MR-SA502WHEN POWER ON THE ALARM COD AL24 IS DISPLAY THANK YOU FOR YOUR SUPPORTβ‘οΈ Reply Mitsubishi
their is an error on our mitsubishi melservo-sa-r the error is alarm 52. pls reply us. thanks.β‘οΈ Reply Mitsubishi
their is an error on our mitsubishi melservo-sa-r the error is alarm 52. pls reply us. thanks.β‘οΈ Reply Mitsubishi
ALARM : AL20 GIVEN after 3 to 4 operations.servo drive model no:MR-J2S-70Aβ‘οΈ Reply Mitsubishi
we have servo amplifier j2s 350 but we have no servo motor so can u help pls. and also ask the alarm 16 how to reset thank you and God bless youβ‘οΈ Reply Mitsubishi
Dear Sir, In MR-J2S-70A servo drivedisplay showing AL - - ,Kindly help us to solve this problemRegardsR.Baskaranβ‘οΈ Reply Mitsubishi
Im having a trouble with a MR-J2S-70A (Servo Amplifier)Its returning the alarm 37 and i dont use the regenarative brake and the parameters are well definided for that...The alarms is still there and id like to know if there is anyway to fix it...Thanks for all the information that you can give me...β‘οΈ Reply Mitsubishi
my melservo MR-J2S-70A problem, alarm AL.10.please give me know cause why? thanksβ‘οΈ Reply Mitsubishi
DEAR SIR I AM USING MR-J2S-10A BUT SOME OF MY DERIVES R INDICATING AL-E9I HAVE REPLACED ITS POWER MODULE BUT THE PROBLEM IS STILL THEREWILL U PLZ GUIDE METHANXβ‘οΈ Reply Mitsubishi
Dear sir,I want the specification of this battery(MR-BAT)so please send me early.Need to replace this battery.Thanks Mukesh Rawatβ‘οΈ Reply Mitsubishi
Dear sirs. I have a Brake press Amada HFB 8025, I need a servo amplifier Melservo Mitsubishi MR-SO 403Nβ‘οΈ Reply Mitsubishi
Dear sir.We are manufacturing the electrical machinery and apparatus in Japan.Our customer is using Mitsubishi Melservo MR-SA 202U.But Alarm code 24 indicated on the display of that one.The servomotor did not move. Please estimate it for repair if it is possible. Products .....Mitsubishi AC servo MR-SA 202U AC200V50Hz 200/220V 60Hz output 14AAn early answer would be appreciated.Best regardsHitoshi SugiCompany..........................SAN SI INC.Adress...............................Yoshimi 1258-8 sakura city chiba prefecture.JAPANTel........................................+81-(0)43-487-2307Fax......................................+81-(0)43-462-2194β‘οΈ Reply Mitsubishi
: Our industrial unit, a large-scale packaging facility, has been experiencing a consistent issue with the conveyor system. The belt constantly breaks down, causing significant delays in product packaging and resulting in lost revenue. This leads to increased labor costs as were forced to manually sort packages. The current estimated repair cost is high, likely exceeding $50,000, given the complexity of the machinery involved. Given this ongoing problem, Im concerned about a long-term solution to prevent these frequent breakdowns and maintain our production capacity.:β‘οΈ Reply Mitsubishi Okk Hm40
have you a schematic diagram of this unit?have you some information to help us to fix this problem?Thank youβ‘οΈ Reply Mitsubishi
Dear Sirs, Please help us with an error code that we have on this driver MDS-B-SP-260, from a MAZAK CNC Lathe QT-200.On the display of the driver we have F6 - 36 error code, and on the machine driver malfunction.Thank you and we are waiting for your reply,Best regards,Marginean Mariusβ‘οΈ Reply Mitsubishi
the error you have is a F6 3b and it means that the unit has over heated, you can power down for 20 min and it may clear its self if not you may need a new drive als make sure the cooling fan on the side is runningβ‘οΈ Reply Mitsubishi
I have a Mitsubishi lathe model M-TC8A serial TC8A-005. I believe one of the soft keys on the controll is sticking. I have removed both the small board and large board and cannot find anything wrong with them. I am pretty sure that one is sticking because I can here the beep and all my lights flash on and off on the controll. Is there a way to test these boards? Operator Board unit MH402A-1 serial 8911007. I am not sure whick numbers on the boards are part numbers.Thanks,Tim Van Bruggen, ownerCAM Specialties, LLCβ‘οΈ Reply Mitsubishi
Dear Sir .We have a cnc sliding head machine on which the mitsubishi - AC Servo MELSERVO-SA is fitted for turret application .Macvhine has been recently imported .While installation we r facing problem on the above drive .Intially alarm AL32 over current alarm was coming ,so we tried to check the module etc so removed the card .But fitting it back we are getting this AL55.Can you help us in this regardsSunilβ‘οΈ Reply Mitsubishi
Hi there, Im interested in purchasing a Mitsubishi MDS-A-BT-6 unit. I wanted to inquire about pricing and availability as Im looking to source one quickly. Thank you!β‘οΈ Reply Mitsubishi
Urgent Downtime Report for Mitsubishi MDS-CH-CV-260Hi Team,I am writing to report an unexpected downtime caused by the Mitsubishi MDS-CH-CV-260 unit. Unfortunately, the specific issue is unknown at this time as we are still investigating the root cause.Downtime occurred today at , impacting our production schedule. We are currently working on diagnosing the problem to ensure a swift resolution and minimal disruption to operations.Please expedite the troubleshooting process and provide any relevant updates before the next shift arrives. Yourβ‘οΈ Reply Mitsubishi
Based on my previous experience, the MITSUBISHI PD21B CNC module might be experiencing intermittent power loss resulting in frequent system freezing during operation. This could indicate a potential issue with the power supply or internal connections. Further inspection by a qualified technician is recommended to identify and address the root cause of the problem.β‘οΈ Reply Mitsubishi
The Mitsubishi HF-KP23B drive or board has failed, needs immediate attention. Operating at less than optimal capacity, affecting production.β‘οΈ Reply Mitsubishi
Hello, Can you please provide more information regarding troubleshooting and potential repair options for a Mitsubishi A1SJ71AP21 Data Link Module? Thank you.β‘οΈ Reply Mitsubishi
The Mitsubishi HF-SP352 3.5kW Servo Drive experienced a malfunction, causing downtime during the last shift. It is crucial to resolve this issueβ‘οΈ Reply Mitsubishi
Our Mitsubishi FR-E720S-11 SC-EC industrial inverter unit is showing errors and not functioning properly. We need urgent repair service to get it up and running again. Please provide availability for a technician to come to our facility. Thank you.β‘οΈ Reply Mitsubishi
Our Mitsubishi MDS-B-V2-1005 servo drive unit is still down. We need assistance with this matter urgently. Please respondβ‘οΈ Reply Mitsubishi
The Mitsubishi FR-A540-22K A500 22KW Inverter is not working.β‘οΈ Reply Mitsubishi
Can the Mitsubishi MR-J2S-200B-QR141U633 Servo Drive be repaired or replaced? Trying to check this off my to-do list. Thank you.β‘οΈ Reply Mitsubishi
Mitsubishi FR-E540-5.5K-CHT inverter displaying Overcurrent Fault error code.β‘οΈ Reply Mitsubishi
Hello! I hope youre doing well. Im working on getting your Mitsubishi Electric Corporation MDS-C1-V2-1010 servo drive repaired or replaced. Before proceeding, I just wanted to confirm if it can be repaired or if a new one needs to be purchased. Yourβ‘οΈ Reply Mitsubishi Electric Corporation
Mitsubishi MC116 circuit board issue, unit not powering on. Need repair service ASAP.β‘οΈ Reply Mitsubishi
The Mitsubishi Okk HM-40 is not functioning properly.β‘οΈ Reply Mitsubishi Okk Hm-40
Hi there, I understand youre having an issue with the Mitsubishi FR-S540E-0.75K-EC unit. From what I gather, its a 0.75kW three-phase micro inverter compatible with the FR-DU04. The problem seems to be that its not working as expected. Let me know if you need further assistance.β‘οΈ Reply Mitsubishi
Mitsubishi Inverter IssueMessageHi there, I was informed that the Mitsubishi FR-E520S-1.5K-EC 1.5kW inverter is not working properly. Kindly assist with troubleshooting or repairs. Thank you.β‘οΈ Reply Mitsubishi
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.