National specializes in designing and manufacturing high-quality industrial automation equipment, including sensors, controllers, and actuators. Their innovative products are widely recognized for their reliability and precision, making National a trusted choice for automation solutions across various industries. [AI]
We repair a wide range of National Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The National Controls dnc-t1366-010 is a digital temperature controller commonly used in industrial applications with precise control requirements. This model features a 1/16 DIN size, a 3-digit LED display, and various control functions such as PID, ON/OFF, or manual. Typical failures in this controller include issues with the display, sensor input failures, or malfunctioning control outputs. Proper diagnosis and component replacement are key steps in repairing this device efficiently.
The National Controls dnc-t1354-b10 is a temperature controller designed for industrial applications. Its primary purpose is to regulate and control the temperature of a system or process. This model features a large LCD display for easy monitoring and programming, as well as a variety of input and output options for flexible connectivity with different sensors and actuators. Common failures in this model include issues with the power supply, faulty temperature sensors, or problems with the control algorithm. It is important to make sure all connections are secure and that the controller is properly calibrated to prevent inaccuracies or malfunctions. Regular maintenance and calibration are recommended to ensure optimal performance and reliability.
The National Controls dnc-t1353-010 is a digital temperature controller used in industrial applications to regulate and control temperature levels. This model features a robust industrial design, a user-friendly interface with LED display, and precise temperature control functionality. Typical failures include power supply issues, faulty temperature sensors, and malfunctioning control circuits. It is essential to conduct thorough maintenance and periodic calibration to ensure proper functioning and prevent unexpected breakdowns.
The National Controls dnc-2310-a10 is a programmable logic controller (PLC) used in industrial automation systems. It is designed to provide control and monitoring functions for machinery and processes in various industries. Key features of the National Controls dnc-2310-a10 include multiple digital inputs and outputs, analog inputs for precise control, communication ports for interfacing with other devices, and a user-friendly programming interface. Common failures of this PLC model include power supply issues, failure of input/output modules, communication errors, and software programming faults. Proper maintenance, regular firmware updates, and adherence to recommended operating conditions can help prevent these failures and ensure reliable operation.
The National Controls dnc-t2006-a10 is a temperature controller designed for industrial use. It is used to regulate the temperature of various industrial processes by interfacing with temperature sensors and heaters. Key features of the dnc-t2006-a10 include a large display for easy monitoring, multiple input and output options for compatibility with various sensors and actuators, and a user-friendly interface for convenient programming and operation. Typical failures of the National Controls dnc-t2006-a10 include issues with the temperature sensor input, malfunctioning output relays, and power supply failures. Additionally, problems with the display or control interface may also occur over time due to wear and tear. Regular maintenance and calibration can help prevent these issues and ensure the proper functioning of the temperature controller.
The National Controls SBC (Single Board Computer) is a compact industrial-grade device designed for controlling and monitoring various processes in industrial settings. This model features a robust design with high reliability and is equipped with input/output ports for connecting sensors, actuators, and other devices. Typical failures in the National Controls SBC may include power supply issues, communication errors, and component failures due to environmental factors such as heat or moisture. Regular maintenance and proper handling are recommended to ensure the longevity and optimal performance of this device.
The National Electronics model nl-pwaa-c791la is a power supply unit designed for industrial applications. It features high efficiency and reliability to provide a stable power output for various electronic devices. Typical failures include capacitor degradation, overheating of components, and circuit board issues. Regular maintenance and inspection are recommended to ensure optimal performance and longevity of the power supply unit.
The National Controls DNC-T2010-A10 is a programmable logic controller (PLC) commonly used in industrial automation applications. It features a 3.5-inch color touchscreen display for intuitive operation and monitoring of processes. This model offers multiple communication ports for easy integration with other devices and a robust construction suitable for industrial environments. Common failures in the DNC-T2010-A10 include touchscreen malfunctions, communication port issues, and power supply failures. Proper maintenance, regular backups of programming, and following manufacturer's guidelines for operation can help prolong the lifespan of the device.
The National Display Systems 90ร0081 DMX15R IG display with touch screen is a high-end industrial display unit that offers comprehensive control and monitoring functionalities. It is equipped with a touch screen interface which allows for easy navigation and input. Typical failures of this model may include touchscreen unresponsiveness, display flickering or dead pixels, and issues with the display driver or control circuitry. Regular maintenance and proper handling can help prolong the lifespan of this sophisticated display unit.
The National Controls dnc-t2003-a10 is a temperature controller commonly used in industrial applications. It features a compact design with a user-friendly interface for easy programming and operation. Common failures can include issues with the temperature sensor, display malfunction, power supply failure, or communication problems. These failures can lead to inaccurate temperature readings or loss of temperature control, impacting the efficiency and performance of the equipment. Regular maintenance and proper troubleshooting techniques can help identify and rectify these failures promptly.
My National Instruments NI PXI-1044 WELD VIBRATION CONTROLLER is not functioning properly and needs repair. Looking for a technician to help resolve the issueโ Purchase or Repair:โก๏ธ Reply National Instruments
Can the National Controls Corp E104595 Transformer Primary & Heater be repaired or do I need to buy a replacement? Trying to cross this off my to-do list.โ Purchase or Repair:โก๏ธ Reply National Controls Corp
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
๐ Rush repair shipments only โ no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
๐ฆ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.