πŸ”§ Panametrics 5222 (Ultrasonic Gauge)

The Panametrics 5222 Ultrasonic Gauge is designed for industrial applications to measure level, flow, and distance using ultrasonic waves. It features a compact design, high accuracy, and easy installation process. Common failures include transducer issues, signal processing failures, and electronic circuit faults. Regular maintenance and calibration are recommended to ensure optimal performance.

  • Part:
  • Est. Repair Price: $250.00 (est.)
πŸ”§ Panametrics 710-1253 REV.A FLOWMETER(Unknown)

The PANAMETRICS 710-1253 REV.A flowmeter is a device used to measure the flow rate of liquids in industrial processes. This model features high accuracy and reliability, along with a user-friendly interface for easy operation. Typical failures in this flowmeter may include issues with the sensors, signal processing components, or display unit. Calibration drift or damage to the sensor elements can also lead to inaccurate flow measurements. Regular maintenance and recalibration can help prevent these failures and ensure the proper functioning of the flowmeter.

  • Part: FLOWMETER
  • Est. Repair Price: $1,346.00 (est.)
πŸ”§ Panametrics MIS1-211-100000-00 (Moisture Analyzer)

The Panametrics MIS1-211-100000-00 Moisture Analyzer is designed to accurately measure moisture content in various industrial applications. It utilizes advanced technology to provide highly precise measurements with a wide range of moisture levels. Key features include a digital display for easy readout, multiple measurement modes for different materials, and a compact and rugged design suitable for industrial environments. Typical failures in this moisture analyzer may include sensor malfunctions leading to inaccurate readings, power supply issues, or display failures. Regular calibration and maintenance are recommended to ensure accurate and reliable operation.

  • Part:
  • Est. Repair Price: $4,250.00 (est.)
πŸ”§ Panametrics 6468-22-3100-S N/A(Unknown)

The PANAMETRICS 6468-22-3100-S N/A is a precision ultrasonic flow meter commonly used in industrial applications. It is designed to accurately measure the flow of liquids in various pipelines. This model features a high level of accuracy, robust construction, and ease of installation. Typical failures in this device may include issues with transducer functionality, signal processing components, or display malfunctions. Regular maintenance and calibration are recommended to ensure optimal performance.

  • Part: N/A
  • Est. Repair Price: $250.00 (est.)
πŸ”§ Panametrics 710-1340 REV A POWER SUPPLY(Unknown)

The PANAMETRICS 710-1340 REV A Power Supply is designed to provide stable and reliable power to various industrial electronic systems. It features a compact design, high efficiency, and a wide input voltage range. Typical failures in this power supply include component degradation, overheating, and voltage fluctuations leading to intermittent power output issues. Proper maintenance, such as regular inspection and cleaning, can help prolong its lifespan and ensure optimal performance.

  • Part: POWER SUPPLY
  • Est. Repair Price: $876.00 (est.)
πŸ”§ Panametrics 5222 (Ultrasonic Gauge)

The Panametrics 5222 Ultrasonic Gauge is a device used in industrial applications for non-contact level measurement. It uses ultrasonic waves to measure the distance between the sensor and the target surface, providing accurate readings for liquid or solid materials in tanks or containers. Key features include high accuracy, long service life, and compatibility with a wide range of materials. Common failures in Ultrasonic Gauges such as the Panametrics 5222 may include sensor degradation, signal interference, or electronic component malfunctions. Regular maintenance and calibration are recommended to ensure optimal performance and reliability.

  • Part:
  • Est. Repair Price: $1,300.00 (est.)
πŸ”§ Panametrics 7168-22-1111-S (FLOWMETER?) 3 CIRCULAR BD. ASSY. W/ DISPLAY & KEYPAD.(Unknown)

The PANAMETRICS 7168-22-1111-S is a flowmeter model with three circular board assemblies, featuring a display and keypad for user interface. Its primary function is to accurately measure and monitor the flow rate of a fluid within an industrial process. Typical failures in this model may include display malfunctions, keypad button failures, and electronic board component issues requiring repair or replacement. Regular maintenance and calibration are recommended to ensure optimal performance and accuracy.

  • Part: (FLOWMETER?) 3 CIRCULAR BD. ASSY. W/ DISPLAY & KEYPAD.
  • Est. Repair Price: $1,470.00 (est.)
πŸ”§ Panametrics UNKNOWN N/A(Unknown)

The PANAMETRICS UNKNOWN N/A model is a versatile industrial electronics device utilized in various applications. Its purpose is to measure and monitor different parameters such as temperature, pressure, flow, or level in industrial processes. The device features a rugged design, high accuracy, and reliability, making it suitable for harsh industrial environments. Typical failures of the PANAMETRICS UNKNOWN N/A model may include sensor malfunction, wiring issues, display errors, or power supply failures. These failures can disrupt the accurate measurement and monitoring of processes, potentially leading to operational inefficiencies or safety hazards. Regular maintenance and calibrations are recommended to ensure the proper functioning of the device.

  • Part: N/A
  • Est. Repair Price: $1,336.00 (est.)
πŸ”§ Panametrics 710-1342 REV B POWER AND OUTPUT CONTROL BOARD(Unknown)

The PANAMETRICS 710-1342 REV B Power and Output Control Board plays a critical role in regulating power distribution and managing output signals in industrial electronic systems. This board features various input and output connections, as well as integrated circuitry for power regulation and signal processing. Common failures of this board include voltage irregularities, faulty components such as capacitors or resistors, as well as damage to the circuit traces due to electrical spikes or environmental factors. Consistent monitoring and timely maintenance are essential to prevent unexpected failures and ensure the smooth operation of the electronic system.

  • Part: POWER AND OUTPUT CONTROL BOARD
  • Est. Repair Price: $590.00 (est.)

Comments for Panametrics

2 comments found.
πŸ“ Laurence Beasely said:
I have three 26DL Plus units all working fine except they wont take a charge to the battery pack. The contacts for the battery pack were loose so i resoldered them but no difference. This seems like its a common problem so I was hoping you know the probable fix and you can give me a price to fix them.
        
πŸ“ Tony said:
Hi:I need a new pack of rechargeable batteries for a 26DL panametrics..How much will cost with shipping cost to Mexico...(first class priority)ThanksTony
        
πŸ“ Tom said:
My upper screen is dim and need it replaced or repaired. Do I need to send the unit or can I buy the part.
        
πŸ“ Tom said:
My upper screen is dim and need it replaced or repaired. Do I need to send the unit or can I buy the part.
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Contact Us

πŸš‘Shop LocationπŸ› οΈ

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
πŸš‘ Rush repair shipments only β€” no walk-ins.

πŸ“žPhone

1-336-969-0110

πŸ“¦Mailing AddressπŸš›

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
πŸ“¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.