PAT is a cutting-edge manufacturer specializing in advanced precision automation technology for industrial applications. They are known for their innovative solutions that optimize production processes, increase efficiency, and ensure high-quality output in manufacturing facilities worldwide. [AI]
We repair a wide range of PAT Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The PAT Systems 2435035068 is a programmable logic controller (PLC) used in industrial automation systems. It is designed to control and monitor various processes within a manufacturing environment. This PLC offers features such as multiple I/O points, high-speed processing, and communication capabilities. Common failures in the PAT Systems 2435035068 include power supply issues, failed input/output modules, and communication errors. These failures can lead to malfunctioning of the industrial processes and require timely troubleshooting and repair by industrial electronics specialists.
The PAT DS50 / DS-50 Crane Boom Control is a sophisticated device used in industrial cranes for the precise control of the crane boom. It features advanced control algorithms and sensors to ensure safe and efficient crane operation. Typical failures in this model include sensor malfunctions, control board failures, and damage to the interface connectors. Regular maintenance and calibration are essential to prevent these issues and ensure the proper functioning of the crane boom control system.
The PAT Unknown Controller is a versatile device used in industrial automation and control systems. It is equipped with a user-friendly interface for configuring and monitoring various parameters and processes. Common issues with this controller include power supply failures, communication errors, and software malfunctions. Regular maintenance and periodic firmware updates are recommended to ensure optimal performance and prevent unexpected downtime.
The Pat DS160 is a high-precision portable digital multimeter designed for industrial use. It features a large, easy-to-read LCD display, a wide range of measurement functions including voltage, current, resistance, and capacitance, as well as temperature measurements. The multimeter is equipped with a durable and shock-resistant casing, making it suitable for use in harsh industrial environments. Typical failures with the Pat DS160 include issues with the LCD display such as pixel errors or backlight failure, measurement inaccuracies due to damaged internal components, and malfunctioning selector switches. Regular calibration and maintenance are recommended to ensure accurate and reliable performance.
The PAT DS50 Load Moment Display is used in industrial cranes to provide accurate real-time load monitoring and safety information to crane operators. It features a compact design, digital display, and intuitive interface for easy operation. Common failures include display malfunctions, sensor issues, and wiring problems. Regular calibration and maintenance are essential to ensure accurate readings and safe crane operation.
The PAT 24350300225 PCB is a printed circuit board commonly found in industrial electronic equipment. This PCB serves as the main control center for the device, managing electronic signals and providing power distribution. Typical features include various integrated circuits, capacitors, resistors, and connectors for input/output signals. Common failures in this PCB may include burnt components, faulty connections, or damage from power surges. Proper troubleshooting techniques and electronic testing equipment are necessary for diagnosing and repairing these issues efficiently.
The PAT DS-350-G amplifier is designed for industrial applications where high-quality audio amplification is required. This model features a compact and robust design with a power output of 350 Watts. It is equipped with multiple input and output options, including balanced XLR and unbalanced RCA connectors for versatile connectivity. Typical failures of the PAT DS-350-G amplifier may include power supply issues, overheating due to dust accumulation, blown fuses, or failure of the output transistors. Proper maintenance and periodic inspection of internal components can help prevent these failures and ensure the amplifier's reliable operation.
The PAT 24350300081 board is a crucial component in industrial electronics systems. Its main purpose is to facilitate communication between various electronic devices within a larger system. This board typically features multiple input and output ports, as well as integrated circuits for signal processing and data transmission. Common failures include damaged connectors, burnt-out components, and faulty integrated circuits due to excessive heat or power surges. Troubleshooting and repairing these issues often require advanced technical skills and specialized equipment.
The PAT 2435030087 board is a crucial component in industrial electronics systems. Its primary function is to manage and regulate power distribution and signal processing within the equipment. This board is equipped with various features such as overcurrent protection, voltage regulation, and data communication capabilities. Typical failures of the PAT 2435030087 board include short circuits, overheating due to component failure, or damage to the board caused by power surges or electrical faults. These failures can result in malfunctioning equipment, loss of critical data, or even damage to other connected devices. Regular maintenance and proper handling of the board can help prevent these issues.
This industrial electronic component is a circuit board with the model number PAT JPS 031-300-060-430. It is designed to serve as a crucial component in various industrial equipment. The circuit board is responsible for providing control and coordination of electronic signals within the system to ensure proper functioning. Typical failures of this circuit board include component degradation, solder joint issues, and electronic component failure due to aging or environmental factors. Regular maintenance and prompt repair can extend the lifespan of the circuit board and optimize its performance in industrial applications.
I have a malfunctioning LMI unit, moisture has entered console via broken screen and likely caused a short circuit on one of the boards. Console display powers on, but only shows a black bar with no other data or lights. Curious to know if it is worth looking at for repair. I have put together a PDF file with many photographs and further information for your assessment, please let me know where i can send it, if you are interested in taking a look at this, thanks. Scott Stevens, Mr. Lift Crane Service, Kingston ON.β Purchase or Repair:β‘οΈ Reply Pat Hirschmann
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.