Prescolite is a manufacturer specializing in high-quality industrial lighting solutions. They are known for their innovative designs, energy-efficient LED fixtures, and durable construction tailored for demanding industrial environments. [AI]
We repair a wide range of Prescolite Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Prescolite 5500-0089-01 board is a critical component in industrial lighting systems. It serves as a power control board, regulating the flow of electricity to ensure proper operation of the lighting fixtures. This board features advanced circuitry for efficient power distribution and protection mechanisms to prevent overload and short circuits. Common failures include component burnout due to power surges, damaged traces on the circuit board, and faulty solder joints. Proper maintenance and timely repairs are crucial to ensuring the longevity and functionality of the Prescolite 5500-0089-01 board.
The Prescolite 5500-0089-01 board is a critical component used in industrial lighting systems. It is responsible for controlling the power distribution and dimming functions of the lighting fixtures. The board features advanced circuitry and components to ensure reliable performance in demanding industrial environments. Typical failures of the Prescolite 5500-0089-01 board include power surges causing component damage, overheating leading to circuit board damage, and malfunctioning dimming controls. Regular maintenance and timely repairs are essential to prevent downtime and ensure the longevity of the lighting system.
The Prescolite 10-1684-02 Dimmer Control is an industrial electronic device used for controlling the intensity of lighting fixtures in various applications. It features a robust design capable of handling high power loads and providing smooth, flicker-free dimming functionality. Typical failures in dimmer controls like the Prescolite 10-1684-02 may include overheating leading to component failure, reduced dimming range, and erratic behavior due to worn-out or damaged internal components. Regular maintenance and proper ventilation can help prevent these issues and ensure optimal performance.
The Prescolite Series 7-12 is a 12-channel lighting controller designed for industrial applications. It is used to control the lighting levels in different zones or areas within a facility. This unit features individual channel dimming capabilities, allowing for precise control over the lighting intensity in each zone. Typical failures in the Prescolite Series 7-12 may include issues with channel dimming functionality, such as flickering lights or non-responsive channels. Problems with the control interface, such as buttons or knobs not functioning properly, can also occur. Additionally, power supply failures or circuit board issues may lead to overall unit malfunction. Proper maintenance and inspection of the controller can help prevent these failures and ensure optimal performance.
The Prescolite circuit board is a critical component in industrial lighting systems. It is responsible for regulating power distribution to ensure proper lighting levels. Features include voltage regulation, overload protection, and temperature control mechanisms. Typical failures include burnt components due to overloading, failed voltage regulation leading to dim or flickering lights, and overheating issues causing circuit board malfunctions. Regular maintenance and prompt repairs are crucial to ensure optimal performance and longevity of the Prescolite circuit board.
The PRESCOLITE 10-1075-01B touch pad is designed for controlling various functions within industrial electronic equipment. It provides a user-friendly interface for inputting commands and settings. The touch pad features a durable construction to withstand industrial environments and is designed for easy integration into existing systems. Typical failures include unresponsiveness to touch inputs, malfunctioning buttons, and connectivity issues. Troubleshooting may involve checking for loose connections, defective components, or software glitches.
The Prescolite 201320 circuit board is an integral component used in industrial lighting systems, particularly in Prescolite lighting fixtures. This circuit board serves as the control center for regulating the power supply to the lighting elements, ensuring proper functionality and performance. It offers features such as surge protection, dimming capabilities, and compatibility with various lighting configurations. Common failures associated with the Prescolite 201320 circuit board include power surges leading to component burnout, issues with dimming functionality, and damage to the circuit traces due to environmental factors or improper handling. Repairing these faults often involves troubleshooting the power supply, replacing damaged components, and reflowing solder joints to restore functionality. Regular maintenance and inspection can help prevent these issues and ensure the longevity of the circuit board in industrial settings.
The Prescolite 10-1684-02 Dimmer Control is a device used in industrial settings to regulate the intensity of lighting fixtures. It typically features a rotary knob or slider for manual adjustment of light levels. Common failures in dimmer controls include erratic behavior, flickering or non-responsive lights, overheating, and mechanical wear of the control knob or slider. Troubleshooting involves checking for loose connections, inspecting for burnt components, and testing the control's functionality with a multimeter. Replacement of faulty components or the entire dimmer control may be necessary to restore proper operation.
The Prescolite 10-1684-02 dimmer control is an industrial electronic component used for adjusting the lighting intensity in industrial settings. This dimmer control features a compact design, precise control over lighting levels, and compatibility with various types of lighting fixtures. Typical failures in this dimmer control include overheating due to high current loads, damage to electronic components caused by power surges, malfunctioning due to internal wiring issues, and failure of control circuits leading to the inability to adjust lighting levels. Regular maintenance and thorough inspections are recommended to prevent these issues and ensure optimal performance of the Prescolite 10-1684-02 dimmer control.
The Prescolite LCR30CD is a controller used in industrial lighting systems. It is designed to regulate the operation of lighting fixtures in industrial settings. The controller features programmable settings for controlling lighting intensity, timing, and other parameters. Common failures in this controller include power supply issues, programming errors, and component degradation due to prolonged use. Troubleshooting typically involves checking power supply parts, reprogramming settings, and replacing worn-out components.
need information on repairing control panels— Purchase or Repair:➡️ Reply Prescolite Controls
I am presently involved with a church that has a Prescolite model #HD12 dimming enclosure. This system has 12 dimming modules, 120 volt, 20 amp Prescolite control #101074-01B. The circuit breakers in the cabinet are a Square D QO double bolt-on. They are one pole 20s. The system is wired 120 volt 208 volt 3 phase; 25,200 watts 70 amp max. I have to make adjustments on this unit, but because of the age, I am not able to find the manual. I was hoping that you had printed literature on adjusting and maintaining this unit. I would also like to know if it is expandable beyond the 12 existing zones. I would also like to know if parts are available for this unit or if the dimming modules can be re-built by your company. I am also in need of some of the circuit breakers for this unit. If you could take some time and give me a call or email me back, I would very much appreciate it. The church has updated the lighting with new Prescolite incandescent light fixtures, and is requesting a readjustment of the zones. I would appreciate your help. Please call or email back. Thank you,Randy - CES Electric— Purchase or Repair:➡️ Reply Prescolite Controls
Our 10-1075-01B dimmer control has failed in our church— Purchase or Repair:➡️ Reply Prescolite Controls
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.