STI, also known as Specialty Technologies Industries, is a manufacturer specializing in innovative safety solutions for industrial applications. They are recognized for their expertise in designing and producing high-quality safety products such as industrial enclosures, safety switches, and monitoring systems to ensure a secure working environment in various industrial settings. [AI]
We repair a wide range of STI Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The STI 82291-0010 Safety Shield is designed to protect machinery operators from potential hazards by enclosing moving parts and providing a physical barrier. The Safety Shield is typically made of durable materials resistant to impact and wear. Common failures include cracks, deformation, or misalignment due to impact or regular wear and tear. Regular inspection and maintenance are essential to ensure the proper function of the Safety Shield and to prevent accidents in industrial settings.
The STI MS45D-1-AC is a safety interlock switch designed to ensure the protection of machinery and personnel by monitoring the position of guards or doors. Its main features include a robust construction, a wide operating temperature range, and dual-channel safety contacts. Typical failures of this device include contact welding due to excessive current flowing through the contacts or damage to the housing caused by improper installation or environmental conditions. Regular maintenance and periodic checks are recommended to ensure proper functioning and adherence to safety standards.
The STI MS4420X is a multi-function tester designed for testing industrial electronic equipment. It features multiple testing modes including resistance, capacitance, and diode testing. This model is equipped with a large LCD display for easy reading of measurement results. Common failures in the STI MS4420X include display malfunctions, faulty testing probes, and issues with the internal circuitry. Regular calibration and maintenance can help prevent these failures and ensure accurate testing capabilities.
The STI PA46-2-500-Q2-X light curtain is designed for use in industrial automation applications to safeguard personnel and equipment by detecting any intrusion within its protected area. It features a robust design with a high level of immunity to environmental interference, making it suitable for harsh industrial environments. Common failures in the STI PA46-2-500-Q2-X light curtain include issues with the emitter and receiver units, misalignment causing detection problems, and failures in the electrical connections. Regular maintenance and alignment checks are recommended to ensure proper functioning and safety compliance.
The STI MS46-20-870-RFN receiver is a specialized industrial device designed for receiving data signals in a controlled environment. It features a frequency range of 870 MHz with a tuning capability to ensure accurate signal reception. The receiver is equipped with RF input ports to connect to external antennas and an RS-232 interface for communication with other systems. Typical failures of this receiver may include issues with the RF input ports, such as loose connections or damage to the antenna, which can result in poor signal reception. Problems with the RS-232 interface, such as connector malfunctions or communication errors, may also occur. Additionally, electronic components within the receiver, such as capacitors or resistors, may fail over time and require replacement to restore functionality. Regular maintenance and inspection are recommended to prevent these failures and ensure optimal performance of the STI MS46-20-870-RFN receiver.
The STI MS4332BR MINISAFE B XMTR is a light curtain transmitter used in industrial safety applications. Its purpose is to emit infrared beams to detect the presence of objects within its coverage area and trigger safety protocols when interrupted. This device features a compact design, high sensitivity, and adjustable beam spacing to suit various application requirements. Typical failures include power supply issues, infrared beam alignment problems, and connector faults. Regular maintenance and calibration are recommended to ensure optimal performance and safety compliance.
The STI MS46SR-20-1045-Q1 MINISAFE 4600 Series Receiver is a safety light curtain receiver designed for industrial applications. It is used to detect and prevent unauthorized access to hazardous areas by creating an invisible detection field of infrared light beams. Features: - Compact design for easy installation - IP65 rated for dust and water resistance - RS-485 communication interface for integration with PLCs - Status LED indicators for quick diagnostics - Reset and alignment buttons for easy setup Typical Failures: - Misalignment of the light curtain causing false triggers - Damage to the infrared transmitter/receiver components - Faulty communication interface leading to integration issues - Environmental factors leading to water or dust ingress, affecting performance
The STI MG46SR-30-1215-R-A1-FD2 light curtain is typically used for perimeter guarding in industrial machinery. It consists of an emitter and receiver pair that create an infrared curtain to detect objects and personnel entering a hazardous area. The device features a range of 30 meters, with a resolution of 15 mm, and is equipped with an integrated alignment tool for easy setup. Common failures in this device include alignment issues causing intermittent beam interruptions, cable damage, and power supply problems. Regular maintenance and proper installation are crucial to ensure optimal performance.
The STI 43252-0020 controller is a versatile industrial device commonly used to regulate and control various processes in industrial applications. It features multiple inputs and outputs for interfacing with sensors, actuators, and other devices. It is equipped with a user-friendly interface for programming and monitoring operations. Common failures in the STI 43252-0020 controller include power supply issues, malfunctioning input/output modules, and software glitches. Regular maintenance and timely replacement of worn-out components can help prevent such failures and ensure the continuous operation of the controller.
The STI 43213-0010G MINISAFE B is a light curtain safety system commonly used in industrial environments to provide machine safeguarding. It features an infrared transmitter and receiver that create an array of synchronized beams, and when any of these beams are interrupted, the system sends a signal to stop the machine operation to prevent accidents. Typical failures of the STI 43213-0010G MINISAFE B include misalignment of the beams, faulty wiring connections, or component degradation over time due to environmental factors or wear and tear. Regular maintenance and alignment checks are recommended to ensure proper functioning and safety compliance.
Stillen Metal Matrix 3E9651A 6081-00 motherboard issue frequent PCB malfunctions causing production downtime. Urgent repair needed to resume assembly line operations immediately. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
The Stillen Metal Matrix motherboard 3E9651A 6081-00 isnt working. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
The Stillen Metal Matrix 3E9651A motherboard unit has malfunctioned, please troubleshoot and repair it as soon as possible. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
The Stillen Metal Matrix 3E9651A 6081-00 motherboard is not functioning correctly. Please investigate and repair as needed. Thank you. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
Stillen Metal Matrix 3E9651A 6081-00 motherboard failure. Need to troubleshoot ASAP for replacement. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
The Stillen Metal Matrix 3E9651A 6081-00 motherboard unit is not functioning. Maintenance team has reported an issue. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
The unit with the part number Stillen Metal Matrix 3E9651A 6081-00, which seems to be a motherboard, is displaying abnormal behavior in our warehouse. We are observing unusual actions and functions from this unit and believe there might be an issue with it. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
Can the Stillen Metal Matrix 3E9651A 6081-00 motherboard be repaired or replaced? Im trying to check this off my to-do list. Thank you. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
Stillen Metal Matrix 3E9651A 6081-00 motherboard not powering on. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
It seems like there might be an issue with the Stillen Metal Matrix 3E9651A 6081-00 motherboard causing the machine to act up. Im not completely sure about the exact problem, but its definitely worth looking into further to get it working properly again. Lets investigate and troubleshoot to figure out what the problem might be. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
It seems like there is an issue with the Stillen Metal Matrix 3E9651A 6081-00, possibly related to the motherboard. The machine is not functioning as expected, and further troubleshooting may be required to identify the exact problem. Ill do my best to assist you in resolving this issue. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
The Stillen Metal Matrix 3E9651A 6081-00 motherboard unit is not working. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
I have a Stillen Metal Matrix 3E9651A 6081-00 motherboard that needs repair. The unit is not functioning correctly and I need someone to fix it as soon as possible. Thank you. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
There was downtime due to an issue with the Stillen Metal Matrix 3E9651A 6081-00 motherboard. Can you provide information on what caused the problem and the timeframe it occurred in? Thank you. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
Could the Stillen Metal Matrix 3E9651A 6081-00 motherboard be repaired or purchased as a replacement part? Id like to check this off my to-do list. Thank you! β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
Im having trouble with the Stillen Metal Matrix 3E9651A 6081-00 motherboard. It seems like something has stopped working, but Im not exactly sure what. Can you help me troubleshoot this issue? β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
The Stillen Metal Matrix 3E9651A 6081-00 motherboard is showing Error Code 127 and the alarm is beeping continuously. Equipment is completely down and not responding. Please advise on next steps for repair. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
My client is facing issues with a Stillen Metal Matrix 3E9651A 6081-00 motherboard. Can you please provide information on potential repairs or solutions for this specific part number? Thank you. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
Hello, do you have a Stillen Metal Matrix 3E9651A 6081-00 motherboard available for sale or repair? Our production is currently down, and we need to keep it running. Thank you. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
Equipment ID Stillen Metal Matrix 3E9651A 6081-00Issue Motherboard malfunctionSymptom System not powering onPlease troubleshoot ASAP. β Purchase or Repair:β‘οΈ Reply Stillen Metal Matrix
We are experiencing frequent jamming issues with the STI MS4536X on the production line, leading to significant downtimes. Urgent repair is needed to restore smooth operations swiftly.β Purchase or Repair:β‘οΈ Reply STI
Request for Repair/Replacement Info for STI MS4532(T)Hi ,Im in the parts department at our facility, and a colleague needs assistance with an STI MS4532(T) that stopped working. Were trying to determine if a repair is possible or if a replacement unit is needed. Can you provide guidance on the next steps we should take?Appreciate yourβ Purchase or Repair:β‘οΈ Reply STI
Repeat Issue with STI MS46-20-435-Q1-X LIGHT CURTAINHello,I am writing to report a recurring issue with the STI MS46-20-435-Q1-X LIGHT CURTAIN unit. Based on customer returns and technician feedback, it seems that this particular unit is experiencing unidentified malfunctions. The item has been consistently reported for repair or return. Please investigate and address the root cause of this issue.Thank you for your attention to this matter.Best regards,Inventory Managerβ Purchase or Repair:β‘οΈ Reply STI
One of the drives or boards on the STI LCC-DN-DC1 safety light curtain has failed. Need to replace it to ensure proper functioning.β Purchase or Repair:β‘οΈ Reply STI
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.