Saftronics specializes in manufacturing custom industrial control systems, such as variable frequency drives and soft starters, designed to optimize the operation of electric motors in various industrial applications. They are recognized for their innovative solutions tailored to meet specific customer needs and enhance overall equipment efficiency. [AI]
We repair a wide range of Saftronics Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Saftronics CIMR-G3U4022 is a variable frequency drive (VFD) commonly used in industrial applications to control the speed of electric motors. It features a compact design, user-friendly interface, and advanced control capabilities. Typical failures in this model include power module faults, control board malfunctions, and overheating issues due to inadequate cooling. Regular maintenance and timely repairs are recommended to ensure optimal performance and longevity of the VFD.
The Saftronics CIMR-H3-7G2-E-10 is a variable frequency drive (VFD) designed for controlling the speed of an industrial motor. This model features a power rating of 7.5 horsepower and a voltage rating of 230V. It offers various control functions such as speed regulation, acceleration/deceleration control, and overload protection. Typical failures in this model include blown fuses, damaged capacitors, overheating due to poor ventilation, and power surges causing damage to the internal components. Regular maintenance, proper installation, and monitoring of input/output voltages can help prevent these issues.
The Saftronics CIMR-P5U40P7 is a compact and reliable variable frequency drive (VFD) designed for industrial applications. Its purpose is to control the speed of an electric motor, thereby allowing for energy savings and precise control in various processes. This VFD features a power rating of 5 horsepower and is equipped with built-in protection functions such as overload and overvoltage protection. Typical failures in the Saftronics CIMR-P5U40P7 may include power component failures, such as blown capacitors or burnt power modules, due to overvoltage or overcurrent conditions. Additionally, issues with the control board or failure of the cooling fan can also lead to malfunctioning of the VFD. Regular maintenance and proper installation can help prevent these failures and ensure the longevity of the device.
The Saftronics CIMR-G5U4015 is an AC drive, also known as a variable frequency drive (VFD), designed to regulate the speed and torque of an electric motor. This model features a power rating of 15 HP and is capable of controlling induction and permanent magnet motors. Typical failures with this device include overheating due to poor ventilation, power surges causing damage to the control board, and capacitor failure leading to voltage fluctuations. Regular maintenance and inspections can help prevent these issues.
The Saftronics CIMR-G3S22P2 is a variable frequency drive (VFD) designed for industrial applications. It is capable of controlling the speed and torque of three-phase motors, offering features such as adjustable frequency, voltage, and acceleration/deceleration rates. Typical failures in the Saftronics CIMR-G3S22P2 may include issues with the power modules, control board, cooling fans, or input/output terminals. Faulty wiring or overloading can also lead to system breakdowns. Regular maintenance, such as checking connections and verifying calibration, can help prevent common failures in this VFD model.
The Saftronics CIMR-PCU41P5 is a variable frequency drive used for controlling the speed of AC motors in industrial applications. It features a power rating of 5 horsepower, an input voltage of 380-480 volts AC, and various control modes like V/Hz control and vector control. Common failures in this model include overheating due to inadequate ventilation, capacitor failure leading to voltage fluctuations, and issues with the power module resulting in motor speed discrepancies. Regular maintenance and monitoring are crucial to prevent these failures and ensure the optimal performance of the drive.
The Saftronics CIMR-P5U44POE is a variable frequency drive (VFD) used in industrial applications to control the speed and torque of electric motors. It features a compact design, high efficiency, and advanced control capabilities. Typical failures in this model include power supply issues, blown fuses, overheating, and semiconductor failures. Regular maintenance and inspection are recommended to ensure optimal performance and prevent downtime.
The SAFTRONICS unknown drive is a variable frequency drive used for controlling the speed of AC motors in industrial applications. This drive is equipped with features such as adjustable speed control, overload protection, and communication interfaces for external control. Typical failures in this drive include overheating due to poor ventilation, power supply issues, and faults in control circuits. Regular maintenance and monitoring of the drive's performance are essential to prevent these issues.
The Saftronics GP10E4ST34005B1 is an AC drive used for motor speed control in industrial applications. It features a 10 horsepower capacity, 460 volts input, and 3-phase output. This drive is equipped with various protections like overcurrent, overvoltage, and undervoltage. Typical failures include blown fuses, burnt components due to overheating, and issues with the control circuitry. Regular maintenance and monitoring are recommended to ensure optimal performance and longevity of the device.
The Saftronics CIMR-F15AS3 is a variable frequency drive (VFD) designed for controlling the speed of electric motors in industrial applications. This model features a compact design and is suitable for a range of motor sizes. Common failures in this VFD model include power circuit issues such as blown fuses, failed diodes, or damaged capacitors, as well as control board malfunctions related to programming or communication errors. Regular maintenance and proper installation can help prevent these failures and ensure the VFD's reliable operation.
Urgent Downtime Report on Saftronics CIMR-H3-7G2-E-10Hello team,I need a quick resolution on an issue we faced with the Saftronics CIMR-H3-7G2-E-10 unit that caused downtime. Unfortunately, the specific problem is currently unknown. The downtime occurred at and we are urgently looking for assistance to identify and fix the issue before the next shift begins.Yourโ Purchase or Repair:โก๏ธ Reply Saftronics
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
๐ Rush repair shipments only โ no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
๐ฆ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.