Schleicher is a manufacturer specializing in the production of high-quality electrical insulation materials for industrial applications. They are known for their innovative solutions that ensure safety and reliability in demanding environments such as power generation, electric vehicles, and aerospace. [AI]
We repair a wide range of Schleicher Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Schleicher p02-a16-2 is a programmable logic controller (PLC) commonly used in industrial automation systems. It features 16 digital inputs and outputs, along with analog inputs for precise control over various processes. Typical failures in this model include power supply issues, communication failures, and failure of input/output modules. Proper maintenance and periodic testing are essential to ensure reliable operation.
The SCHLEICHER HBG2P-0301 is a compact industrial power supply unit designed for use in electronic systems. It features a robust construction, high efficiency, and precise voltage regulation. Common failures include blown fuses, capacitor degradation, and solder joint issues. Maintenance typically involves troubleshooting and replacing faulty components to restore proper functionality.
The Schleicher nt015-110 is a programmable logic controller (PLC) designed for industrial automation applications. It features 12 digital inputs and 8 digital outputs, with a voltage of 24V DC. This PLC is known for its reliable performance and robust construction suitable for harsh industrial environments. Typical failures of the Schleicher nt015-110 may include power supply issues, input/output module failures, and programming errors. Regular maintenance and thorough testing can help prevent these failures and ensure optimal performance.
The SCHLEICHER HBG2P/0301 Battenfield Display is a human-machine interface (HMI) device used in industrial applications for monitoring and controlling processes. This display features a clear and intuitive interface, allowing operators to easily visualize and interact with data from connected machines or systems. Typical failures of this device include display malfunctions, communication errors, and power supply issues. Troubleshooting these failures often involves checking the connection cables, power sources, and the internal components of the display unit.
The Schleicher URA-01A is a Universal Reversing Automatic device used in industrial applications for controlling the direction of rotation of motors. It features a compact design with intuitive interface for easy installation and operation. Common failures in the URA-01A include relay malfunctions, wiring issues, and power supply failures. Regular maintenance and periodic inspection of components are recommended to ensure reliable operation.
The Schleicher abt-01 is a programmable timer widely used in industrial applications for controlling various processes based on time intervals. It features a user-friendly interface with LED display and push buttons for easy programming. Common failures in this model include issues with the display, malfunctioning push buttons, and internal circuitry failures due to power surges or age-related degradation. Repairing these faults typically involves diagnosing the faulty components and replacing them with compatible parts to restore the timer's functionality.
The Schleicher LC-Term is a remote terminal that is used in industrial automation systems to provide visualization, control, and communication capabilities. It features a compact design, a high-resolution display, and a user-friendly interface for easy operation. Typical failures in the Schleicher LC-Term may include display malfunctions, communication errors, and power supply issues. These failures can be caused by factors such as wear and tear, environmental conditions, or electrical fluctuations. Troubleshooting and repair of the device may involve testing and replacing faulty components, checking wiring connections, or updating firmware.
The SCHLEICHER KS5076 COUNTER is a multifunctional device used for counting and displaying a variety of industrial processes. It features a digital display, versatile counting modes, and easy configuration options. Common failures include display malfunctions, count accuracy issues, and power supply problems. Repair typically involves replacing defective components or recalibrating the unit to ensure accurate counting functions.
The Schleicher DZ12-SL is a compact and versatile PLC (Programmable Logic Controller) designed for industrial automation applications. It features 12 digital inputs, 8 relay outputs, and a user-friendly programming interface. Typical failures in the DZ12-SL can include relay failure, input/output module malfunction, and power supply issues. Regular maintenance and monitoring can help prevent these common failures and ensure optimal performance.
The SCHLEICHER LCT05F contactor is designed for controlling electrical circuits in industrial applications. It features a compact design, high electrical ratings, and reliability in switching high current loads. Typical failures in this contactor include welding of contacts due to high current switching, coil burnout, and mechanical damage from excessive vibrations. Regular maintenance and inspections are recommended to ensure optimal performance and prevent unexpected downtime.
I would like to know how much is it (new):Schleicher moduleTyp USP 2I (V)Slave CPU If you need more informations, please send me a answer.I need the instructions that how I can install, use, etc.There are here in Brazil, or just for import????Thanks...Helmutβ‘οΈ Reply Schleicher
Hi can you give me a repair price fro the following. It goes by both IDs below. I do not get very good service from the OEM Schleicher.Schleicher 72943000URA-0.1A Interface Module Thank you,Mike Olszewskiβ‘οΈ Reply Schleicher
The Schleicher P03-EMS Rack Module is not working.β‘οΈ Reply Schleicher
The Schleicher P02-A16/1 Promodul-P Input Module is displaying error code E256. Equipment is not powering on despite multiple restart attempts. Please advise next steps for troubleshooting and repair.β‘οΈ Reply Schleicher