Schneider is a leading manufacturer specializing in industrial automation and control systems. They are known for producing high-quality programmable logic controllers (PLCs), motor starters, and variable frequency drives that optimize operational efficiency in manufacturing plants. [AI]
We repair a wide range of Schneider Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The SCHNEIDER ELECTRIC ATV21HD11N4 is a variable frequency drive (VFD) designed for controlling the speed of three-phase asynchronous motors. It features a power rating of 1.1 kW, a current rating of 4.4 A, and accepts input voltages ranging from 380V to 480V. This VFD offers various control modes, including scalar control and advanced flux vector control for precise motor speed regulation. Common failures in the SCHNEIDER ELECTRIC ATV21HD11N4 include power component failures due to overvoltage or overcurrent conditions, blown fuses, faulty cooling fans, and control board malfunctions. It is recommended to perform regular maintenance checks, monitoring voltage and current levels, and ensuring proper ventilation to prevent overheating and prolong the lifespan of this VFD.
The SCHNEIDER HMIGTO5310 is a human-machine interface (HMI) device designed for industrial applications. It features a 10.4-inch touchscreen display with a resolution of 800x600 pixels and is powered by an ARM Cortex A9 1 GHz CPU for fast and responsive operation. Typical failures in the SCHNEIDER HMIGTO5310 may include touchscreen malfunctions, display issues such as dead pixels or flickering, and hardware failures due to environmental factors such as dust, moisture, or temperature variations. Proper maintenance and regular calibration can help prevent these failures and ensure the device's reliable performance in industrial environments.
The Schneider 170-ADM-090-00 is a high-capacity 8-megabyte flash memory module designed for use in industrial automation systems. Its primary purpose is to store program data, configurations, and system parameters for PLCs and controllers. The flash memory module features non-volatile storage capabilities, allowing it to retain data even without power. Typical failures of the Schneider 170-ADM-090-00 flash memory module include corrupt data due to power surges or voltage fluctuations, physical damage to the module itself, or errors in writing data that may result in data loss or corruption. Regularly backing up critical data stored on the flash memory module can help prevent loss in case of a failure.
The SCHNEIDER ELECTRIC tsxpsy8500 is a programmable logic controller (PLC) designed for industrial automation applications. It features a high processing speed, a large memory capacity, and a variety of communication ports for easy integration into different systems. Typical failures of the SCHNEIDER ELECTRIC tsxpsy8500 include power supply issues, communication errors, and memory corruption due to electrical interference or component wear. Regular maintenance and proper installation can help prevent these failures. Replacing faulty components and updating firmware can often resolve these issues.
The SCHNEIDER XUS-LTR5A0520R is a Human Machine Interface (HMI) backlight designed to provide illumination for the display screen on industrial control panels or machines. It features a compact design, long lifespan, and energy-efficient LED technology. Typical failures of this HMI backlight include LED degradation over time, power supply issues, and physical damage such as broken connections or water ingress. These failures can result in dim or flickering display, uneven lighting, or total loss of backlight functionality. Regular maintenance and proper handling can help prevent these issues.
The Schneider Automation Inc tccx1730lps is a programmable logic controller (PLC) used in industrial automation systems. It features a high-speed processor, multiple communication ports, and a wide range of input and output modules for versatile connectivity. Typical failures include power supply issues, communication errors, and malfunctioning input/output modules. Troubleshooting involves conducting thorough diagnostics, checking wiring connections, and replacing faulty components as needed. Regular maintenance and firmware updates can help prevent potential failures and ensure optimal performance.
The SCHNEIDER XBTGT4330 Magelis Display is a human-machine interface (HMI) device used in industrial control systems. It features a 5.7-inch color touchscreen display with a resolution of 320x240 pixels. The device is designed to provide operators with a visual interface to monitor and control industrial processes. Typical failures of the SCHNEIDER XBTGT4330 Magelis Display include touchscreen unresponsiveness, display flickering, power supply issues, and communication errors. These failures can be caused by physical damage, electrical issues, or software malfunctions. Troubleshooting usually involves checking the connections, power supply, and updating the device's firmware.
The SCHNEIDER ELECTRIC Altivar 61 ATV61HD90Y is a variable frequency drive (VFD) used in industrial applications to control the speed of electric motors. It features a high power rating of 90 kW and is designed for heavy-duty applications. Typical failures observed in the Altivar 61 VFDs include power module failures due to overheating or power surges, control board failures caused by electrical issues or component degradation, and communication board failures that result in loss of communication with other devices. Regular maintenance, monitoring, and prompt troubleshooting are essential to prevent these failures and ensure the reliable performance of the device.
The Schneider Automation Inc TSX T107 0 is a programmable controller used for automation in industrial processes. It features a high-speed processor, ample memory for program storage, and various communication ports for connecting to other devices. Typical failures in this model may include issues with the processor, memory corruption, or communication port failures. Troubleshooting often involves diagnosing these specific components and replacing defective parts as needed.
The Schneider Automation Inc TSX P47 12 is a programmable logic controller (PLC) used for industrial automation. It features 12 digital inputs and 8 relay outputs, suitable for controlling various processes in manufacturing and production environments. Typical failures include relay contact failures, input/output module failures, and power supply issues. Regular maintenance and testing of the device are necessary to ensure optimal performance and reliability in industrial applications.
the Schneider HR 233-001-010-01-1A valve controller rack unit went down mid-shift. Please check and fix it ASAP. Thanks!β Purchase or Repair:β‘οΈ Reply Schneider
Hello, we have a Schneider MPCST52NAJ20T PC Based Operator Interface that needs repair. Can you please provide repair information as soon as possible? Thank you.β Purchase or Repair:β‘οΈ Reply Schneider
My Schneider Automation Inc ATV71HD18N4 is displaying an unknown error. Its not responding or functioning correctly. Looking for repair services as soon as possible.β Purchase or Repair:β‘οΈ Reply Schneider
Hi there, Im reaching out to inquire about the Schneider Electric LXM62DD15C21000 Lexium servo drive. Could you please let me know if this unit is still supported or if replacement parts are available for it? Thank you.β Purchase or Repair:β‘οΈ Reply Schneider Electric
My Schneider 140 DDO 353 00 output module is malfunctioning, and I need a technician to repair it quickly. Its a 32-channel 24-volt DC module, and we rely on it for our operations.β Purchase or Repair:β‘οΈ Reply Schneider
Hello, I need assistance with a Schneider Automation Inc PC-E984-255 module. The description reads Modicon Module PCE. Can you please provide information on how to troubleshoot and repair this module? Thank you.β Purchase or Repair:β‘οΈ Reply Schneider Automation Inc
The Schneider Electric LXM62DD27C21000 Lexium servo drive went down mid-shift. Need attention ASAP.β Purchase or Repair:β‘οΈ Reply Schneider Electric
Im facing issues with the Schneider Electric LXM62DD27Bxxxxx machine. Im not entirely sure what the problem is, but something seems to have stopped working correctly. Your assistance with diagnosing and resolving this issue would be greatly appreciated.β Purchase or Repair:β‘οΈ Reply Schneider Electric
We experienced downtime due to a failure with the Schneider TLD1342F312121 servo drive (1.5kW) equipped with an encoder ENCSIM1IP20 filter. This occurred at resulting in production halting. Can you investigate and provide a quick response before the next shift? Thank you.β Purchase or Repair:β‘οΈ Reply Schneider
The Schneider BMXAMI0810 module is showing no response and displaying error code 0x345. Need urgent assistance to resolve this issue as it is impacting operations.β Purchase or Repair:β‘οΈ Reply Schneider
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
π Rush repair shipments only β no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
π¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.