Sierra is a manufacturer specializing in high-precision flow measurement and control solutions for industrial applications. They are known for their innovative flow meters and controllers that meet the demanding requirements of various industries such as oil and gas, chemical processing, and water treatment. [AI]
We repair a wide range of Sierra Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Sierra Instruments 640-l13-eo-pv1-v4-nr-mp is a flow meter designed for industrial applications. It features a compact design with a digital display for accurate monitoring of fluid flow rates. Common failures in this model include sensor malfunctions, display issues, and signal processing errors. Regular calibration and maintenance are recommended to ensure optimal performance.
The Sierra Instruments 840 is a thermal mass flow meter designed for precise measurement of gas flows in industrial processes. It features a robust construction, high accuracy, and fast response time. Typical failures include sensor drift, clogging of the flow sensor, and issues with the electronics board leading to inaccurate readings. Regular calibration and maintenance are crucial to ensure optimal performance.
The Sierra Instruments 840m-3-0v1-sv1-d-v4-s4 is a precision flow meter designed for industrial applications. It features a 4-20mA output signal, a 3-inch pipe size, and a power supply of 24VDC. This model includes a digital display, valve control functionality, and a stainless steel construction. Typical failures of the Sierra Instruments 840m-3-0v1-sv1-d-v4-s4 may include issues with the digital display malfunctioning, the valve control mechanisms failing, or sensor errors causing inaccurate flow measurements. Regular maintenance and calibration are critical to prevent these common failures and ensure accurate and reliable performance.
The Sierra Instruments 840m-ce-rfq-755-2 is a precision industrial flow meter commonly used in various industrial applications. It is designed to accurately measure and control the flow rate of liquids and gases within a system. This model features a high level of accuracy, robust construction, and ease of installation and maintenance. Common failures with the Sierra 840m-ce-rfq-755-2 include sensor malfunctions, electrical wiring issues, and internal component failures due to environmental factors such as dust or moisture ingress. Regular calibration and maintenance are essential to ensure reliable and accurate flow measurements.
The Sierra Instruments 840d-m-2-v4-s4 is a high-performance electromagnetic flow meter commonly used in industrial applications. Its primary function is to accurately measure the flow rate of conductive liquids. Key features of the Sierra Instruments 840d-m-2-v4-s4 include its advanced digital signal processing capabilities, high accuracy, and robust construction suitable for demanding industrial environments. It also includes various communication interfaces for seamless integration with process control systems. Typical failures of the Sierra Instruments 840d-m-2-v4-s4 may involve issues with the electronics, such as circuit board failures, communication interface malfunctions, or power supply problems. Additionally, sensor failures or damage to the flow meter's housing can also occur, affecting its accuracy and performance. Regular maintenance and calibration are essential to ensure optimal operation and prevent potential failures.
The Sierra Instruments 840d-l-2-v4-sc is a digital flow meter designed for industrial applications. It features a high-accuracy thermal mass flow sensor and a digital interface for precise flow measurement. This model is equipped with a rugged design to withstand harsh industrial environments and is often used in gas flow applications. Common failures in the Sierra Instruments 840d-l-2-v4-sc include sensor degradation, digital interface malfunctions, and power supply issues. Regular maintenance and calibration are recommended to ensure accurate and reliable performance.
The Sierra Instruments 840d-m-2-v4-sc is a flow meter used for measuring the flow rate of liquids and gases in various industrial applications. This model features a digital display for easy readout of flow values and a compact design for easy installation. Common failures in this model include sensor malfunctions, display errors, and clogging of the flow path leading to inaccurate readings. Regular maintenance and calibration are recommended to ensure optimal performance.
The Sierra Instruments 840-m-2-v4-s4-mp is a precision flow meter designed for industrial applications. It features a high level of accuracy and repeatability, making it suitable for measuring gas and liquid flow rates in various processes. The typical failures associated with this model include sensor malfunctions, clogging of the flow path, and issues with the electronic components such as circuit boards or display screens. Regular maintenance and calibration are recommended to ensure optimal performance and reliability.
The Sierra Instruments Side Trak III is a flow meter utilized in industrial processes to measure the flow rate of liquids and gases. It features a user-friendly interface, high accuracy, and reliability. The device typically experiences failures related to sensor malfunction, signal processing issues, and electrical connections. Regular maintenance and calibration are essential to ensure accurate and precise measurements.
The Sierra Instruments 840m-3-0v1-sv1-e-v1-s1 is a precision flow meter designed for industrial applications. It features digital display with high resolution and accuracy, as well as multiple communication interfaces for data transfer and control. Common failures include sensor calibration drift, electronic board malfunctions, and communication errors. Regular maintenance and recalibration are essential to ensure accurate and reliable operation.
Good afternoon and happy Holidays . I would like to know if you can do repairs on a Sierra Power products model 7M250 Power supply . This unit is used in conjunction with a vintage ( 1990) Intel Boss I CPU as part of the PLC control for an extensive conveyor system . Later units incorporated a power supply by Astec . I do have this unit and can forward to you for your evaluation hyowever I would like to know if we have some hope for success as I have tried twice now to have this repaired and with no luck . Thank you and have a safe and Happy New YearMike ONeillโก๏ธ Reply Sierra Power Systems
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
๐ Rush repair shipments only โ no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
๐ฆ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.