Technifor specializes in providing innovative marking and traceability solutions for industrial applications. Their product range includes laser marking systems, dot peen markers, and intuitive software tailored for permanent part identification on various materials. [AI]
We repair a wide range of Technifor Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Technifor UCAR-CN31D is a control unit used in industrial settings to operate and manage various machinery and equipment. This control unit features a user-friendly interface for easy programming and monitoring of processes. Common failures in this device include power supply issues, malfunctioning input/output channels, and communication faults with connected devices. It is important to perform regular maintenance and troubleshooting to ensure optimal performance and prevent downtime.
The Technifor CN101 is an engraving unit used for industrial applications such as marking serial numbers, logos, and various codes on metal, plastic, and other materials. It features a compact design, high precision marking capabilities, and an easy-to-use interface for programmable engraving tasks. Typical failures in the Technifor CN101 may include issues with the marking head, power supply, control board, or software malfunctions. Regular maintenance and calibration are recommended to ensure optimal performance and prolong the lifespan of the equipment.
The Technifor UCAR-CN31S control unit is designed for industrial applications to control and monitor various machinery functions. This unit features a user-friendly interface for programming and adjusting parameters, as well as multiple input and output channels for connecting to different sensors and actuators. Typical failures in this control unit may include power supply issues, communication errors, or component failures leading to malfunctioning of the connected machinery. Proper troubleshooting techniques and diagnostic tools are necessary to identify and repair these faults effectively.
The Technifor ci585 is a versatile dot peen marking machine used for permanent marking on various materials such as metals, plastic, and wood. It features a compact and robust design, high-speed marking capabilities, and the ability to mark alphanumeric characters, logos, and 2D codes with precision. Typical failures include issues with the marking head, controller malfunctions, and problems with the pneumatic system. Proper maintenance and timely calibration are essential to ensure optimal performance and longevity of the Technifor ci585.
The Marking System Head, Technifor CN212CP-K model, is a crucial component used in industrial applications for marking products with precise alphanumeric or barcode information. This unit features a compact design, high-speed operation, and the ability to mark a variety of materials including metals and plastics. Common failures of the Technifor CN212CP-K include issues with the solenoid valves, clogged ink nozzles, faulty encoder sensors, and wear and tear on the marking pin or stylus. These failures can lead to inconsistent marking quality, system errors, and production downtime. Regular maintenance and timely replacement of worn components are essential in ensuring optimal performance of the Marking System Head.
The Technifor UC200/e controller is designed to control and operate industrial marking machines for engraving, etching, and dot peen marking applications. The controller features a user-friendly interface with a color touch screen for inputting messages, graphics, and specific marking configurations. It is equipped with advanced marking technologies such as serial numbering, date and time coding, and 2D code marking capabilities. Typical failures in the UC200/e controller may include touchscreen malfunctions, communication errors with marking machines, power supply issues, and software glitches. Regular maintenance and proper calibration are recommended to ensure optimal performance and longevity of the controller.
The Technifor UC200/e controller is designed to provide precise control over industrial marking machines. Its main purpose is to regulate the marking process to ensure accurate and consistent marking on various materials. Key features of the Technifor UC200/e controller include a user-friendly interface for easy programming, compatibility with different marking technologies, and the ability to store multiple marking programs. Typical failures of the Technifor UC200/e controller may include issues with the power supply, communication errors with the marking machine, and software glitches leading to erratic marking behavior. Regular maintenance, software updates, and troubleshooting techniques are recommended to ensure the optimal performance of the controller.
The Technifor XE310Cp control unit is designed for industrial applications to control marking equipment. This unit features a compact design, user-friendly interface, and compatibility with various marking technologies. Typical failures include power supply issues, firmware/software glitches, and interface communication errors. Regular maintenance and timely software updates are essential to ensure optimal performance and reliability.
The Technifor UC200 is an industrial controller unit used in a variety of applications, such as marking, engraving, and cutting machines. It features a user-friendly interface with programmable settings for precise control over the industrial process. Typical failures include power supply issues, connection failures, and software malfunctions. Regular maintenance and firmware updates can help prevent these issues and ensure optimal performance.
The Technifor CN101p/b controller is a vital component in industrial machinery, responsible for managing and coordinating various processes and functions. It features a user-friendly interface for programming and monitoring operations, offering precise control over parameters such as speed, temperature, and pressure. Common failures include circuit board damage, power supply issues, and communication errors, which may require troubleshooting and component replacement for proper functionality. Regular maintenance and proper handling are essential for maximizing the lifespan of the Technifor CN101p/b controller.
marking complete but marker does not move its home position and key feeding does not move for bitting and display shows overtime of marking unitโ Purchase or Repair:โก๏ธ Reply Technifor