Tektronix is a prominent manufacturer recognized for its high-quality oscilloscopes and test equipment utilized in the industrial sector. Their precision instruments are trusted for their accuracy and reliability in measuring electronic signals and waveforms. [AI]
We repair a wide range of Tektronix Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Tektronix 2201 is a dual trace, portable analog oscilloscope commonly used for signal analysis and voltage measurements in various industrial applications. Its key features include a bandwidth of 20 MHz, a vertical sensitivity of 5 mV/div - 5 V/div, and a maximum real time sampling rate of 50 MS/s. Typical failures in the Tektronix 2201 may include issues with the CRT display, power supply failure, faulty input channels, and intermittent triggering problems. Routine maintenance and calibration are recommended to ensure optimal performance and accuracy.
The Tektronix T912 is a mixed-signal oscilloscope renowned for its high-performance capabilities. This device allows engineers to simultaneously acquire analog and digital signals for comprehensive analysis. With a bandwidth of up to 1 GHz, it can accurately capture fast analog signals while also decoding digital data streams. Common failures in the Tektronix T912 include display malfunctions, input channel failures, and power supply issues. Regular maintenance and calibration are essential to ensure accurate measurements and reliable performance.
The TEKTRONIX G-8925-08 oscilloscope is a versatile testing instrument used for analyzing and displaying electronic signals in real-time. It features a high-resolution display, multiple input channels, and various triggering options for accurately capturing signal waveforms. Typical failures include display issues such as dim or flickering screens, faulty input channels resulting in inaccurate readings, and problems with triggering causing signal capture issues. Regular calibration and maintenance are recommended to ensure accurate performance.
The Tektronix 465B is a durable and versatile analog oscilloscope known for its high performance. It offers a bandwidth of 100 MHz and a vertical sensitivity range from 5mV to 5V/div. The device features a dual channel with delayed time base and a built-in component tester. Typical failures of Tektronix 465B might include issues with the CRT display, triggering problems, faulty power supply, or calibration drift. These failures can often be resolved through thorough troubleshooting, component replacement, and calibration adjustments.
The Tektronix T922 is a digital oscilloscope designed for industrial electronics testing and measurement. It features a high bandwidth, fast sampling rate, and a large display screen for waveform visualization. Typical failures in the T922 include power supply issues, display screen malfunctions, and problems with the input channels such as faulty connectors or damaged input circuitry. It is recommended to have a trained technician diagnose and repair these faults to ensure proper functionality and accurate measurements.
The TEKTRONIX TX-DIF63R GENERATOR 40 MHZ is a signal generator used in industrial electronics testing and development. It operates at a frequency of 40 MHz, allowing for precise and accurate signal generation. Key features of this model include multiple signal outputs, variable amplitude and frequency settings, and a digital display for easy monitoring and adjustment. Typical failures in this device may include issues with the frequency accuracy, amplitude stability, or malfunctions in the digital display interface. Common troubleshooting steps include calibrating the frequency and amplitude settings, checking for loose connections or faulty components, and ensuring proper ventilation to prevent overheating.
The TEKTRONIX TM503 mainframe is a versatile instrument that provides power and support for up to three plug-in modules. The FG 504 is a 100 MHz function generator plug-in module that offers various waveforms and frequencies for signal generation. The SCOPE/DMM module combines an oscilloscope and a digital multimeter in one unit, allowing for signal analysis and voltage/current measurements. Typical failures in these modules may include power supply issues, component degradation, or faulty connectors leading to signal distortion. Regular maintenance and calibration can help prevent these problems and ensure accurate measurements.
The Tektronix 2225 is a dual-channel analog oscilloscope designed for troubleshooting electronic circuits in industrial settings. It features a bandwidth of 50 MHz, a vertical sensitivity range of 2 mV to 5 V per division, and a maximum real-time sampling rate of 100 MS/s. Common failures in the Tektronix 2225 include issues with the CRT display such as brightness or focus problems, faulty trigger circuitry causing triggering issues, and problems with vertical or horizontal deflection circuits leading to distorted waveforms or no display at all. Regular calibration and maintenance can help prevent these failures and ensure accurate measurements.
The Tektronix 434 is a portable oscilloscope commonly utilized in industrial electronics repair. It features a dual-channel with a bandwidth of 150 MHz and a 5 ns/div time base. The device offers accurate voltage and timing measurements, making it suitable for troubleshooting electronic circuits. Typical failures include issues with the CRT display, power supply, and input channels due to aging components or improper handling. Maintenance involves regular calibration checks and preventive servicing to ensure accurate measurements and prolong the device's lifespan.
The Tektronix 214 is a portable two-channel analog oscilloscope designed for general-purpose industrial electronics troubleshooting and analysis. It features a cathode-ray tube (CRT) display with a bandwidth of up to 20 MHz, vertical sensitivity down to 5 mV/div, and sweep speeds ranging from 0.1 ฮผs/div to 0.5 s/div. The device is equipped with various triggering options, including edge, video, and line triggering. Some typical failures in the Tektronix 214 model include CRT display issues such as fading, ghosting, or complete failure, faulty triggering circuitry leading to inaccurate measurements, and problems with the vertical or horizontal deflection circuits causing distorted waveforms on the display. Regular maintenance and calibration are essential to ensure the proper functioning of this oscilloscope for accurate testing and analysis in industrial electronics repair.
Tektronix 434 displaying error code 302.โก๏ธ Reply Tektronix
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
๐ Rush repair shipments only โ no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
๐ฆ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.