Welcome to West

West is a manufacturer specializing in producing high-quality industrial valves and control systems for a wide range of applications, including oil and gas, chemical processing, and water treatment. Their products are recognized for their reliability, precision, and innovative design, making them a trusted choice for demanding industrial environments. [AI]

We repair a wide range of West Equipment.

Ask questions, or 1-336-969-0110 for faster service.

Use the search bar above to find specific manufacturers.


Why to send us your work?

To receive more information about your West industrial electronics unit, please contact us at 1-336-969-0110. We offer testing, refurbishment, and extended warranty support for West equipment. Our team of experts is here to assist you with any questions or concerns you may have.

πŸ› οΈ Common AI Repair Summaries 🏭

πŸ”§ West inst-3100 (Unknown)

The West inst-3100 is a versatile industrial process controller known for its reliable performance and advanced features. It is designed to accurately regulate temperature, pressure, flow, and other process variables in a wide range of industrial applications. The device features a user-friendly interface, digital display, multiple control modes, alarm functions, and communication options for integration into larger control systems. Common failures in the West inst-3100 include display malfunctions, control loop failures, communication errors, and power supply issues. These failures can often be diagnosed and repaired by testing individual components, such as sensors, relays, and circuit boards, to identify and replace faulty parts. Regular maintenance and calibration of the device can help prevent failures and ensure optimal performance.

  • Part:
  • Est. Repair Price: $250.00 (est.)
πŸ”§ West 3100()

The West 3100 is a versatile industrial temperature controller designed for accurate and reliable temperature control in various industrial applications. It features a user-friendly interface with programmable setpoints, PID control algorithms, and various input/output options for compatibility with different sensors and actuators. Typical failures in the West 3100 may include sensor drift, power supply issues, control relay malfunctions, or display failures. These issues can often be resolved through troubleshooting and component replacement by experienced technicians.

  • Part: 3100
  • Est. Repair Price: $550.00 (est.)
πŸ”§ West 3300()

The West 3300 is a programmable temperature controller commonly used in industrial processes for precise temperature regulation. It features a user-friendly interface with a digital display, various input and output options, and programmable control algorithms. Typical failures include power supply issues, display malfunctions, sensor failures, and communication errors. Regular maintenance and calibration are recommended to ensure optimal performance.

  • Part: 3300
  • Est. Repair Price: $610.00 (est.)
πŸ”§ West yh-40w1 (Unknown)

The West yh-40w1 is a power supply unit used in industrial electronics. It is designed to convert AC input voltage to DC output voltage to power various electronic components within a system. This model features a compact design, high efficiency, and reliable performance. Typical failures include component degradation, thermal issues, and electrical shorts, which can lead to power output issues or complete failure of the unit. Regular inspection and maintenance can help prevent such failures and ensure optimal performance.

  • Part:
  • Est. Repair Price: $992.00 (est.)
πŸ”§ West Marine 804-0440(Unknown)

The West Marine 804-0440 is an electronic bilge pump switch designed to automatically activate the bilge pump when water is detected in the boat's hull. It features a reliable solid-state sensor that triggers the pump when water level reaches a preset height. Typical failures include sensor malfunctions, wiring issues, and pump motor failures. Regular maintenance and testing are recommended to ensure proper function in critical situations.

  • Part: 804-0440
  • Est. Repair Price: $250.00 (est.)
πŸ”§ West 6100()

The West 6100 is a digital temperature controller designed for industrial applications. It features a dual-output control, highly accurate temperature sensing, and a user-friendly interface for easy programming and monitoring. Common failures in the West 6100 include display errors, relay malfunctions, and temperature sensor issues. Regular calibration and maintenance can help prevent these failures and ensure optimal performance.

  • Part: 6100
  • Est. Repair Price: $552.00 (est.)
πŸ”§ West 1208204q (Unknown)

The West 1208204q is a precision industrial temperature controller designed for regulating temperature in various industrial processes. It features advanced control algorithms, a user-friendly interface, and multiple input and output options for seamless integration into existing systems. Typical failures in the West 1208204q may include power supply issues, display malfunctions, sensor failures, or control algorithm errors. These failures can lead to inaccurate temperature regulation and inefficient process control. Regular maintenance and calibration are recommended to ensure optimal performance and prevent unexpected breakdowns.

  • Part:
  • Est. Repair Price: $992.00 (est.)
πŸ”§ West 3100 (Unknown)

The West 3100 is a precision industrial temperature controller designed to provide accurate and stable temperature control in various industrial applications. It features a digital display for easy monitoring, programmable set points for precise temperature control, and multiple input options for different sensor types. Typical failures in the West 3100 may include display malfunctions, sensor errors, and issues with the control logic. These failures can often be resolved through recalibration, sensor replacement, or troubleshooting the control circuitry. Regular maintenance and calibration are recommended to ensure optimal performance and longevity of the device.

  • Part:
  • Est. Repair Price: $776.00 (est.)
πŸ”§ West 30d()

The West 30d is a temperature controller commonly used in industrial processes. It is designed to accurately control and regulate temperature in various applications. The device features a user-friendly interface with a digital display for easy monitoring and programming. Typical failures of the West 30d may include malfunctioning temperature sensors, power supply issues, or display failures. Additionally, internal relay or communication failures can occur over time due to wear and tear. Regular maintenance and calibration are recommended to ensure optimal performance and longevity of the device.

  • Part: 30d
  • Est. Repair Price: $550.00 (est.)
πŸ”§ West m3800 (Unknown)

The West m3800 is a high-performance industrial multimeter designed for precision electrical measurements in a variety of settings. Its features include a rugged build quality, multiple measurement functions including voltage, current, resistance, and capacitance, as well as advanced data logging capabilities. Common failures in the West m3800 typically stem from damage to the input jacks, malfunctioning display, or issues with the internal circuitry resulting from overvoltage or overheating.

  • Part:
  • Est. Repair Price: $1,102.00 (est.)

Comments for West

8 comments found.
πŸ“ Joe Harvat said:
Looking for repair service for a malfunctioning Westronics CB100351-01 MUX 64 Point unit. experiencing intermittent signal loss and data transmission issues. Need assistance urgently.
πŸ“ Syed Pervez Ali said:
I have one machine vertical mill Avon with crusader II anilam opertating panel.it is not in working position before to run it I want to check it servo drive cards with servo motors , I am 30 years experienced man of working in electronics and industerial equipments.these card are in very good condition, and I am sure they are in working condition. Note:-we have 3 other CNC mill to check up.card detail Westamp INCASSY 30059-some major parts detailout put bridge devices are 29794 TO3 casing mounted on heat sink/base plateIC TL082CP 8 PinIC LM 393 X 2IC LM 1458NIC MM74C08IC UA714Transister2N3019 X 22N2222A2N4856A X2and so onMotor detailServo drive Type MT 30F4-45volts 140rpm 3100cont stall tourque 1.5 NMwith tacho 9.5 volts/1000 RPM insul class FWhat I needBefore sending it for repair I want to make sure that these really need repairing,for that I need its scematic diagram to check it and run it out from the machineif that is not possible atleast its wiring diagram to hook up it with the servomotor and techo generator and give it command signal to run the motor.
        
πŸ“ niaraki said:
dear sirswe have a colchester/master 600cnc lathe.its control system is crusader ii l anilam microprocesser control system.drive is indramat 3trm2.we bought it as a used mashie. control system dosent work.would you please help us how we can get its troublshooting plan and programming and operating instructions.looking forward to have your prompt answer best regards mr,niaraki
        
πŸ“ niaraki said:
dear sirswe have a colchester/master 600cnc lathe.its control system is crusader ii l anilam microprocesser control system.drive is indramat 3trm2.we bought it as a used mashie. control system dosent work.would you please help us how we can get its troublshooting plan and programming and operating instructions.looking forward to have your prompt answer best regards mr,niaraki
        
πŸ“ Andres Felipe Marmol Velez said:
Good morming, we are 2 Mechatronic Engineer, we write you becasuse we need a schematic diagram of one of your DC drives in order to retrofit a Bridgeport Mill Machine with Anilam Crusader II panel. Any other information will be gladly recievedThe driver is: Westamp Inc, Assy 30059.We would be very pleased if you can help us.Best regards.Andres
        
πŸ“ Harold Godwin said:
I have the same control and am in need of schematic for westamp drive so I can determine whether I have a drive problem or control problem
        
πŸ“ miguel rangel said:
I have a milling machine, eqquiped with servocontrol, it has two cards with label WESTAMP 30059-.one of them have some burned components (diodes, resistors)I dont have any information of the circuit cards.can you help me to obtain schematics or send me information about repair service?thanks
        
πŸ“ GARY LEBLANC said:
Hello,I am looking for the following circuit/test board:Westamp Inc. Assy 34235 Circuit/Test Board or Assy 34233 Rev. AThank you
        
πŸ“ RITA-DU said:
30060-116servometer drive board£¬made by Westamp £¬ 1PCSused for NV10-160
πŸ“ david suh said:
==Urgent==To whom who may concered- ==Urgent==As we are one of the user of the Westronics: Model DDR10 & Part PA100056-01 Power Supply Cards , there was power problem. The fuse was out of order & we have changed to new one(same specification from original sources) for 3 times.( Replaced the original Fuse 1 :3A 250volt/312, F with 3A 250 volt/P, F )But still no power supplying to the above card. We dont know the reason of power problem.Im wondering the above non-power supply problem is from the other parts or from this power supply cards kit. Could you advise whether we can check the other parts before we send the above parts?( model DDR 10 is connected with H.I.P Equipment( Hot Isostatic Press : ABB company)We wanna send the above parts to you for repairing after checking.Your advise will be highly appreciated.1. Is there any difference the repairing charge - DDR10 & Part PA100056-01 Power Supply Cards -$275 - only Part PA100056-01 Power Supply Cards -??2. How long it will take for repairing?3. We will send the parts by courier sevice & it will take app.3 days .4.Pls let us know the payment terms.Thanks for your kind attention & cooperations.Sincerely YoursDavid Suh/Mnaging DirectorContact InformationA-One Company456 SHIN HYUN RI, OH PO EUP, KWANG JU CITY, KYUNG KI DO, 464-895 KOREAe-mail: swissten@unitel.co.krTel+82-31-718-7274/ Fax+82-31-718-8107-----------------------------------------Replaced the original Fuse 1 :3A 250volt/312, F with 3A 250 volt/P, F
πŸ“ SAUL said:
I NEED THE DIAGRAM OF CONECTION OF THE WESTAMP CARD AW 29947TO TEST THE CARD AND THE SIGNAL IS REQUIRE TO WORKTENKS
        
πŸ“ Adan Caldera said:
Hi, I need to kow what kind of transistor its 29794 because I have one servo drive that have this transistor damage its in short.Can you help me whit this pease,Thanks.
                
πŸ“ quocphan said:
order chip TOSHIBA TF1204 QTY:40
πŸ“ Sharon Casey said:
I am a business customer with a Westronics SM100 Servo Drive unit that is not functioning properly. The unit is failing to respond to commands, resulting in erratic movements and inconsistent performance. Based on the initial assessment, the repair cost is estimated to exceed $1000 due to the complexity of the servo drive system.
πŸ“ Tasha Chapman said:
In order to comply with the Duke Energy internal Asbestos Policy, we are required to insure that no products or components containing asbestos are procured. We are contacting all Duke Suppliers of valves, pump, motors, and actuators to obtain a statement via e-mail or fax that their company does not supply asbestos containing components. This information can be e-mailed to sjbostia@duke-energy.com or faxed to (980) 373-9729. If you have questions or need clarification, please call Tasha at (704) 875-5868. Please send your response within two weeks. Thanks in advance for your cooperation.
πŸ“ Joe Sayre said:
We received new printed circuits P/N CB100161-02 for a Westronics DDR10 Recorder. The new circuits are stamped with a Rev. H. the previous Circuits were stamped with Rev.D.I need help what is the difference in design change between Rev. D and Rev.H. Are there drawings available for both board revisions showing the design changes?Thank you, Joe Sayre
        
πŸ“ Naseem Ahmad said:
Dear Sir,We would like to inform you that,Digital Data recorders has already installed at Power Plant in pakistan and I am looking source of Westronics company who can supply spare parts for DDR-3200 if yes then please complete e-mail address for company so that,we will start sending inside information.We await your quick reply/action.Best RegardsNaseem Ahmad
πŸ“ Henning Hamann said:
Hallo,I need the price and the availability for a Grounding resistance montitor, Supply Voltage AC 110V 60Hz, for 440V bus,Serieal No.: 9C09106, Type SBAG-102 Main switch borad# M4-823541Built in 1999, Manufacturer WestronicsSeobu el KoreaI Need the price for a new one.I Hope you can help me.RegardsH. HamannMehr Technical Service GmbHHamburg - Germany
        
πŸ“ stuart Rudge said:
Hello sales, are Westronics still in business? I have searched the internet but coming up with nothing apart from a few sites. I am looking for a Grounding resistance monitor type: SBDG 241.I require price & delivery for 1 piece to Southampton, UK.Regards Stuart Rudge
        
πŸ“ mariolis georgios said:
Good day Sir/Mr(s)I would like to find the manual concerning the terminals of the model above but unfortunatelly i cant.I would appreciate if you could mail me this document.Thank you in advanceMariolis Georgios
        
πŸ“ Asheen Inderpal said:
Good day,I have an enquiry to quote for the following items:1)GROUNDING RESISTANCE MONITOR(INSULATON),MANUFACTURER:WESTRONICS/SEOBU ELECTRONICS- 102,AC110V60HZ,5UA. QNTY:12)GROUNDING RESISTANCE MONITOR :CO-SBG-241D,DC19-30V.0.001-0.2MOM ALARM.QNTY-1,MADED,WESTRONICS./SEOBU ELECTRONICS3)GROUP ANNUNCIATOR:CO-SA-6PSM,24V,0.30 SEC. QNTY – 1Kindly advise if you you can supply.Regards,Ash
        
πŸ“ ACE IVEY said:
PLEASE ADVISE, I NEED INFORMATION ON PRICING AND AVAILABILITY ON THE FOLLOWING ITEM:EARTH GROUNDING RESISTANCE MONITOR, MAKE: WESTRONICSTYPE: SBAG-202MANY THANKS FOR YOUR ASSISTANCE ON THIS MATTER. I AM LOOKING FORWARD TO YOUR SOONEST REPLY.
                
πŸ“ k johnpaul said:
One of our sensor monitor out put is -5 MA against the full scale out put of 1 MA. The sensor is in alarm condition. The insulation indicator needle is in the -ve direction, kindly advise.
                        
πŸ“ Geir Mordal said:
Good morning Madames / SirsWe do have a request for following:Ground Resistance monitor.1 pc. SBAG-202 External meter FS 1 rnACan you provide us with quote / delivery time of this.Thanks in advance.Best regardsGeir Mordal
                        
πŸ“ Richard Zelm said:
Can you please tell me what the measurement voltage is that the SBAG Ground Monitor uses to monitor the insulation? Is it 24 VDC? I cant find anything in their specs that tells you what the output voltage is that monitors the insulation. Thanks!
        
πŸ“ Olejnik Leszek said:
Manual and documentation for PCB
        
πŸ“ Russell Harriman said:
Hello,I am looking to purchase a replacement unit as well as circuit board cards for The Westronics line fault detector models LFD-10P and LFD-6P. Ships Superintendent
πŸ“ Matt Saponara said:
We have an older Campbell CNC Router which has a westamp drive unit. Westamp Ser. # 756; Mod. # A7214-17F-003(041886). We cant get drive cards anymore and the repaired ones are not lasting. Can we upgrade to a newer drive unit?Matt SaponaraMaintenance ManagerHunter Marine386-462-3658
➑️ Reply Westamp - Ultradrive
πŸ“ Naresh Santal said:
Respected Sir/MadamI have purchased one power addepter ( O/P +24 V, 2A) from the market.I want to know that whether these westronics made addepters are made specialy for ALLWIN water purifires.
πŸ“ Richard Swain said:
Need 1pcs of ZA-100036-01MAGAZINE CHART
πŸ“ Cornleis (KC) Kome said:
I have a Westronics Model SVC chart recorder, ser no. 2675, (1/99) and can not find the WGetData 3.5 floppy that came with the unit, can you provide a copy of it, thanks !!!
πŸ“ Jim Lee said:
We have a Westronics 3200 Temperature scanner, S/N 1088, wed like to know if it could be repaired? It may need chart drive motor, P/N MA100018-01,circuit board, P/N CB100341-04, printhead cartridge motor, P/N MA100015, and power supply, ZB100798-01. The MUX would be sent with unit, not sure if its bad or not. It seems like most of our issue is that the printer doesnt work. Let me know if you think you might be able to repair. Thanks, Jim
πŸ“ Vision said:
Dear Sirs, We are the company in Qingdao of China, we need the machines of your company as follows:micom timer (slim type) type GTN Β¨C S1, range 0,1s Β¨C 1h 24VDC, 110/240VAC please kindly send us the quote to Qingdao as soon as possible! with kind regards
πŸ“ Cherie Disher said:
My plotter got jammed with vinyl. Since then when you turn it on and goes to the left to set itself it gets stuck and I get a Y position error. Can this machine be repaired?Thank you.
➑️ Reply Western Graphtec
πŸ“ Dmitry Gavrilenko said:
Good DayPlease give me a Users Manual for the above mentioned line falt detector. I have to modify the existing circuitry in my switchboard to make it fail-to-safe. This unit has been retrofitted and I cannot see any data onboard.thanks in advance
πŸ“ Helgert said:
Machine Issue Westronics CB100356-02 board not powering on, causing production downtime.
πŸ“ john and anna scarle said:
Hello, the Westronics 3000 is not powering on. Looking for assistance with diagnosing and fixing this issue
πŸ“ Eric Ronnebaum said:
Subject Westfalia-Surge 7750-0102-238 Downtime ReportDear Maintenance Team,I am writing to inform you about the recent downtime caused by Unit Westfalia-Surge 7750-0102-238 due to issues with the circuit board. The incident occurred at 430 PM during the afternoon shift on . The circuit board malfunction resulted in a complete halt in operations, impacting production efficiency.I kindly request immediate attention and repair of the circuit board to ensure the swift restoration of unit functionality before the next shift. Your
➑️ Reply Westfaliasurge
πŸ“ J.Y. HENRY said:
Subject Repair Inquiry for Westronics 3000 PrinterHello,I am reaching out on behalf of our client with a Westronics 3000 Printer (part number not available) that is experiencing some issues. The printer is not functioning properly and is in need of repair. Could you please provide information on the repair process, cost estimate, and turnaround time for resolving this problem?Thank you for your assistance.Best regards,
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Contact Us

πŸš‘Shop LocationπŸ› οΈ

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
πŸš‘ Rush repair shipments only β€” no walk-ins.

πŸ“žPhone

1-336-969-0110

πŸ“¦Mailing AddressπŸš›

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
πŸ“¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.