Woods is a manufacturer renowned for producing high-quality industrial-grade power tools and equipment. Specializing in durable drills, saws, and grinders, Woods is a trusted name among professionals for delivering reliable performance in demanding work environments. [AI]
We repair a wide range of Woods Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The WOODS XFC2002-0A 1HP 230V AC Drive is designed to control the speed and torque of a 1HP 230V AC motor. It is equipped with various features such as adjustable frequency, voltage, and acceleration/deceleration settings. Typical failures in this model include power supply issues, blown fuses, overheating, and faulty control circuitry. Regular maintenance and timely troubleshooting can help prevent these issues and ensure efficient motor control.
The Woods AFC202-0B2S is a frequency inverter used to control the speed of an electric motor in industrial applications. It features a compact design, easy installation, and customizable parameters for various motor types. Typical failures include power supply issues, overheating, and failure of control circuits or communication modules. Regular maintenance and monitoring are recommended to ensure optimal performance and longevity of the device.
The Woods WFC4060-0B is a variable frequency drive (VFD) used for controlling the speed of induction motors in industrial applications. It features a compact design, easy installation, and a wide range of voltage and power options. Common failures include overheating due to inadequate ventilation, capacitor failure, and power surges causing damage to the internal components. Regular maintenance and proper installation can help prevent these issues.
The Woods U100 is a universal digital meter primarily used for measuring electrical parameters in industrial applications. It features a large LCD display for easy reading of measurements such as voltage, current, resistance, and continuity. Common failures include malfunctioning display, inaccurate readings, and issues with the input jacks. Proper calibration and regular maintenance are essential to ensure accurate and reliable measurements.
The Woods WFC2001-0HT is a modular frequency converter designed for applications in industrial settings. It features a compact design, variable frequency control, and high efficiency. Common failures include overheating due to poor ventilation, component degradation, and electrical surges. Proper maintenance and monitoring can help prevent these issues and ensure the device's optimal performance.
The Woods WFC4015-0AHT is a frequency converter used in industrial applications to convert a fixed-frequency AC power supply into a variable-frequency output. It features a compact design, digital display for easy monitoring of operating parameters, and adjustable frequency and voltage settings for customized usage. Common failures in the Woods WFC4015-0AHT include failures in power transistors, capacitor issues, display malfunctions, and cooling fan failures. Ensuring proper cooling and maintenance of components can help prevent these failures.
The Woods WFC4003-0A is an industrial frequency converter designed to convert electrical power from one frequency to another, allowing compatibility between different electrical systems. It features a compact design, precise frequency conversion, and robust construction suitable for industrial applications. Typical failures in this model include power supply issues, overheating, and component failures leading to frequency inaccuracies or complete unit failure. Regular preventive maintenance and timely repairs are essential to ensure the reliable operation of the Woods WFC4003-0A.
The Woods WFC5007-5C is a programmable logic controller (PLC) designed for industrial automation applications. It features 24 digital inputs, 16 digital outputs, and 4 analog inputs. The device can be programmed using ladder logic programming language to control various industrial processes. Typical failures with the Woods WFC5007-5C PLC include power supply issues, faulty input/output modules, and programming errors. Overheating and electrical surges are common culprits for malfunctions in this device. Regular maintenance, proper grounding, and programming checks can help prevent such failures.
The Woods PC 137H is a power strip timer commonly used for automated control of devices in industrial settings. It features multiple outlets that can be programmed to turn on or off at specific times, allowing for energy conservation and improved operational efficiency. Common failures include circuit board malfunctions, timer mechanism issues, and power supply failures. Regular maintenance and proper programming are crucial to ensure its reliable operation.
The Woods XFC4003-0C is a frequency counter designed for industrial electronic applications. It is equipped with a digital display to provide accurate frequency measurements, typically ranging from 10 Hz to 400 MHz. Common features include selectable input impedance options, such as high or low impedance, and various trigger modes for accurate frequency tracking. Typical failures in the Woods XFC4003-0C may include display malfunctions, inaccurate frequency readings due to component degradation, or issues with input impedance settings. Regular maintenance and calibration are recommended to prevent these failures and ensure the device's accuracy and reliability.
Hi there, I am reaching out on behalf of my client who has a Woods wfc2007-5c unit that is currently experiencing an unknown issue. We are looking to get more information on the problem and possible repair solutions for this particular model. Could you please provide us with some guidance or schedule a diagnostic appointment? Thank you for your assistance. Best regards,β‘οΈ Reply Woods
Hello, Im currently assisting a colleague who has a Woods wfc2007-5c that has stopped working. We are in need of repair or replacement information to resolve the issue. Can you please provide guidance on how to proceed or source a replacement part? Yourβ‘οΈ Reply Woods
Can the Woods J500 be repaired or bought? Im trying to check this off my to-do list.β‘οΈ Reply Woods