Agilent Technologies is a renowned manufacturer in the industrial sector, recognized for their high-precision measurement instruments and advanced technologies. They specialize in producing cutting-edge equipment used in laboratories, research facilities, and manufacturing plants for a wide range of applications, including chemical analysis, life sciences, and electronics testing. [AI]
We repair a wide range of Agilent Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Agilent 0950-3276 smartcard is a device used in electronic test and measurement applications. This smartcard typically contains calibration and configuration data for Agilent equipment, allowing for easy access to specific settings and parameters. Common failures of the Agilent 0950-3276 smartcard include data corruption, physical damage to the card, or compatibility issues with the equipment it is intended for. Regular maintenance and careful handling can help prevent these issues.
The Agilent G4407-65430 controller is a device primarily used in industrial automation applications. It features a high level of precision and reliability in controlling various parameters such as speed, temperature, pressure, and flow. This controller typically communicates with other devices in a control system through various communication protocols such as RS-232, RS-485, or Ethernet. Common failures in the Agilent G4407-65430 controller can include power supply issues, communication failures, and malfunctioning input/output modules. These failures can be caused by electrical surges, component aging, or improper installation. Troubleshooting these issues usually involves testing and replacing faulty components or modules to ensure the proper functioning of the controller.
The Agilent 6652a is a precision programmable DC power supply designed for industrial and laboratory use. It offers high accuracy and stability with a wide range of output voltage and current capabilities. Typical failures in the Agilent 6652a include issues with the power supply unit, such as blown fuses, faulty capacitors, or damaged voltage regulators. Common issues also include problems with the control interface or malfunctioning digital display. Regular calibration and maintenance are recommended to ensure optimal performance and reliability.
The Agilent U1602B WireScope 350 is a high-performance handheld cable tester designed for testing and certifying twisted pair cabling installations up to 350 MHz. It features advanced measurement capabilities such as length, insertion loss, NEXT, PSNEXT, ACR, PSACR, and resistance measurements. Typical failures associated with the Agilent U1602B WireScope 350 include issues with the display screen, battery, calibration accuracy, and connectivity problems. Regular calibration and maintenance are essential to ensure accurate and reliable performance.
The Agilent 6652A Oscilloscope is a versatile instrument used for measuring and analyzing electrical signals in various industrial applications. It features a high bandwidth and sampling rate, allowing precise capture of signal details. Additionally, it offers advanced triggering options, memory depth, and signal analysis capabilities. Typical failures in the Agilent 6652A Oscilloscope include problems with the display screen, malfunctioning knobs or buttons, issues with the power supply or input channels, and failures in the signal processing circuitry. Regular calibration and maintenance are essential to ensure accurate and reliable operation of this oscilloscope.
The Agilent 53132A PG #11 is a time interval analyzer with built-in sources that provide fast, high-precision measurements. Its primary purpose is to accurately measure and analyze time intervals in various electronic systems. This model features a high-contrast display for easy reading, versatile trigger capabilities, and multiple measurement modes for enhanced functionality. It also offers a wide measurement range and excellent resolution, making it suitable for a wide range of applications in the industrial electronics field. Typical failures in the Agilent 53132A PG #11 include issues with the display screen, malfunctioning trigger circuits, and problems with the internal sources. Additionally, failures related to power supply components and input/output interfaces may also occur. Regular maintenance and calibration are recommended to ensure optimal performance and extend the lifespan of the device.
The Agilent 6654A is a system DC power supply designed for industrial applications. Its primary purpose is to provide a stable and reliable source of DC power to various electronic devices and circuits. The unit features adjustable output voltage and current, as well as overvoltage and overcurrent protection mechanisms to prevent damage to connected equipment. Typical failures of the Agilent 6654A may include component wear leading to power output fluctuations or even complete failure, defective temperature sensors causing overheating issues, and malfunctioning protection circuits causing false triggering of safety features. Regular maintenance and recalibration can help prevent such failures and ensure the unit's longevity and performance.
The Agilent L9534 is a high-performance electronic load module designed for testing power supplies, batteries, and fuel cells. This device features a wide operating voltage and current range, allowing for precise and flexible testing of various power sources. Typical failures include failed input/output connectors, blown fuses, and damaged circuit components due to overvoltage or overcurrent conditions. Regular calibration and component testing are recommended to ensure accurate and reliable operation.
The Agilent E3615a is a DC power supply designed for industrial and laboratory use. It provides stable and accurate DC voltage and current outputs for powering electronic circuits and devices. The device features adjustable voltage and current settings, overvoltage protection, and a digital display for monitoring output values. Typical failures include blown fuses, damaged output transistors, and malfunctioning control circuitry. Proper maintenance and calibration are crucial for ensuring the device's reliability and accuracy.
The AGILENT L9534 SMARTCARD is a programmable smart card that is commonly used in industrial applications for data storage and processing. It features a microcontroller with EEPROM memory, which allows for secure data storage and retrieval. This smart card is compatible with various communication interfaces such as SPI, I2C, and UART for easy integration with different systems. Typical failures of the AGILENT L9534 SMARTCARD include issues with data corruption, communication errors, and physical damage to the card. These failures can be caused by improper handling, environmental factors, or electrical surges. In some cases, reprogramming the smart card or replacing it with a new one may be necessary to resolve these issues.
I would like to request a quote for the following repair services if available:Agilent Infiniium 54820A Defect: CH 2 will not change resolution from 200mV to 250mV signal still small and readings are not accurateT-BERD 211 Defect: no communicacion RS232 with PCโก๏ธ Reply Agilent
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
๐ Rush repair shipments only โ no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
๐ฆ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.