Mirtone specializes in the design and production of high-quality fire alarm and communication systems for industrial and commercial applications. They are recognized for their innovative solutions and reliable products that ensure safety and security in various environments. [AI]
We repair a wide range of Mirtone Equipment.
Ask questions, or 1-336-969-0110 for faster service.
Use the search bar above to find specific manufacturers.
The Mirtone 79042 board is a component commonly used in industrial electronic systems for fire alarm and communication purposes. It features multiple input and output connections for interfacing with various sensors, alarms, and communication devices. Typical failures include power supply issues, damaged components due to electrical surges, and communication interface failures. Proper maintenance and regular inspection are recommended to ensure optimal performance and reliability.
The Mirtone 79045 board is a crucial component used in industrial fire alarm systems. Its primary function is to control and monitor various aspects of the fire alarm system, such as sensors, horns, and strobes. The board features multiple input and output connections for interfacing with different devices within the system. Some common failures associated with the Mirtone 79045 board include power supply issues, communication failures, and component degradation due to environmental factors. It is important to regularly inspect and maintain this board to ensure the proper functioning of the fire alarm system.
The Mirtone 7200 circuit board is a critical component in fire alarm systems in industrial applications. It is responsible for processing signals from various sensors and activating alarms in case of fire incidents. The board features high-quality components and precise signal processing capabilities to ensure reliable operation. Typical failures include burnt-out components, short circuits, and faulty connections due to aging or environmental factors. Regular maintenance and timely repairs are essential to ensure the proper functioning of the Mirtone 7200 circuit board and the overall fire alarm system.
The Mirtone OSP-218 circuit board is a crucial component used in fire alarm systems to monitor and control various functions. It features multiple input and output connections for interfacing with detectors, alarms, and other system components. Common failures in this circuit board include damaged traces, blown components, and power supply issues, often resulting from power surges or improper installation. Regular maintenance and inspection can help prevent such failures.
The Mirtone 79045-2 Fire Alarm Panel is a critical component in industrial and commercial buildings, designed to detect and alert occupants of a potential fire emergency. Its features include multiple detection zones, alarm output relays, and battery backup for uninterrupted operation in case of power failure. Common failures in these panels can include faulty sensors, wiring issues, power supply failures, and malfunctioning alarm output circuits. Proper maintenance, periodic testing, and prompt repairs are essential to ensure the reliable operation of the fire alarm system.
The MIRTONE 401 Flow Monitor is a device designed to monitor and display flow rates in industrial piping systems. It features a digital display that indicates flow rates in gallons per minute (GPM) or liters per minute (LPM). This monitor is equipped with flow sensors that can be easily integrated into existing piping systems to provide accurate and real-time monitoring of flow rates. Common failures of the MIRTONE 401 Flow Monitor include issues with the flow sensors, such as clogging or damage, which can result in inaccurate flow rate readings. Additionally, problems with the digital display, such as malfunctioning LEDs or faulty connections, may also occur. Regular maintenance and calibration of the device are essential to ensure accurate and reliable performance.
The Mirtone 71269F Fire Alarm Panel is a critical component in fire detection and alarm systems. Its primary function is to monitor input devices such as smoke detectors and heat sensors, as well as manual pull stations, and to alert building occupants in the event of a fire emergency. The panel typically features LED indicators for system status, audible alarms, and various programmable settings for customization. Common failures in fire alarm panels like the Mirtone 71269F may include power supply issues, faulty wiring connections, corrosion on circuit boards, or defective components such as relays or integrated circuits. Regular maintenance and prompt troubleshooting are essential to ensure the reliable operation of the fire alarm system.
The Mirtone 79021/50 is a fire alarm panel designed to monitor and control fire detection devices within a building. It features LED indicators for alerting users to alarm or fault conditions, as well as a user-friendly interface for system configuration and testing. Common failures in fire alarm panels include power supply issues, faulty circuitry, and communication errors with connected devices. Regular maintenance and testing are essential to ensure the proper functioning of the unit.
The Mirtone 79046 is a Class B smoke detection module used in fire alarm systems. Its purpose is to detect smoke in commercial or industrial environments and communicate this information to the fire alarm control panel. The module features two-wire connection, LED indicators for power and alarm status, and a built-in sounder for local notification. Typical failures of the Mirtone 79046 Class B smoke detection module include sensor contamination, faulty wiring connections, power supply issues, and component degradation over time. Regular maintenance and testing are recommended to ensure proper functioning of the device.
The LED Alert module, model Mirtone 79045-2, is an essential component used in industrial settings to provide visual alerts and notifications. Its main purpose is to offer quick and easily recognizable visual cues to signal specific events or situations to operators and workers. The module typically features bright, high-intensity LEDs that are designed for maximum visibility in noisy or busy environments. Common failures in LED Alert modules include burnt-out LEDs, corrosion in the electrical connections, and power supply issues. Proper maintenance, periodic testing, and prompt replacement of faulty components are essential to ensure the reliable operation of the LED Alert module.
Hi...I have one customer with no voltage to the door striker but have confirmed the striker works. Transformer is ok! Do you have the parts for this, relay etc to ship so I can repair it or do you have a re-conditioned unit for sale. The seniors in thecomplex want it yesterday..Can you help?R.Jim WhiteMelfort, Sask.Canadaβ‘οΈ Reply Mirtone
I am repairing a door lock at an apartment block showing these symptoms.A transformer feeding the MA-485 is outputting 19.25 volts...will this harm the unit.It is a 16 volt amplifier.B when an apartment station depresses the door button the output at the amplifier terminals for the ac door reads 19.25 volts...but when it is released it only drops to 18.85 volts...which makes me think the relay is stuck on the amplifier.....bottom line do I need a new controller?C the electric strike shows a rating of 24 vac? how could this function well on a 16 volt system?It appears to have been part of this system for some time..and the caretaker has said there are problems with the system as far as people getting in without being buzzed. what is the lowest voltage a 24 volt buzzer could activate at?β‘οΈ Reply Mirtone
Mirtone now owned by GE and system is 20+ years old - No manuals or hookup diagram left - please helpβ‘οΈ Reply Mirtone
hello we did renovation and we broke a wire now we need the sqematic for it thank youβ‘οΈ Reply Mirtone
looking for a unitsystem is in an apartment complex. tenant can operate one entrance and hear from same however 2nd entrance does not workβ‘οΈ Reply Mirtone
Mircom Intercom Amplifer -MA-485 do,s not have any audio sound aplification needed to operate an apartment intercom station . I beleive when the oringinal split transformer 8v for door and 16 vac for the audio burned out because the pos+ side came lose and grounded to the neg - side the replacement was a 120- AC 24 volt 1.67 Amp 40 that I believe it damaged the amplifier circuit leading to no sound at the intercom station.Please correct me if Im wrong at my way of thinking. leewrightβ‘οΈ Reply Mirtone
No power being supplied to the door lock. Unit is clicking when door release pressed but no power being supplies to door lock. Anyone have an answer or solution for this ?β‘οΈ Reply Mirtone
Mir-tone Assy. 72024100 motherboard not powering up, no lights or display. Need repair service ASAP.β‘οΈ Reply Mirtone
My customer has an 8 floor.20 suite/floor mirtone system with pull stations in all suites.each suite is decoded in the mirtone on each floor and then on the first and second floor there are two master stations to decode the floor number. The system is only local to the caretaker.The owners want all the suites to be monitored through the security company sekuretec in winnipeg iF YOU HAD SCHEMATICS OF THE EC200 IT WOULD BE HELPFUL.β‘οΈ Reply Mirtone
please send manual mirtone ec200 but tone stop laps time small please send me why do it the time = laps time long.ThanksJaimerais savoir comment faire pour mettre le signal sonore sans interruption automatique. Cest a dire que je veux larreter moi-meme. Merciβ‘οΈ Reply Mirtone
I require of support and that contacts a distributor to me of mirtone in the city of Mexico thanksβ‘οΈ Reply Mirtone
We have a mirtone EC200 installed in a 36 unit Sr. Care complex with standard call switches in each unit and a call light outside the entry door on the exterior of each unit. The system is powered with a 24VAC transformer. We would like to replace the outdoor lights with a Horn/Strobe combination unit to provide for better indication of the call request for emergency personnel. QUESTION: Can we replace the 24VAC transformer with a 24VDC power supply so that we can use 24VDC horn/strobes on the exterior of the buildings? All field wiring would be compatible with this but I wasnt sure if the EC200 would operate on a DC supply. 24VDC Horn/strobes are readily available but 24VAC ones (especially when they have to be weatherproof too) are extremely hard to find and are very expensive. Any input would be appreciated.β‘οΈ Reply Mirtone