Welcome to Sick

Sick, a prominent manufacturer in the industrial sector, specializes in producing cutting-edge sensor technologies for various applications. Their products are known for their precision, reliability, and innovation in helping businesses improve automation and efficiency in their operations. [AI]

We repair a wide range of Sick Equipment.

Ask questions, or 1-336-969-0110 for faster service.

Use the search bar above to find specific manufacturers.


Why to send us your work?

To receive more information about your Sick industrial electronics unit, please contact us at 1-336-969-0110. We offer testing, refurbishment, and extended warranty support for Sick equipment. Our team of experts is here to assist you with any questions or concerns you may have.

πŸ› οΈ Common AI Repair Summaries 🏭

πŸ”§ Sick DME5000-322 NET CONNECTOR(Unknown)

The SICK DME5000-322 NET CONNECTOR is commonly used in industrial automation systems to connect various sensors and devices in a network setup. It serves as a communication interface that enables the exchange of data between different components within the system. Key features of the SICK DME5000-322 NET CONNECTOR include its robust design to withstand harsh industrial environments, easy installation, and configuration for seamless integration into existing networks. It is capable of supporting multiple communication protocols, ensuring compatibility with a wide range of devices. Typical failures in the SICK DME5000-322 NET CONNECTOR may include issues such as communication errors, physical damage due to environmental factors, or electronic component failure. Regular maintenance, proper installation, and following manufacturer guidelines can help mitigate these failures and ensure the optimal performance of the device.

  • Part: NET CONNECTOR
  • Est. Repair Price: $2,550.00 (est.)
πŸ”§ Sick 1028934 / S30A-4011BA POWER SUPPLY MODULE(Unknown)

The SICK 1028934 / S30A-4011BA power supply module is designed to convert input voltage into a regulated output voltage suitable for industrial applications. This model is equipped with features such as short-circuit protection, overvoltage protection, and thermal protection to ensure the safety and reliability of the connected devices. Typical failures with this power supply module include component degradation, input voltage spikes, and output voltage fluctuations. Proper maintenance and periodic inspection can help prevent these failures and ensure the longevity of the device.

  • Part: POWER SUPPLY MODULE
  • Est. Repair Price: $646.00 (est.)
πŸ”§ Sick FGSS1350-211 LIGHT CURTAIN(Unknown)

The SICK FGSS1350-211 light curtain is a safety device used to detect and protect personnel or equipment in industrial settings by creating an invisible barrier of light beams. It features a compact design with a detection range of up to 5 meters and a resolution of 30 mm. Typical failures in the SICK FGSS1350-211 light curtain include beam interruptions due to dirt, misalignment, or physical damage. Additionally, failures in the control unit or power supply can also occur, leading to malfunctions in the device's operation. Regular maintenance and cleaning are crucial to prevent these issues and ensure the proper functioning of the light curtain.

  • Part: LIGHT CURTAIN
  • Est. Repair Price: $3,010.00 (est.)
πŸ”§ Sick CLV430-1010 N/A(Unknown)

The SICK CLV430-1010 N/A is a fixed mount barcode scanner commonly used in industrial settings for automated identification and data capture applications. It features a high scanning speed and a wide reading range, making it suitable for fast-paced environments. Typical failures with the SICK CLV430-1010 N/A may include issues with the laser diode, the motor drive system, or the interface communication ports. It is important to regularly check and maintain this device to ensure optimal performance and longevity.

  • Part: N/A
  • Est. Repair Price: $250.00 (est.)
πŸ”§ Sick FGSS1350-11 LIGHT CURTAIN(Unknown)

The SICK FGSS1350-11 light curtain is a safety device commonly used in industrial automation to safeguard personnel and equipment. It features a series of synchronized infrared beams that create a protective field, detecting any object or person that breaks the beam pattern. Typical failures of the SICK FGSS1350-11 light curtain include alignment issues, dirty lenses or emitters, power supply problems, and electronic component failures. Regular maintenance, such as cleaning and alignment checks, can help prevent these issues and ensure the proper functioning of the device.

  • Part: LIGHT CURTAIN
  • Est. Repair Price: $1,536.00 (est.)
πŸ”§ Sick CL430-0010 TEST UNIT(Unknown)

The SICK CL430-0010 test unit is designed for the evaluation and testing of SICK safety light curtains. It includes features such as a digital display for easy monitoring of status and functions, as well as controls for adjusting settings. Typical failures of the SICK CL430-0010 test unit include display malfunctions, button failures, and power supply issues. Regular maintenance and calibration are recommended to ensure accurate testing results.

  • Part: TEST UNIT
  • Est. Repair Price: $250.00 (est.)
πŸ”§ Sick DME2000-000 N/A(Unknown)

The SICK DME2000-000 N/A is a laser distance sensor designed for industrial applications. It features a measuring range of up to 30 meters with high accuracy and repeatability. The sensor utilizes time-of-flight technology to measure distances based on the time it takes for the emitted laser light to reflect off the target object and return to the sensor. Typical failures of the SICK DME2000-000 N/A include laser emitter degradation, faulty distance measurement readings due to contamination on the sensor's lens, and issues with the electronics board causing inaccurate measurements. Regular calibration and maintenance are recommended to ensure proper functioning and accuracy of the device.

  • Part: N/A
  • Est. Repair Price: $450.00 (est.)
πŸ”§ Sick 10207003()

The Sick 10207003 is a photoelectric proximity sensor used for detecting objects or individuals within its operating range. Its features include a compact design, high sensing range, and reliable performance in various industrial applications. Common failures with this sensor may include issues with the optics, electronic components, or misalignment, leading to inaccurate readings or failure to detect objects. Regular maintenance and calibration are recommended to ensure optimal performance.

  • Part: 10207003
  • Est. Repair Price: $550.00 (est.)
πŸ”§ Sick CLV412-0010 N/A(Unknown)

The SICK CLV412-0010 is a barcode scanner commonly used in industrial applications. This model is designed to read and decode various types of barcodes quickly and accurately. It features a compact design, high-speed scanning capabilities, and versatile connectivity options. The key features include RS-232 and RS-422 interfaces, a red LED light source, and a scanning rate of up to 600 scans per second. Typical failures with the SICK CLV412-0010 include issues with the motor assembly, power supply failure, and connector problems. Additionally, dirt or dust accumulation on the barcode reader lens may lead to reading errors. Regular maintenance and cleaning can help prevent these common issues.

  • Part: N/A
  • Est. Repair Price: $250.00 (est.)
πŸ”§ Sick S30B-2011BA LASER SCANNER(Unknown)

The SICK S30B-2011BA Laser Scanner is a device used in industrial automation applications for detecting objects and measuring distances. It utilizes laser technology to provide accurate distance measurements and can be integrated into various control systems. Features: 1. Laser-based detection technology 2. Wide detection range 3. High accuracy in distance measurement 4. Integration capabilities with control systems Typical Failures: 1. Laser module failure leading to inaccurate distance measurements 2. Communication issues with control systems 3. Wear and tear on mechanical components such as bearings 4. Environmental factors affecting sensor performance

  • Part: LASER SCANNER
  • Est. Repair Price: $3,416.00 (est.)

Comments for Sick

1 comments found.
πŸ“ John wallace said:
Im sorry to hear about the issue with your machine. It seems like something has stopped working, but Im not sure exactly what. I recommend contacting our technical support team for further assistance with your SICK XC40E-0603A0A0AAA0.
πŸ“ marilyn melton said:
I have observed a unit in the warehouse that is not functioning normally. It is displaying unusual behavior, although I am unsure of the specific name of the unit.
πŸ“ Dian Chairully said:
The Sick 1023546 CLV490 bar-code scanner in the shop isnt working.
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Contact Us

πŸš‘Shop LocationπŸ› οΈ

Industrial Electronic Repair