me podrian enviar el manual de usuario de:atlas copco compresor de aire estacionariosGA50VSD FFYA QUE HAY UN PROBLEMA EN LA PARTIDA PRODUCTO DE ESTO EL EQUIPO SE DETIENE Y EL ELEKTRONIKON ARROJA ERROR 177 .SE AGRADECERIA MUCHO SU AYUDA .SALUDA ATTE. A USTED VICTOR RIQUELME INGENIERO ELECTRICO .

—> Purchase or Repair: Ticket Image

— Posted by victor riquelmesaavedra on 2009-09-05

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
Estimates are free with an approved repair. Declined or unrepairable units are subject to a $75 evaluation, handling, and standard return-shipping fee. Extended warranties may be available.
Shipping/Receiving:
Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by Mario Canaza on 2012-04-12 19:31
por favor requiero con urgencia los documentos referidos al compresor GA160-10AP-380V/50Hz, tengo problemas con la salida de aire que entrega humo.

—> Purchase or Repair:
#Atlas Copco by Khaerudin on 2010-05-05 11:48
I have two units Screw Compressor Atlas copco GA 22.There is problem in the electrical.I need an wiring electrical for compressor Atlas Copco GA 22,please send me to wiring electrical.Best Regards,Khaerudin

—> Purchase or Repair:
#Atlas Copco by ngodactoan on 2009-12-25 09:19
I\'m Toan. I am working in MSP-1, White Tiger Field. We used Ga-75. Now, we don\'t have document \" manual of Electronikon\". You can hepl me, send for me document.

—> Purchase or Repair:
#Atlas Copco by Jack Mc Sweeney on 2015-08-02 21:20
I'm experiencing some issues with the Atlas Copco Elektronikon II 1900071012 compressor controller. It seems like something has stopped working properly. I'm not entirely sure what the model does, but I wanted to reach out for assistance with troubleshooting.

—> Purchase or Repair:
#Atlas Copco by Roopnarine Jaikishun on 2009-05-03 16:34
hi i am asking u if u could please send me a copy of the operation and trouble shooting manual for the GA75 compressor (100 Hp).thank you.

—> Purchase or Repair:
#Atlas Copco by Abadat ali on 2010-02-18 09:47
Dear we are using your compreesoors Model GA 55 FF & GA 30 FF.Pls send ud the prevetive maintenance schedule urgently. Thanks a lot.Abadat AliMaintenace Incharge.

—> Purchase or Repair:
#Atlas Copco by kasiyanto on 2013-01-29 03:33
Dear sir,I am kasiyanto.Here one problem in electronikon-iii(ZT-22) panel can not see display.can or not i change dispaly with ather type(ZT-45)Please replay imformation for me about that in my emailThanksBest regardskasiyantocikampekindonesia

—> Purchase or Repair:
#Atlas Copco by MAZOUARI on 2012-04-19 13:03
Bonjour;merci bien de m\'envoyer la documentation technique relatif au régulteur Electronikon PN:1900070125

—> Purchase or Repair:
#Atlas Copco by Russell Smith on 2013-10-27 22:34
I am needing all electrical schematic control diagrams

—> Purchase or Repair:
#Atlas Copco by Albayrak on 2015-07-20 07:20
The Atlas Copco Elektronikon II 1900071012 compressor controller is not working properly.

—> Purchase or Repair:
#Atlas Copco by Rumen Nanev on 2009-08-11 18:32
I need more information for Atlas Cotco GA55

—> Purchase or Repair:
#Atlas Copco by shainu.k.s on 2011-01-15 06:43
please send the electrical diagram of GA75

—> Purchase or Repair:
#Atlas Copco by Pankaj kumar gochhayat on 2015-06-09 05:54
Dear sir,Kindly provide us mentioned guide and parts manuals for maintenance the 3 nos of new compressor

—> Purchase or Repair:
#Atlas Copco by Gerry Oberst on 2011-05-18 15:24
Need manual in order to service the compressor properly.

—> Purchase or Repair:
#Atlas Copco by mourad on 2016-09-13 09:41
J\'ai deux compresseur atlas copco GA 75 FF + ET j\'ai besoin du schéma electrique pour COMPRESSEUR GA 75 FF+

—> Purchase or Repair:
#Atlas Copco by Changdev Markad on 2011-05-16 12:35
dear sir,we are facing a lading problem in our GA 45+ compressor .On the screen is showing the loading but actual presser is not develop , because 110 v/Ac supply is not getting to the load and unload solenoid coil.Pls sugest the possiblecause for the same and also send me the Electrical manual for …Purchase or Repair: Ticket Image...
Show More
Hello.I need your help. so i need the MANUAL of compressor atlas copco ga-55 I have 3 compressors and i don\'t have the manuals please send me information about this.thanks..

—> Purchase or Repair:
#Atlas Copco by M.V.Vinodan on 2008-10-02 07:35
Iam working in alico aluminium and light industries company.When I main power On; in the controller appearing 1003000000 this number.Our compressor not wrking .Pls give me the remedy.Serial nr. 0501700033Part nr. 1900 0701 05

—> Purchase or Repair:
#Atlas Copco by muhammad amin on 2015-08-09 05:20
The Atlas Copco Elektronikon II 1900071012 compressor controller is not working.

—> Purchase or Repair:
#Atlas Copco by moolchand on 2009-12-29 07:43
i want to know what point change when elktornikon control mode change local to remote

—> Purchase or Repair:
#Atlas Copco by Ionescu Lucian on 2008-05-18 06:20
I wont to repair atlas copco compresor

—> Purchase or Repair:
#Atlas Copco by Mohamed Younis on 2010-02-17 09:24
good morningI need manual book Electronikon II in pdf filethanksM. Younis

—> Purchase or Repair:
#Atlas Copco by ABDUL RAZZAQ on 2011-02-02 06:51
please send me manual for ga75 and ga 810 manual

—> Purchase or Repair:
#Atlas Copco by virenderm mudgil on 2011-05-04 13:43
pl give the solution for vsd 37 compressor fault - oxfa31.

—> Purchase or Repair:
#Atlas Copco by hamel on 2017-04-29 16:38
our company sonatrach ;we are facing a system failure 106 in our atlas copco zt 18 please give me a help to resolve this problem

—> Purchase or Repair:
#Atlas Copco by ramon palaca on 2011-12-05 08:14
Good day and peace to all...Dear Sir,Pleased to request a manual for atlas copco GA-55 model,we are currently doing PM on our machine andwe need to identify the parts to purchase. And we need to knowhow to dismantle the element/air end step-by-step.appreciate so much your help.thank you and god bles…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by salim on 2016-11-08 16:35
when i installed new controller we received on screen 110300000000please help me, controller shows fault 110300000000. I need your help to rectify the fault .

—> Purchase or Repair:
#Atlas Copco by eltahir on 2009-11-06 20:59
Atlas Copco failure with code 106

—> Purchase or Repair:
#Atlas Copco by Gianni on 2008-02-22 13:45
Very likely send temperature sensor failure

—> Purchase or Repair:
#Atlas Copco by Jill on 2012-09-21 01:49
We experienced unexpected downtime due to a malfunction with the Atlas Copco Elecktronikon 1900-0590-12 controller. This issue occurred during our shift earlier today. Can anyone provide insight or assistance before the next shift begins? Thank you.

—> Purchase or Repair:
#Atlas Copco by hazim on 2019-05-01 18:58
fault code 31 no retain

—> Purchase or Repair:
#Atlas Copco by ch rk vital on 2012-02-25 12:51
My Atlas Copco 1900-0700-08 is acting up. It seems like the controller has stopped working. Can you please help me troubleshoot the issue?

—> Purchase or Repair:
#Atlas Copco by Snead on 2008-08-25 16:18
Please help us determine if the Atlas Copco 1900 0701 02 Elektronikon unit is still supported or if replacement parts are available. Thank you.

—> Purchase or Repair:
#Atlas Copco by ahmed gomaa on 2012-03-14 09:46
manual for Elektronikon controllerfor ga15ff

—> Purchase or Repair:
#Atlas Copco by vikas borana on 2016-11-21 08:30
GA 30 COMPRESSURE ELECTRICA DIAGRAM

—> Purchase or Repair:
#Atlas Copco by Piyush rajgor on 2016-11-04 06:01
Sir pls inform me what is the mean of this alarm (100300000000) and how to remove thisThanking you

—> Purchase or Repair:
#Atlas Copco by PESEK on 2012-02-04 10:25
Hello, I'm reaching out on behalf of a client who is experiencing issues with an Atlas Copco 1900-0700-08 controller. Can you please provide information on repair options and estimated costs? Thank you.

—> Purchase or Repair:
#Atlas Copco by Wallace on 2015-07-24 19:20
The Atlas Copco Elektronikon II 1900071012 compressor controller is malfunctioning, leading to a halt in production. Urgent repair service is needed to restore operations

—> Purchase or Repair:
#Atlas Copco by MUHAMMAD JAMIL AKHTER on 2010-07-09 14:58
COULD U PLEASE SEND ELECTRIC DIAGRAM OF GA75 ATLAS COPCO AIR COMPRESSOR FOR REPAIRING AND MAINTENANCE

—> Purchase or Repair:
#Atlas Copco by abdesslam kebir on 2017-11-08 06:17
we have a problem with elektronikon II . it does not show anything so we need the wiring diagram to locate the default

—> Purchase or Repair:
#Atlas Copco by cheikh on 2012-05-07 10:50
Compresseur Atlas est trés utilisé au sénégal

—> Purchase or Repair:
#Atlas Copco by David on 2009-08-03 11:40
Very interesting and really needed manual

—> Purchase or Repair:
#Atlas Copco by khalid on 2011-11-26 11:26
Bonjour, Je suis un agent technique travaillant à RADEEF FES MAROC et j\'ai un problème sur le compresseur Atlas Copco GA18: le module Electronikon m\'affiche : défaut système code erreur 200 et je n’arrive pas à résoudre le problème.Je viens vous demander de bien vouloir m\'orienter à trouver la so…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Florentino Lagumbay on 2006-08-18 03:08
My client need this replacement part 2pcsAtlascopco Elektonikon, PN 1900 0701 23control type, 24 VACPls email quotation to : porkydouglas@yahoo.com

—> Purchase or Repair:
#Atlas Copco by Leiron Atienza on 2010-06-12 15:50
Good day gents!May we have a copy of the Elektronikon controller manual. Also the manual of the Elektronikon Input Module, we are having issues with the input from the dewpoint sensor.Many thanks....

—> Purchase or Repair:
#Atlas Copco by Orman on 2013-08-11 10:35
The Elektronikon 1900 0701 05 Controller went down mid-shift, needs attention ASAP. Night shift maintenance crew.

—> Purchase or Repair:
#Atlas Copco by Anil shinde on 2010-09-15 07:35
All programmes are well explained and good for reference.

—> Purchase or Repair:
#Atlas Copco by IONESCU on 2013-08-05 07:32
It sounds urgent. If you require immediate assistance, please let me know.

—> Purchase or Repair:
#Atlas Copco by anupam on 2009-12-23 07:00
It\'s a very good compressor ,reliable and suitable for our requirement.

—> Purchase or Repair:
#Atlas Copco by NIKHIL DOSHI on 2012-05-26 05:25
Dear Sir,Pleased to request a manual for atlas copco GA-55 model,we are currently doing PM on our machine andwe need to identify the parts to purchase. And we need to knowhow to dismantle the element/air end step-by-step.THANKSNIKHIL DOSHIRAJURI STEEL PVT LTD JALNA

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.