dear sir:i need wiring schematic for atlascopco ga11-22 atr comperessor.thanks.

—> Purchase or Repair: Ticket Image

— Posted by reza on 2009-12-16

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by hadi on 2009-11-02 02:53
hello,dear! my company have two compressor model ga55 ff. and this compressors is good product. But I have problem abaut \" dp oil separator\". It problem is pressure to high. To high from maximum servise [ 1 bar ].Please, can you help for this problem?

—> Purchase or Repair:
#Atlas Copco by Hassan on 2009-05-11 12:14
Dear Sir,I have Atlas Copco : Compressor GA30 VSDInverter Siemens : 6SE7027-2ED61-ZController Atlas Copco: 1900 0701 82Compressor Controller Atlas Copco:1900 0701 06I had problem in inverter, the Siemens maintenance was solved it.My problem is: How to set communication panel with control? And data f…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Deon Govender on 2010-08-09 05:38
Good morning, I tried to download your user manual and troubleshooting guide for my Atlas Copco GA 90 Elektronica II compressor. Please send me all the relevant manuals for these compressors. Thank you Deon Govender

—> Purchase or Repair:
#Atlas Copco by hany sobhy on 2008-01-21 05:34
want know elektronikon ll data sheet and trouble shooting becuse we have this type in our plant power station in aser power station in sodi arabia please sent the files at my email adress and many thx

—> Purchase or Repair:
#Atlas Copco by mukasakuraish on 2010-08-09 12:32
Good working machines

—> Purchase or Repair:
#Atlas Copco by amusa olatunde on 2012-09-19 17:15
Electrical drawing for ga75w compressor

—> Purchase or Repair:
#Atlas Copco by Hoa Nguyen on 2011-01-16 09:19
Please, i need manual atlas copco GA55FF,GA75, GA100Thank you.

—> Purchase or Repair:
#Atlas Copco by Richard donovan on 2012-02-15 09:43
Our Atlas Copco 1900-0700-08 unit is still down. Please respond

—> Purchase or Repair:
#Atlas Copco by kevin schofield on 2014-12-10 21:24
Please send the operation manual for the ElektroniconII on our 2006 compressor. type GA11VSDNr AP1160620I am in need of the manual for the Elektronikon II only.Thank you,kevi schofield

—> Purchase or Repair:
#Atlas Copco by Clint Turoldo on 2011-10-05 21:05
Hi there, our Atlas Copco Elektronikon II controller has stopped working, and we can't seem to find a replacement. Can you provide repair information or recommend a repair shop? We need a quick solution. Thanks!

—> Purchase or Repair:
#Atlas Copco by Dhan Chavez` on 2021-07-30 02:43
sensor error appeared on screen..what to do?

—> Purchase or Repair:
#Atlas Copco by maintenance on 2009-02-02 14:22
manuel elktronikon pour ga45 atlas copcocomment cabler une commande externe

—> Purchase or Repair:
#Atlas Copco by Inderjit Singh Rana on 2012-03-06 13:20
Dear Sir/madamI have purchased used compressor for trader. I request to send complete manual for our reference.RegardsI S Rana

—> Purchase or Repair:
#Atlas Copco by ARAVIND V on 2009-12-01 09:46
we have an air compressor\"ATLAS COPCO GA-30 \"that has served us around 6 years ,today that stoped working & shows an error code\"system failure 104\".SO am waiting for your valiable responds to solve this. Thanking you Aravind

—> Purchase or Repair:
#Atlas Copco by jonas hofer on 2011-04-16 19:39
Our Atlas Copco Electronikon 1900-0701-04 is still not working. We require immediate assistance and a response. Kindly address this issue

—> Purchase or Repair:
#Atlas Copco by Senthil Kumar P on 2015-03-29 21:49
The Atlas Copco Elektronikon II 1900071012 compressor controller is displaying abnormal behavior in the warehouse.

—> Purchase or Repair:
#Atlas Copco by Khaerudin on 2010-05-05 11:48
I have two units Screw Compressor Atlas copco GA 22.There is problem in the electrical.I need an wiring electrical for compressor Atlas Copco GA 22,please send me to wiring electrical.Best Regards,Khaerudin

—> Purchase or Repair:
#Atlas Copco by bishelnoor on 2012-03-20 07:48
very good comprossor and it very easy to serves and operate .little faulte and give enough pressure.

—> Purchase or Repair:
#Atlas Copco by Sergio Tusen on 2011-04-28 15:21
Buenas Necesito conseguir el manual de uso de el Display Elektronikon para un compresor de Tornillo mod. GA55.

—> Purchase or Repair:
#Atlas Copco by Todd Ruesch on 2010-03-22 01:59
Hi there, we have an issue with our Atlas Copco Elektronikon 1900070124 controller and need a replacement. Could you please provide repair information or let us know where we can find a replacement quickly? Thank you!

—> Purchase or Repair:
#Atlas Copco by Matheus Rodegheri on 2012-01-03 13:24
Hello,We need the repair manual of this compressor to make the maintenance. Can you send to me?Regards

—> Purchase or Repair:
#Atlas Copco by zahid iqbal on 2014-03-03 06:49
dear sir ihave ga 55 kw air comprosser want ELECTRICAL DIAGRAM part no 1900.0590.73 and searil no 93023934 supply voltage24volts ac pls u give me electrical diagram thanks sir

—> Purchase or Repair:
#Atlas Copco by paul busenbark on 2010-09-27 11:58
Retrofit install on a GA 75. Need a manual for the Elektronikon II. When retrofit installed we did no get a manual. We need to reset the maintenance required on unit to disable the red warning light since serviced.Thank you!

—> Purchase or Repair:
#Atlas Copco by Muhammad Murtaza on 2011-11-20 14:22
Required manuel elektronikon controller

—> Purchase or Repair:
#Atlas Copco by VIJAY.M on 2011-09-30 11:30
WE ARE VERY HAPPY WITH PRECISE PERFORMANCE WITH GA18+ MODEL

—> Purchase or Repair:
#Atlas Copco by Gabriel Gonzalez Ramirez on 2012-01-23 17:36
Hello, I am inquiring about an Atlas Copco controller with the part number 1900-0700-08 that needs repair. Can you provide information on the services and costs involved? Thank you.

—> Purchase or Repair:
#Atlas Copco by harish nyati on 2012-05-24 02:56
Sir,We have procured one item from you and it,s name as per your sticker affix on item is \"spacer part no 1622340000\"Please let me know that Element oil_seperator part no 162234000 of ga55awp is same as given above spacer.

—> Purchase or Repair:
#Atlas Copco by saeod on 2011-05-14 19:59
for univercity

—> Purchase or Repair:
#Atlas Copco by Victor on 2010-02-17 07:07
Dear sir ,need Elektronikon I panel manual.We are use Your product (air compressor) With best regardsVictor

—> Purchase or Repair:
#Atlas Copco by GENENE ALEMU on 2016-11-07 08:35
Atlas copco product is /are a world wide known product. currently we need electrical diagram of this machine.

—> Purchase or Repair:
#Atlas Copco by Giar Ronald on 2009-09-06 00:15
We want to buy Elektronic RegulatorParts No. 1900 0701 24For Atlas Copco GA 160 Compressor

—> Purchase or Repair:
#Atlas Copco by asd on 2009-03-27 14:09
hello ...i need prouser to commnecation between atlas copco..comproser and pc .thank you

—> Purchase or Repair:
#Atlas Copco by Martín German on 2013-01-29 20:43
Hello,I need the manual of air compressor Atlas Copco brand model: GA55FFThank youMartín Germán

—> Purchase or Repair:
#Atlas Copco by joseph ugwuneke on 2014-10-15 17:46
please I want the complete electrical schematic drawing for your compressor XAS 185 JD, as I have a group of these compressors and now having problem with one, it shuts down after five munities of starting it up. please be of help to me, I am still recommending atlas copco as a very good product, Pl…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by De Veirman Willy on 2010-10-07 09:04
Hello,I have one older type of compressor in my factory, but i missing the manual.Is it possible to send my that.The type is;GA22 Serial AII 261 662 2001Best regards,Willy

—> Purchase or Repair:
#Atlas Copco by chagas on 2009-06-02 00:30
por favor gostaria que se possivel me enviassem manual de algumas maquinas (compressores) obrigado

—> Purchase or Repair:
#Atlas Copco by Engr. Muzaffar on 2020-09-26 07:52
Error code 7301 System failure GA90VSD with 7301 defaultPlease suggest solution of this error as soon as possible.Thank you.

—> Purchase or Repair:
#Atlas Copco by moradi on 2014-12-29 07:52
hi dear we need to terminal detail for elektronikon ll for use the drive for our compressor

—> Purchase or Repair:
#Atlas Copco by souhad Zebian on 2009-07-18 10:03
Dear Sir,we are facing problem getting the right support from the local AC personnel as always these docuemnts are protected .please we urgently requesting the following documentation:1- trouble shuting manual for ZR 250 2- ES8 and electronikon software and control logic.your support in this matter …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by collins kawanga on 2008-11-25 08:38
may you send me the operating/user manual for ELEKTRONIKON FOR GA 250 FF

—> Purchase or Repair:
#Atlas Copco by JOHNNY MARTINEZ on 2014-11-21 05:12
Hello I\'m johnny from mexico, I have a little problem whit a machine atlas copco GA75 FF , In the display of Elektronikon , appear a error , the number is 100300000000 . thhank so much for you help beste regards

—> Purchase or Repair:
#Atlas Copco by amin on 2018-12-05 07:58
1900 0701 05 display error 1003000000001900 0701 03 display error 100200000000plaese help me

—> Purchase or Repair:
#Atlas Copco by Francisco Partida on 2011-10-11 15:04
To whom it may concern, I have a problem wiht an Atlas copco compressor. It apears a message:System Failure 200The compresor does\'t start and it seems it is in mannual opperation. Do you know what happens?Regards Francisco Partida Molina

—> Purchase or Repair:
#Atlas Copco by Tracey Norouziani on 2012-12-03 05:48
Hi I was wondering if possible if you have the electrical diagram for the ga 45 atlas copco. I\'m getting a error saying \"run phase sequence\" Can you PLEASE HELP? if you have the diagram would you please send me a copy.Thank You Tracey

—> Purchase or Repair:
#Atlas Copco by rajesh on 2017-04-12 06:55
good morning,i have a problem in electronikon iv controller , shut down reset is not done. message is Starter contact feed back is closed. but feed back is healthy. and LOCAL Control B is showing instead of LOcal Control A. I Need trouble shooting service manual

—> Purchase or Repair:
#Atlas Copco by KARIM NAJEM on 2011-05-05 12:56
DEARKINDLY CAN YOU SUPPY ME GA7 MAINTENANCE MANUAL. I AM WAITING YOUR REPLAY.BEST REGARDSKARIM

—> Purchase or Repair:
#Atlas Copco by Anirudh Parida on 2013-06-01 05:26
Dear Sir,We are facing problem in Klektronikon II Regulator as follows :Warning Massage : System Failure 104.In the manual Code 104 is not mentioned. Pl. confirm us the possibility area of problem.Note : This is used for Atlas Cope Air Compressore.Regards,Anirudh Parida, Sr. Manager Elect.For PSL Lt…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Mamo Boykie on 2008-09-02 10:53
Got stationery comprssor from Atlas Copco SA

—> Purchase or Repair:
I NEED OPERATION & MAINTENANCE MANUAL OF Atlas Copco GA7 FF, ALSO I NEED TO KNOW HOW MANY OPERATING HOURS I NEED TO CHANGE Oil filter & oil separator, I HAVE NOT ANY MANUAL FOR AIR COMPRESSOR, thank you so much

—> Purchase or Repair:
#Atlas Copco by tamer on 2012-03-18 08:13
electrical connect of atlas copco elektronikon 1900 0701 04 ,ga50 vsd

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.