Hey there, we're in need of a replacement for an Atlas Copco Elektronikon II 1900071012 Compressor Controller. Unfortunately, we couldn't find one. Can you provide us with repair information or let us know where we can source this part ASAP? Thanks!

—> Purchase or Repair: Ticket Image

— Posted by Charles Rachlis on 2015-07-23

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by bayo on 2010-02-11 10:27
please i cant start my atlas copco GA 75, it show system failure 10, 00100000.what can i do

—> Purchase or Repair:
#Atlas Copco by ali on 2009-06-18 13:03
I the manual for the Electronikon type number 1900 0700 05

—> Purchase or Repair:
#Atlas Copco by omar on 2016-12-08 18:36
at work some of our electrical tech put 110v for input 24v that cause problem where compressor controLler is off i found SMD input Resistance is damage i change smd where controller is work without data what i do, also i need wiring digram for compressor where compressor data is:ATLAS COPCOpart no: …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by samir on 2010-11-03 14:30
atlas copco meilleur constructeur

—> Purchase or Repair:
#Atlas Copco by benmerkhi on 2011-02-11 06:48
Please send us the regulator electric wiring diabgram of GA75.Kind regards

—> Purchase or Repair:
#Atlas Copco by Goran on 2010-09-09 11:14
pls send electrical wiring diagram of atlas copco gx 11 ff

—> Purchase or Repair:
#Atlas Copco by Zamir on 2014-10-10 05:43
Hi,I am Maintenance engineer I need the detail of \" System Failure 10\" of Atlas Copco 75KW compressor. Can you help me in this matter? Also if you have its troubleshooting manual then please send it me on above email id. ThanksRegards,ZamirMechatronics & Control Engineer

—> Purchase or Repair:
#Atlas Copco by sarwar alam on 2008-04-22 05:31
we are using in our plant and founnd good duty comp. but some times its coming compressor off while after un louding programe & motor should stopped only .

—> Purchase or Repair:
#Atlas Copco by janusz on 2009-02-16 11:53
We have 2 compressores (manufactured by Atlas Copco) with model of engine XAS 175 and XAS 175N. This compressores are about 10 years. Where I can find user manual?

—> Purchase or Repair:
#Atlas Copco by bayu pratamap on 2011-09-20 01:26
dear,May you give us some informations about manual operation and connection from elektronikon II for our part elektronikon II.Thank you

—> Purchase or Repair:
#Atlas Copco by dehner on 2013-08-03 23:32
The Atlas Copco Elektronikon 1900 0701 05 is not working. Please check and troubleshoot as needed.

—> Purchase or Repair:
#Atlas Copco by Korzhenevskii SerG on 2008-02-01 09:52
Hi, i have a problem with a compressor Atlas Copco ZR 145. I require documentation Electronikon øò order to determine a problem of a soaking up step and the engine of the compressor.

—> Purchase or Repair:
#Atlas Copco by ADESINA AGBOOLA BAYONLE on 2007-06-11 19:55
BEST USED PRODUCT IN NIGERIA MARKET

—> Purchase or Repair:
#Atlas Copco by K. Nageswara Rao on 2011-10-28 10:51
Technical specifications for GA7FF Atlas Capco Air compressor please

—> Purchase or Repair:
#Atlas Copco by jorge de leon on 2009-10-28 16:01
we have a atlas copco compresor model GA90USD SERIAL NUMBER A11495509 could you send me be email the manual please.

—> Purchase or Repair:
#Atlas Copco by mohammad dadkhah on 2015-02-02 10:39
helloi want the electrical wiring of ga75 i dont know the wiring between the sockets 2x1 ,2x2,...2x9 of elektronikon control board.

—> Purchase or Repair:
In our plant, we have 2 nos GA 22+ compressors installed & in service for about 4 years. We would like to have Part manual & service manual with exploded drawings for use & reference.

—> Purchase or Repair:
#Atlas Copco by Faizal Khan on 2019-04-13 03:24
I have Atlas Copco GAe30 P A 8.5,WUX251745,4.5,30,8.3 KW,year 2011-04.bought from Gamma Gas,China.Due to power shut the compressor can not restart,looks like password erased,we tried every way to restart,while selecting icons password shows blank.On screen number shows 00 bar despite going on 8.5 ba…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by anupam on 2009-12-23 07:00
It\'s a very good compressor ,reliable and suitable for our requirement.

—> Purchase or Repair:
#Atlas Copco by Riccio on 2012-06-28 07:01
The Atlas Copco 1900-0700-08 controller unit malfunctioned today during the morning shift, causing unexpected downtime. Please investigate and provide a quick answer before the next shift begins. Thank you.

—> Purchase or Repair:
#Atlas Copco by lotfi on 2012-04-14 17:33
The Atlas Copco 1900-0700-08 controller is not working.

—> Purchase or Repair:
#Atlas Copco by Ramiro García on 2009-09-22 18:34
Please, i need manual atlas copco GA 75Thank you.

—> Purchase or Repair:
#Atlas Copco by Ankur Patel on 2012-01-22 06:23
We having a 11nos. of ZHC-7000 compressors,we are planing to take all compressors reading in DCS for that we procure Combox-S but we can\'t having a modbus address for compressor parameters so kindly help for that. Please sent me modbus address on my mail

—> Purchase or Repair:
#Atlas Copco by Nathan Yehirai on 2016-06-24 21:11
Hello,We are having issues with a GA30+ compressor. The controller is not accessible. It has a fault code that is locking out the controller and causing the not to start . The display on the controller is indicating B -SW 0106. Please can you assist by sending me a Troubleshooting/Service Manual and…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by DAMBO WALSON on 2009-01-07 16:58
SIR.THE ELECTRONIKON ON OUR GR-132 COMPRESSOR DOES NOT RESPOND TO COMMANDS. PRESSIND THE FUNCTION KEYS , NO RESPONSE COMES ON. ALL WE SEE IS THE GENERAL ALARM THAT IS PERMANENTLY ON . EVEN WHEN THE FIELD DEVICES WERE DISCONNECTED THE ALARM REMAINED AND SUCH NOTING FOR NOW COULD BE DONE. WE NEED A TE…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Mario Machado on 2008-06-02 21:56
Dear Sr.I Need ELECTRONIKON technical Manual..P/N: 1900 0700 08 ed: 01serial: 02024700083Mário

—> Purchase or Repair:
#Atlas Copco by marlon mejala on 2017-08-22 10:27
need to troubleshoot overload error of compressor

—> Purchase or Repair:
#Atlas Copco by ed lopez on 2009-08-10 22:31
hello, i need the user manual for conection of two compressor , one first and other auxiliary, thanks.

—> Purchase or Repair:
#Atlas Copco by barhoumi on 2011-05-26 20:55
le meilleur marque international

—> Purchase or Repair:
#Atlas Copco by waleed ALKHATEEB on 2010-04-30 12:14
DEAR SIR I am working in JORDAN PHOSPHATE COMPANY JPMC We used GA-90.compressor year of manuf. in 2001 Now, we have a problem on the Elektronikon Control Module we have massage error 104 system fault we don\'t have document \" manual of Electronikon\". You can hepl me, send for me document.and help …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by neili lotfi on 2012-12-24 08:24
what mean the \"110300000000\" alarm please.Faithfully

—> Purchase or Repair:
#Atlas Copco by karbou on 2009-11-04 18:02
i have a atlas copco GA 55 with a old elekctronikon, i need de program it best regard

—> Purchase or Repair:
#Atlas Copco by Fred Santizo on 2012-04-22 07:44
Please provide an urgent update on the repair status of the Atlas Copco Elecktronikon 1900-0590-12 controller. The unit is still down and we need immediate assistance.

—> Purchase or Repair:
#Atlas Copco by Kyle Weeks on 2011-06-14 16:19
Can the Atlas Copco Electronikon 1900-0701-04 Display Unit be repaired or replaced? I'm trying to check this off my to-do list. Thank you!

—> Purchase or Repair:
#Atlas Copco by J Mitchell on 2013-05-09 20:37
Originally had to send the simovert drive for repair due toit faulting on f11 and f26. The repair company told there had replaced 2 faulty items carried out a function test. all ok. They then returned the drive which I subsequently refitted and powered the compressor up and tried to start it only ge…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Nelson Molina T. on 2008-02-14 16:19
Dear Sr.I Need ELECTRONIKON II technical Manual..Nelson Molina T.BIOFILM S.ATel. 575 6685456Fax. 575 6685473Cartagena -Colombia

—> Purchase or Repair:
#Atlas Copco by Matheus Rodegheri on 2012-01-03 13:24
Hello,We need the repair manual of this compressor to make the maintenance. Can you send to me?Regards

—> Purchase or Repair:
#Atlas Copco by rahimi on 2010-04-01 19:58
Dear Sir,we need maintenance manual of GA75 Air Compressor(Oil inject compressor).please send us of it.we are waiting for your reply.regards.rahimi

—> Purchase or Repair:
#Atlas Copco by Ensummaupsend on 2007-09-19 09:52
Could you please provide more details on the Atlas Copco Elektronikon Mark IV 1900 0710 31 unit so that I can check if it is still supported and if replacement parts are available? Thank you.

—> Purchase or Repair:
Hello.I need your help. so i need the MANUAL of compressor atlas copco ga-55 I have 3 compressors and i don\'t have the manuals please send me information about this.thanks..

—> Purchase or Repair:
#Atlas Copco by abdulwaheedftc@live.com on 2012-06-22 17:53
plz give me reparng manual for Electronikon II controller GA 55+

—> Purchase or Repair:
#Atlas Copco by PANKAJ on 2014-08-20 12:22
Dear , sir I have used ZR-250 comp. in moserbaer india limited. So alarm comes on -110300000000 . so please clear this alarm . what is alarm reason . urentlyReg.Pankaj

—> Purchase or Repair:
#Atlas Copco by paimblanc on 2013-05-08 06:27
The controller on my Atlas Copco GA45 1900.0590.74 industrial unit is not functioning properly and needs repair. Looking for assistance to get it back up and running efficiently as soon as possible. Thank you.

—> Purchase or Repair:
#Atlas Copco by Carlos Franchin on 2009-09-16 14:09
I can\'t start my GA75. When i power up, the Elektronikon II, show: time out inversor.What is this?What should I do?Please send to me: Manual Elektronikon II.too ,Thank you!!!

—> Purchase or Repair:
#Atlas Copco by mehdaoui on 2010-08-15 04:36
Bonjour, Je suis un instrumentiste travaillant à In Salah GAs (Sonatrach/BP) et j\'ai un problème sur le compresseur Atlas Copco: le module Electronikon m\'affiche : défaut système code erreur 106 et je n’arrive pas à résoudre le problème. Je viens vous demander de bien vouloir m\'orienter à trouver…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by BALAJI on 2010-07-24 05:22
we have 4 atlas copco ga55 our in our site and we need compressor and compressor controller user manual and if it possible the controller schematic diagramthanks with the best regards

—> Purchase or Repair:
#Atlas Copco by Cristian David Bendik on 2008-08-27 12:57
Can you send me a electronikon manual in pdf file?, i have a problem with a compressor GA90-160, This starts without reaching the value of cargo .ReggardsCristian

—> Purchase or Repair:
#Atlas Copco by Nikesh Raut on 2011-05-02 04:55
I need an electrical Drawing of Atlas Copco make Compressor model GA 160 .Kindly arrange as soon as possible

—> Purchase or Repair:
#Atlas Copco by Daniel Goarnisson on 2011-08-28 11:02
Please, can you send me the spare parts and maintenance manuals for compressors Atlas copco Type GA 75 P, S/N AP1610227 to 229. Thanks and best regardsDaniel

—> Purchase or Repair:
#Atlas Copco by mngwenya on 2012-07-29 16:52
which port on the regulator is reserved for CAN connection to the COMBOX-P?

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.