#Atlas Copco by mohamed kandil on 2011-10-24 08:16
i have ZR-250 compressori have worning condensate drain RC out not ok and zr-160 compressorelement frist tempr maximum 227 cmax = 225

—> Purchase or Repair:
#Atlas Copco by Daniel Clifton on 2009-09-15 16:45
excellent company

—> Purchase or Repair:
#Atlas Copco by azadeh on 2009-04-20 11:37
plise sent to me catalog for circuit of electronikion to my email.tanks for you .

—> Purchase or Repair:
#Atlas Copco by ThanhDat on 2011-04-03 07:38
Dear service Manager!We are using Atlas Copco Compressor GA 15, A MESSAGE IS APPEARING IN LCD THAT \"SYSTEM FAILURE 200\"PLS TELL ME THAT HOW I CAN REMOVE THIS ERROR ,PLS REPLY ME URGENTLY.THANKS

—> Purchase or Repair:
#Atlas Copco by Piotr on 2011-05-10 15:54
Good day,I\'m chief engineer on the vessel and I have new Atlas Copco compressor on board, type GAP26P whit graphical display. Because I use this copressor for control air, I would like to activate the automatic restart function. Unfortunately there is some password. Can I recive this password by e-…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Abadat ali on 2010-02-18 09:47
Dear we are using your compreesoors Model GA 55 FF & GA 30 FF.Pls send ud the prevetive maintenance schedule urgently. Thanks a lot.Abadat AliMaintenace Incharge.

—> Purchase or Repair:
#Atlas Copco by Azhar on 2008-07-14 07:45
Can i get manual for Atlas Copco GA37

—> Purchase or Repair:
#Atlas Copco by musa batari on 2008-06-02 16:28
we have twoof this type of compressor in my section for bag filters, resently we had a problem of the display unit went off completly. we try to trace the problem but is difficult becouse the circuit diagram was too tiny to read. pls. can you send a pdf copy to me so that it will help to trace any p…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by marlon mejala on 2017-08-22 10:27
need to troubleshoot overload error of compressor

—> Purchase or Repair:
#Atlas Copco by Yalember Setotaw on 2017-01-24 07:07
Best Brand i ever see

—> Purchase or Repair:
#Atlas Copco by BIL07 on 2012-01-09 10:01
MESSAGE IS 100300000000 CAN HELP ME IN ES100 MK3

—> Purchase or Repair:
#Atlas Copco by derrick mwape on 2008-11-18 23:50
Send me user manual for the above control and protection unit which also has fault diagnostics.

—> Purchase or Repair:
#Atlas Copco by farid sumawan on 2011-01-20 02:59
Dear SirAtlas Copco has to work optimally with minimal maintenance costs. Reliability has been proven in operation since 1998. only now there are problems in controll system, and I need a manual for solving problemsThank\'s for your kind attention and look forwardregardsfarid sumawan—> …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by p.srinivasu on 2008-06-30 14:51
power off with out any triping

—> Purchase or Repair:
#Atlas Copco by HAMAMI DJAMEL on 2013-04-28 12:18
MANUEL OF GA22FFand problem, Element output hot air

—> Purchase or Repair:
#Atlas Copco by joe reese on 2012-11-26 12:18
Hi ,We have a atlas copco type GA7FF Product# 8153005742Ser#CAI 707465 the manual we currently have does not have correct display listed for troubleshooting. hope you can help Thanks Joe NCI Frederick MD

—> Purchase or Repair:
#Atlas Copco by FCO. VILLELA on 2008-01-30 21:41
Hi,i have some problems whit the mastercontrol elektronikon i want to say if you can to send my the users manual

—> Purchase or Repair:
#Atlas Copco by amusa olatunde on 2012-09-19 17:15
Electrical drawing for ga75w compressor

—> Purchase or Repair:
#Atlas Copco by Moty on 2012-02-28 19:08
My client is having issues with their Atlas Copco Elecktronikon 1900-0590-12 controller. Can you provide information on troubleshooting or repair options for this part number? Thank you.

—> Purchase or Repair:
#Atlas Copco by DAMBO WALSON on 2009-01-07 16:58
SIR.THE ELECTRONIKON ON OUR GR-132 COMPRESSOR DOES NOT RESPOND TO COMMANDS. PRESSIND THE FUNCTION KEYS , NO RESPONSE COMES ON. ALL WE SEE IS THE GENERAL ALARM THAT IS PERMANENTLY ON . EVEN WHEN THE FIELD DEVICES WERE DISCONNECTED THE ALARM REMAINED AND SUCH NOTING FOR NOW COULD BE DONE. WE NEED A TE…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Nasir Shamdar on 2022-03-29 09:22
I need some information regarding atlas copco dryer unit

—> Purchase or Repair:
#Atlas Copco by thomas nardini on 2008-04-21 21:14
The Atlas Copco 1900 0701 02 Elektronikon unit went down mid-shift. Need to troubleshoot and fix it ASAP.

—> Purchase or Repair:
#Atlas Copco by basim onnab on 2010-11-15 10:13
i have compressor controller of elektronikon 1900 0700 08 and i need the procedure to program this type of controllersso pls if you can send me by email service manualthank youe.basim onnab

—> Purchase or Repair:
#Atlas Copco by Syaiful Bachri on 2011-04-20 08:47
I have two Compressor Atlas Copco GA.37, and operation 1998 until now.I think series GA.37 very good. I need Manual Book & Part list because my book lose, so i need you for that.

—> Purchase or Repair:
#Atlas Copco by hadi on 2009-11-02 02:53
hello,dear! my company have two compressor model ga55 ff. and this compressors is good product. But I have problem abaut \" dp oil separator\". It problem is pressure to high. To high from maximum servise [ 1 bar ].Please, can you help for this problem?

—> Purchase or Repair:
#Atlas Copco by Satish Rane on 2009-09-03 05:58
I wanted to activate auto restarting for Atlas Copco after power resumption.To do this I required the above mentioned Manual

—> Purchase or Repair:
#Atlas Copco by Gerry Loftus on 2012-01-05 19:11
Dear Sir/MadamWould you have a Parts Manual for an Atlas Copco XAS 175 Compressor road compressor & What price?Thank you,Gerry Loftus

—> Purchase or Repair:
#Atlas Copco by Emiljan Laze on 2010-07-13 15:05
I need to have a copy for an air compressor Of ATLAS COPCO model GA160F.The owner of the compressor doesn\'t have that,Can someone help !!!

—> Purchase or Repair:
#Atlas Copco by aamir on 2008-11-08 05:33
I'm having some trouble with the Atlas Copco 1900 0701 02 Elektronikon. It seems like something has stopped working, but I'm not sure what exactly. Any assistance would be greatly appreciated.

—> Purchase or Repair:
#Atlas Copco by Bala on 2016-12-24 16:31
Hi,How to reset Elektronikon password to enable "modify parameters" load and unload setting.

—> Purchase or Repair:
#Atlas Copco by Lucio Roman on 2010-11-06 12:05
GA 160-10A

—> Purchase or Repair:
#Atlas Copco by DKIOUAK on 2012-08-01 21:55
The Atlas Copco Elecktronikon 1900-0590-12 controller on a unit went down mid-shift. Please check and troubleshoot the issue during the day shift. Thank you.

—> Purchase or Repair:
#Atlas Copco by Nazir Ahmad on 2010-04-09 13:45
I need the maintenance manual containing procedure of overhauling.

—> Purchase or Repair:
#Atlas Copco by DIMITRIS ZAOURIS on 2008-05-08 09:05
Dear sirWe are a food industry in Greece and we have two ATLAS COPCO GA115air compressors and i have a problem with the keyboard of the one unit.The electronikon screen works but when i want to change parameters the push buttons not work.I think that i need only the front keyboard.Can you provide th…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by khalid on 2011-11-26 11:26
Bonjour, Je suis un agent technique travaillant à RADEEF FES MAROC et j\'ai un problème sur le compresseur Atlas Copco GA18: le module Electronikon m\'affiche : défaut système code erreur 200 et je n’arrive pas à résoudre le problème.Je viens vous demander de bien vouloir m\'orienter à trouver la so…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Nicos Hadjisofokli on 2008-01-24 17:48
We have not received a response regarding the Atlas Copco 1900 0701 02 Elektronikon issue. It's essential that this matter is addressed

—> Purchase or Repair:
#Atlas Copco by collins kawanga on 2008-11-25 08:38
may you send me the operating/user manual for ELEKTRONIKON FOR GA 250 FF

—> Purchase or Repair:
#Atlas Copco by srinivas on 2011-02-28 04:40
Dear sir,Please help me out of this issue i am unable to trace out this problem in your Electrical diagram, Hence i request you to send me Electrical diagram of GA 55 compressor.thanks & regards,J Srinivas jammulasrinivass@gmail.com9440867602

—> Purchase or Repair:
#Atlas Copco by Randy Deel on 2011-05-23 20:16
I would like to have an error code list for the DM45.ex. 157FMI18

—> Purchase or Repair:
#Atlas Copco by sandeep on 2010-12-22 12:34
Sir,Madam,I have GA-75 model atlas copco make air compressor and it have electronikon make controller which are having problem , and it have showing only number on its display and this number is 100300000000 this nuber is blinking on this screen contineously so pl advice me how i can come to orignal…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by v.saravanan on 2013-12-24 09:23
sir, we want the electrical drawing for GA37KW VFD COMPRESSOR , so u pls send the drawing is earliear,

—> Purchase or Repair:
#Atlas Copco by Ngan Do Thuy on 2010-02-22 07:17
Dear Alats Copco!If you have GA 200 Compressor User manual, please send me. Thanks a lots

—> Purchase or Repair:
#Atlas Copco by MIR JAHANGIR on 2013-02-07 10:18
Dear Sir/Madam ;we have GA7 Compressors. We need this units\' documents as soon as possible. Please send me GA7 Compressors\' Operation and Maintenance Manuals & Spare Parts ListWaiting for your reply as soon as possible

—> Purchase or Repair:
#Atlas Copco by Engineer Akram Sadiq on 2008-09-13 19:52
i have a large measurement offset in the reading of the delivery air pressure transducer . can I Adjust it ?? . I can not see any screw or way to adjust this offset in the transducer .

—> Purchase or Repair:
#Atlas Copco by Deon Govender on 2010-08-09 05:38
Good morning, I tried to download your user manual and troubleshooting guide for my Atlas Copco GA 90 Elektronica II compressor. Please send me all the relevant manuals for these compressors. Thank you Deon Govender

—> Purchase or Repair:
#Atlas Copco by anwar on 2021-10-16 10:39
i have compressor controller ELEKTRONIKON 1900 SERIES ITS display showing code only 110300000000please let me know what is this and please send how to solve problemthanks

—> Purchase or Repair:
#Atlas Copco by THAMER POLINTAN on 2009-02-11 12:46
dear freindi have an air compressure model GA55 +9.1 bar during sumer the ambeant tempreture will be 46C and am geting always the out let tempreture between 90 to 115C so please let me know is this safe for my machine or i shall do some thingthanksregards

—> Purchase or Repair:
#Atlas Copco by tamer on 2012-03-18 08:13
electrical connect of atlas copco elektronikon 1900 0701 04 ,ga50 vsd

—> Purchase or Repair:
#Atlas Copco by Riemann on 2013-07-17 15:44
Hey there, we are in urgent need of repair info for the Atlas Copco Elektronikon 1900 0701 05 controller. It stopped working and we need a replacement. Can you please provide some guidance or let us know where we can source a replacement quickly? Thank you.

—> Purchase or Repair:
#Atlas Copco by Rumen Nanev on 2009-08-11 18:32
I need more information for Atlas Cotco GA55

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.