#Atlas Copco by Hoky on 2010-10-13 04:35
does not start .please advice ,need manual book for the electronikon 1 repair .Thanks

—> Purchase or Repair:
#Atlas Copco by emilio doinog on 2013-02-21 14:43
we have a system failures troubles in our compressor atlas copco ga 45, and i dont know how to solve this troubles, i try to change the new elecktronikon display but did not work , but i think the new display may be lack of program because no display appear, The troubles are ; SYSTEM FAILURES AND SE…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by escelott presilda on 2012-08-19 11:07
Pls: sent me The Service interval of air ccmpresure GA75+ff

—> Purchase or Repair:
#Atlas Copco by marlon mejala on 2017-08-22 10:27
need to troubleshoot overload error of compressor

—> Purchase or Repair:
#Atlas Copco by Starla Irvin on 2012-03-08 08:32
Hello, I am reaching out on behalf of a client who is experiencing issues with an Atlas Copco controller with the part number 1900-0700-08. Can you please provide more information on troubleshooting and repair options for this particular model? Thank you.

—> Purchase or Repair:
#Atlas Copco by SALMAN on 2018-11-23 05:40
GA 37 part list manual is of importance to enable my company get genuine parts

—> Purchase or Repair:
#Atlas Copco by Naeem Mughal on 2008-01-30 11:14
Dear Sir,I have Electronikon controller in one of our Atlas Copco Compressor, now a days we are facing a problem that its one key is not functioning, therefore please quote us the price for the specified controller keypad if you have.Details of controller.Sr. No. 06994100012P. No. 1900 0701 24Best r…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Anil Kumar on 2015-10-28 10:28
please help me, controller shows fault 110300000000. I need your help to rectify the faultregarding Anil

—> Purchase or Repair:
#Atlas Copco by Richard Browne on 2008-06-06 11:31
Hi,Please send an Operations Manual for the Elektronikon II controller, which is fitted to our GA11-VSD P-10 Compressor.This is a requirement for us in complying with iso standards.Many thanks,Richard BrowneIQE Silicon Compounds Ltd.

—> Purchase or Repair:
#Atlas Copco by Yeison JF on 2008-02-05 00:18
I'm currently facing an issue with the Atlas Copco 1900 0701 02 Elektronikon. It seems like something has stopped working, but I'm not entirely sure what it does. Can you help me troubleshoot or provide more information on this model?

—> Purchase or Repair:
#Atlas Copco by ali boumlik on 2010-05-21 14:01
je cherche la documentation technique du op electronokon ii

—> Purchase or Repair:
#Atlas Copco by Miftah on 2012-03-07 10:41
We have using ZR 250 compressor since 5 year,and we need operating manual for our compressor, serial no 080239 year of manufacturer 2003Kind regardsMIftah

—> Purchase or Repair:
#Atlas Copco by Bowes on 2012-02-18 09:17
Hello, I'm reaching out regarding an Atlas Copco 1900-0700-08 controller that my client is having an issue with. Could you please provide details on troubleshooting or repair options for this part number? Thank you.

—> Purchase or Repair:
#Atlas Copco by Carlos Franchin on 2009-09-16 14:09
I can\'t start my GA75. When i power up, the Elektronikon II, show: time out inversor.What is this?What should I do?Please send to me: Manual Elektronikon II.too ,Thank you!!!

—> Purchase or Repair:
#Atlas Copco by Abdulla Aldulayme on 2016-02-29 11:47
Dear Sir or Madam,Would you please send me the maintenance manual for GA7 air compressor which I need it for the maintenance of our air compressors and to specify the required spare parts and order them from Atlas Copco Iraq.your fast response is a highly appreciated.Best regards,Abdulla Aldulayme—>…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by L.Akle on 2008-05-27 16:28
I need to repair an Electronikon II module Installed on an Atlas Copco GA45VSD Unit.The main symptom is that a relay output that controls the Element Cooling Fan, described as K01, does not come in. The rest of the program operates fine. We had to put on the Fan contactor ON directly, by-passing the…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Roger Bouyea on 2011-02-01 15:36
Need parts manual for GA55 Compressor

—> Purchase or Repair:
#Atlas Copco by Khondoker Razzakul Haque on 2010-07-09 21:58
I was told the Atlas Copco Electronikon 1900059812 is a controller unit that isn't working.

—> Purchase or Repair:
#Atlas Copco by ainsley whyte on 2012-09-04 23:44
fault converter

—> Purchase or Repair:
#Atlas Copco by paul busenbark on 2010-09-27 11:58
Retrofit install on a GA 75. Need a manual for the Elektronikon II. When retrofit installed we did no get a manual. We need to reset the maintenance required on unit to disable the red warning light since serviced.Thank you!

—> Purchase or Repair:
#Atlas Copco by labinot on 2014-12-29 11:54
Hello MR. I have the same problem, do you find the solution?

—> Purchase or Repair:
#Atlas Copco by ashraf ali on 2011-08-21 16:36
plese send complete user manual inverter&plc

—> Purchase or Repair:
#Atlas Copco by Juan Luis Llado on 2009-12-10 18:49
hi,I need a trouble shooting manual for a Atlas Copco Mod. GA 209

—> Purchase or Repair:
#Atlas Copco by V S yadav on 2012-03-31 13:14
Dear sirMy elektronikon\'s power of every 15 minut Please sugestV s yadav9351471656

—> Purchase or Repair:
#Atlas Copco by mukasakuraish on 2010-08-09 12:40
easy machine and good

—> Purchase or Repair:
#Atlas Copco by Mario Canaza on 2012-04-12 19:31
por favor requiero con urgencia los documentos referidos al compresor GA160-10AP-380V/50Hz, tengo problemas con la salida de aire que entrega humo.

—> Purchase or Repair:
#Atlas Copco by Eldric I. Santos on 2012-04-05 06:52
Very good air compressors

—> Purchase or Repair:
#Atlas Copco by Wawan Arif on 2012-05-07 04:14
help me please,I can not activate the remote start stop?

—> Purchase or Repair:
#Atlas Copco by P van Niekerk on 2009-06-12 13:42
Can you Pleas assist in an electronic copy of the manual on the Elektronikon II

—> Purchase or Repair:
#Atlas Copco by Kundzins on 2010-11-03 19:42
Electronikon 1900059812 controller not responding or displaying any information.

—> Purchase or Repair:
#Atlas Copco by elvis gonzalez on 2011-06-21 15:01
Need parts lis manual for this compressor , can you help me with this?

—> Purchase or Repair:
#Atlas Copco by devinder singh rawat on 2010-02-20 10:42
Dear sir,We want ELEKTRONIKON MANUAL please help methanking you

—> Purchase or Repair:
#Atlas Copco by virenderm mudgil on 2011-05-04 13:43
pl give the solution for vsd 37 compressor fault - oxfa31.

—> Purchase or Repair:
#Atlas Copco by AQEEL AHMAD on 2010-02-04 13:56
Dear sir,please give me a manual of ATLAS COPCO AIR COMPRESSOR GA75THANK\'S & REGARD

—> Purchase or Repair:
#Atlas Copco by KARTHIKEYAN on 2009-12-24 10:33
Manufactured 2007, ATLAS COPCO AIRPOWER - Belgium. We need the electric drawings and ELEKTRINIKON II TECHINICAL AND USER MANUAL

—> Purchase or Repair:
#Atlas Copco by taabache noureddine on 2016-11-17 22:56
all informationc about model ga 90 FF thank;s

—> Purchase or Repair:
#Atlas Copco by PREMARATNE W.P. on 2010-02-16 12:33
Dear Sir,We have 3 No. of this type of air compress, and one of this can\'t start. the fault indication was (104 ) system faulty I checked input voltage and tightened call connection of regulator but all are OK Again i tried but not start. Can you please tell what i wants to check more. When i repla…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Albayrak on 2015-07-20 07:20
The Atlas Copco Elektronikon II 1900071012 compressor controller is not working properly.

—> Purchase or Repair:
#Atlas Copco by Pandaya on 2009-03-29 07:14
Dear sirwe need operating instruction for air compresor atlas copco GA75type 1900-0581-05LD4 (Display using seven segmen)Thank you very muchregardpandaya

—> Purchase or Repair:
#Atlas Copco by Frank Horna on 2008-02-21 21:47
Please, it can send me a version recent envelope the technical manual of Elektronikon II

—> Purchase or Repair:
#Atlas Copco by Ron Ledwell on 2008-03-18 19:52
The unit that typically manages the air compressor's operation and monitoring system is showing abnormal behavior. It is not displaying the usual readings or responding as it normally would.

—> Purchase or Repair:
#Atlas Copco by S. Natarajan on 2011-06-01 13:17
Request both Instruction Manual and Spare Parts Manual for GA55 Air Compressor

—> Purchase or Repair:
#Atlas Copco by Abdul Hafeez on 2008-06-26 16:16
Replace fan thermal switch.... i think problem is not in the module but it is in the thermal switch only... rgds. A H S

—> Purchase or Repair:
#Atlas Copco by Faizal on 2015-05-26 04:53
Hello we operating oil free compressor ZT110 and the electronikon displays an error which reads as follows: system failure 7001please send me trouble shooting and solution to this problem.thank you

—> Purchase or Repair:
#Atlas Copco by JOSE EMMANUEL PEREZ MTZ on 2011-08-05 16:37
GOOD MORNINGWE NEED SUPPORT A TECHICAL MANUAL FOR COMPRESOR GA55FF TANKS

—> Purchase or Repair:
#Atlas Copco by Ron Reichl on 2010-09-23 22:28
The Atlas Copco Electronikon 1900059812 is displaying Error Code 1022, and the alarm for low oil pressure keeps triggering. Equipment is currently down, and production is halted. Please provide urgent assistance to resolve this issue. Thank you.

—> Purchase or Repair:
#Atlas Copco by sidy sarr on 2022-02-21 15:25
Bonjour mon compresseur atlas copco ne demarre pas quand je le met sous tension il affice une defaut 110300000000. veuillez m'informer de la signification de cette alarme (110300000000) et comment supprimer

—> Purchase or Repair:
#Atlas Copco by moolchand on 2009-12-29 07:43
i want to know what point change when elktornikon control mode change local to remote

—> Purchase or Repair:
#Atlas Copco by Ramses Rendon on 2010-09-14 23:27
We need the how program a compressor atls because, only be in load

—> Purchase or Repair:
#Atlas Copco by lang tu on 2011-05-13 22:20
Dear Madam/Sir,I would like to know the service manual of Air comp Atlas copco GA55.Thank very muchLang tu

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.