Atlas Copco Service & Repair Forum

We have an Atlas Copco GA-75 that is about 12 years old. It has an Electronikon Controller that will not reset. Do you do diagonostics, repairs, replacements, etc.??

—> Purchase or Repair: Ticket Image

— Posted by Scott Fallon on 2007-12-06

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by DIMITRIS ZAOURIS on 2008-05-08 09:05
Dear sirWe are a food industry in Greece and we have two ATLAS COPCO GA115air compressors and i have a problem with the keyboard of the one unit.The electronikon screen works but when i want to change parameters the push buttons not work.I think that i need only the front keyboard.Can you provide th…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by mike geary on 2011-07-20 22:32
Please send manual as PDF for Atlas Copco Compressor GA55, thank you.

—> Purchase or Repair:
#Atlas Copco by Daniel Clifton on 2009-09-11 18:32
Need manual to change setpointsThank you

—> Purchase or Repair:
#Atlas Copco by Faizal on 2015-05-26 04:53
Hello we operating oil free compressor ZT110 and the electronikon displays an error which reads as follows: system failure 7001please send me trouble shooting and solution to this problem.thank you

—> Purchase or Repair:
Buenas tardes,un gusto saludarles desde Perú.El motivo de este mensaje es para solicitar su ayuda con un problema de compresor atlas copco modelo GA22P, controlador modelo MKIII 1900070007Resulta que no arranca el motor de compresor. No muestra ninguna alarma, la temperatura es 24°C.La presión es 0 …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by José Moreno on 2017-07-24 20:37
I need to reset conditions

—> Purchase or Repair:
#Atlas Copco by tran hoang dung on 2009-05-07 10:21
Dear Sir/MadamI Want to know the cost of Electronikon regulator ( 1900 0710 31) and where can I play an order shortly. Best regards

—> Purchase or Repair:
#Atlas Copco by JERRY TOO on 2010-03-04 03:49
DEAR MR/MS, I NEED YOUR HELP. DO U POSSIBLE SENT ELEKTRONIKON 1900 0700 03 OF THIS UNIT INSTRUCTION MANUAL FOR US? BECAUSE WE GET SOME PROBLEMS FOR THIS UNIT. AND PLEASE REPLY AS SOON AS POSSSIBLE. THANK YOU VERY MUCH!!!

—> Purchase or Repair:
#Atlas Copco by Abdul Hafeez on 2008-06-26 16:23
if any one problem with screw compressor of any brand.... please do not hesitate to contact us.... regards A H S

—> Purchase or Repair:
#Atlas Copco by omar on 2016-12-08 18:36
at work some of our electrical tech put 110v for input 24v that cause problem where compressor controLler is off i found SMD input Resistance is damage i change smd where controller is work without data what i do, also i need wiring digram for compressor where compressor data is:ATLAS COPCOpart no: …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Ludwig Valderrama on 2015-11-17 19:49
Controller display 110200000000 messageNeed manual & programming procedure about Elektronikon controllerPart # 100070124

—> Purchase or Repair:
#Atlas Copco by haythem on 2011-04-10 11:56
hello,please I have compressor atlas copco ga 11 ff but I dont have the electrical manuel and mecanical manuel and manuel user please can you send me manuel .

—> Purchase or Repair:
#Atlas Copco by Engineer Akram Sadiq on 2008-09-13 19:52
i have a large measurement offset in the reading of the delivery air pressure transducer . can I Adjust it ?? . I can not see any screw or way to adjust this offset in the transducer .

—> Purchase or Repair:
#Atlas Copco by taabache noureddine on 2016-11-17 22:56
all informationc about model ga 90 FF thank;s

—> Purchase or Repair:
#Atlas Copco by poovalingam kesavan on 2012-11-25 10:08
dear sir, i need GA90VSD ELECTRICAL AND VFD AND CONTROL WIRING DIAGRAM. CONTROL PANAL TYPE 1900255003,SERIAL NUMBER:201201259;SERVICE DIAGRAM NUMBER:9820314001CONTROL VOLTAGE 115/24VAC,SUPPLY VOLTAGE 380/460V,RATED CURRENT 225/171A,MAX MOTOR POWER 90KW.

—> Purchase or Repair:
#Atlas Copco by DAN on 2012-02-22 19:28
Hello, I am reaching out regarding part number 1900-0590-12 for an Atlas Copco Elecktronikon controller. The client is experiencing issues with the controller and requires assistance. Can you please provide information on how we can proceed with this matter? Thank you.

—> Purchase or Repair:
#Atlas Copco by Petre Pistol on 2019-08-13 05:50
I have a Atlas Copco air compressor controller serial number 1900 0701 23.On display is a alarm code 11 02 00 00 00 00.How can it be repaired?Thank you!

—> Purchase or Repair:
#Atlas Copco by phillip on 2017-12-07 09:56
how to i clear ERROR 1002000000

—> Purchase or Repair:
#Atlas Copco by Lawrence Angelo on 2010-09-26 10:52
i just need servise manual and electrical diagram we have two compressor of GA 90 but supplayer did not send us service manual and diagram so please send me regards

—> Purchase or Repair:
#Atlas Copco by bunyamin diricanli on 2020-03-23 09:11
Hello Dear Sir / Madam;we have an atlas copco compressor Model : GA 55 (50 hz european year :1990 ) and I dont have manuel would you send us user manualCompressor label information is like bottom;Serial ARP 889924Year 1990type GA 55Best regardsBunyamin Diricanli

—> Purchase or Repair:
#Atlas Copco by eng:adel on 2009-10-19 12:22
PLEASE WE NEED PRICE FOR THIS ITEMS Item: 1 Qty :2 Elektronikon touch screen . Ser no 31100904329Part no 190071032 please answer before 24/10/2009 Best Regards

—> Purchase or Repair:
#Atlas Copco by ismael on 2008-10-03 14:46
ìm on the same situation. Would you mind to send me the manual of electronikon I

—> Purchase or Repair:
#Atlas Copco by Peder Yang on 2010-11-29 07:12
My GA 50VSD has a Simens Simovert inverter. 6SE7031-5EF20-OBBO. I have an E message on the screen. According to the manual I need to replace CU board. Can you help?

—> Purchase or Repair:
#Atlas Copco by Eta Leonard on 2013-12-10 12:55
GA 37 part list manual is of importance to enable my company get genuine parts

—> Purchase or Repair:
#Atlas Copco by Le anh phi on 2022-01-14 09:37
Fault: starter feedback contact , shutdow

—> Purchase or Repair:
#Atlas Copco by Sojitra on 2010-09-18 06:20
The Atlas Copco Elektronikon 1900070124 is a controller that is currently not working and needs attention from the maintenance team.

—> Purchase or Repair:
#Atlas Copco by FCO. VILLELA on 2008-01-30 21:41
Hi,i have some problems whit the mastercontrol elektronikon i want to say if you can to send my the users manual

—> Purchase or Repair:
#Atlas Copco by james mulqueen on 2011-07-13 19:58
machine trips from time to time with same fault convertor motor timeout need to know possible causes please have checked usual things rmba unit and cables crc counters count in units of 1on a only. turn power of and these reset some help please

—> Purchase or Repair:
#Atlas Copco by Harendra sharma on 2012-05-02 06:25
Atlac copco is outstanding air compressor

—> Purchase or Repair:
#Atlas Copco by hmd on 2011-09-08 10:05
Dears,I need a help for a failure massege of elektronikon panel which its part no. is (2906 0595 05). the failure massege is :22200000210000009820 3978 10when i run this panel, this massege appears and remains in display without any change and no step done yet!please, advice me for this problem and …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by jerry dillashaw on 2014-11-02 18:57
Experiencing issues with my Atlas Copco Elektronikon II 1900071011 Control/Display Module. Need urgent repair service as it's impacting industrial operations. Any technician available to fix this unit

—> Purchase or Repair:
#Atlas Copco by steve on 2011-12-21 22:08
Please send asap, manual on GA7thkx

—> Purchase or Repair:
#Atlas Copco by Sasa Dincic on 2017-11-04 08:16
I need a service manual..I buy GA50VSDff and i have a problem with compressor..

—> Purchase or Repair:
#Atlas Copco by BOUSBA abdenacer on 2012-08-01 12:55
nous vous prions de bien vouloir nous envoyer une copie format PDF des documents accompagnant le compresseur GA 22 ( manuel d\'utilisation et d\'entretien du compresseur ainsi que celui du régulateur ELECTRONIKON.remerciements anticipés

—> Purchase or Repair:
#Atlas Copco by Glen on 2011-12-29 19:39
I have had the following error message appear on my Elektronikon 2 controler and was wondering if any one can explain it to me?Glenmessage 11200000B_Sw 010531_Thanks,Glen

—> Purchase or Repair:
#Atlas Copco by Djamel on 2009-01-22 16:56
dear sir;in our site we have ATLAS COPCO ZT90 compressors with an ELEKTRONIKON regulator, one of them has a reppetitif shut down by \" SYSTEM FAULT\" with a code of th error, somtimes with \" 111101000 106\" code, and somtimes with \" 200 \" code.we haven\'t any documentation for this regulators, en…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by ARMANDO MARTINEZ RIOS on 2010-09-13 17:45
PRODUCT TIPO GA55NO. SERIE AII 464066MAX. PRESSURE (g) psi 107FREEAIR DELIVERY cfm 360MOTOR POWER hp 73.8max. speed r/min 3600year of construction 1998

—> Purchase or Repair:
#Atlas Copco by hieu le minh on 2008-03-12 12:35
I want to control elektronikon panel of air compressor model ZT110.Could you tell me how I can get user manual elektronikon regulator.Pls, feedback to me as soon as.Thanks and best regards.Hieu Le MinhBritish American Tobacco- Vinataba (JV) Ltd.,Vietnam

—> Purchase or Repair:
#Atlas Copco by Mina on 2021-12-20 15:22
Dear Sir/MadamI have Atlas Copco GA55 compressor. Now Elektronikon Master Control doesn't display anything except 100400000000. The compressor cannot be started for operational.PN : 1900070106 What's wrong with the Control? Please Give me information. Thank You

—> Purchase or Repair:
#Atlas Copco by Ban on 2011-03-14 09:28
Please send it to me

—> Purchase or Repair:
#Atlas Copco by Gabriel Gonzalez Ramirez on 2010-09-06 03:24
I need The manual of compresor GA55 please send to e-mail above indicated. Soo as possible

—> Purchase or Repair:
#Atlas Copco by janusz on 2009-02-16 11:51
We have 2 compressores (manufactured by Atlas Copco) with model of engine XAS 175 and XAS 175N. This compressores are about 10 years. Where I can find user manual?

—> Purchase or Repair:
#Atlas Copco by Paulo Oliveira on 2016-10-24 10:37
#Atlas Copco by barhoumi on 2011-05-26 20:55
le meilleur marque international

—> Purchase or Repair:
#Atlas Copco by zafar ansari on 2010-03-13 08:02
dear sir.we need manuals of ATLAS COPCO GA55AFF for maintenance puropose.Kindly do this favor and provide if possibility is there through soft copy via email.thanks

—> Purchase or Repair:
#Atlas Copco by Chiranjeevi Raju on 2012-04-16 11:55
Dear sir,please send the Spare parts manual for GA22 air compressor for ordering spare from the local dealer.Thanks and regards,Chiranjeevi RajuManager- Maintenance.

—> Purchase or Repair:
#Atlas Copco by Giar Ronald on 2009-09-06 00:15
We want to buy Elektronic RegulatorParts No. 1900 0701 24For Atlas Copco GA 160 Compressor

—> Purchase or Repair:
#Atlas Copco by Martín German on 2013-01-29 20:43
Hello,I need the manual of air compressor Atlas Copco brand model: GA55FFThank youMartín Germán

—> Purchase or Repair:
#Atlas Copco by yasser on 2016-08-21 13:20
prat mr: 1900070123serial nr: 06972600304thankful

—> Purchase or Repair:
#Atlas Copco by Senthil Kumar P on 2015-03-29 21:49
The Atlas Copco Elektronikon II 1900071012 compressor controller is displaying abnormal behavior in the warehouse.

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.