Atlas Copco Service & Repair Forum

J\'ai deux compresseur atlas copco GA 75 FF + ET j\'ai besoin du schéma electrique pour COMPRESSEUR GA 75 FF+

—> Purchase or Repair: Ticket Image

— Posted by mourad on 2016-09-13

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by NEMICHE on 2009-05-17 17:18
Dear sir;We have 05 elektronikon regulator in our site installed on Atlas copco Compressor and we have some problems on sequences configuration changing the start up priorities 1,3,2,number 4 compressor we want to change this priority as follow 1,4,3 and 2We don\'t have the acces to the software for…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by selmo on 2012-04-15 19:38
gostaria de receber por emaisl o manualde operacione e control de ga75 elcktronikonll

—> Purchase or Repair:
#Atlas Copco by DKIOUAK on 2011-03-01 12:21
bonjourVeillez m\'envouyer le manuel d\'utilisation et de maintenance du compresseur GA 30 Atlas copco.Bien cordialement.

—> Purchase or Repair:
#Atlas Copco by moaaz ahmed on 2021-02-09 12:01
Screen Control PN1900070106QTY:1

—> Purchase or Repair:
#Atlas Copco by trushar on 2012-02-04 09:25
I need electronikon ll manual for changing parameters in atlas copco compressor model - GA30AWFF AT THE EARLIEST POSSIBLE MEANS AT THE PRESCRIBED EMAIL ADDRESS REGARDS,TRUSHAR THAKKAR

—> Purchase or Repair:
#Atlas Copco by Reinier Swanepoel on 2014-02-20 02:00
Changed out display panel about 6mnth ago, display stops working again. Tested the supply and found 24v going in but display is not working . Could it be a coincident or maybe a bad display panel.Advice

—> Purchase or Repair:
#Atlas Copco by gregory uribe on 2009-10-12 17:46
por fabor nesecito el manual de usuario e instalasion de el modelo1900 0700 05. si pueden conserguirme esta informacion acerca de este equipo por favor enviarmela es que tengo un problma y no tengo los datos necesario para hacer la reparacion...

—> Purchase or Repair:
#Atlas Copco by Bing Lopez on 2011-07-27 01:22
GA 75 Electronikon II controller module presently instlled was bug down and the parameters of the compressor can not be seen at the display monitor

—> Purchase or Repair:
#Atlas Copco by Charles Rachlis on 2015-07-23 17:20
Hey there, we're in need of a replacement for an Atlas Copco Elektronikon II 1900071012 Compressor Controller. Unfortunately, we couldn't find one. Can you provide us with repair information or let us know where we can source this part ASAP? Thanks!

—> Purchase or Repair:
#Atlas Copco by José Valdir dos Santos on 2013-08-16 22:32
The Atlas Copco Elektronikon 1900 0701 05 unit is still down. Please provide a

—> Purchase or Repair:
#Atlas Copco by Gul bahar Shah on 2009-03-09 18:32
Dear sir /madam we have need trouble shooting guide .

—> Purchase or Repair:
#Atlas Copco by GANESH on 2009-06-06 12:45
dear sir, i have elektronikon II unit but some problem is inside i want some information ragarding cirquit digram or IC Details used in unit i hope u will give me response kindly.. Thanks ganesh

—> Purchase or Repair:
#Atlas Copco by Pedro Aparicio Arias on 2008-11-17 18:49
ELECTRONIKON technical Manual..-------------------------------------------------------------------------------- Posted by Pedro Aparicio on Sunday, November 17 2008Dear Sr.I Need ELECTRONIKON II technical Manual..Pedro AparicioCoats Cadena S.A.Phone: (511) 612-6200 Ext.: 450LimaPeru—> …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Elson Carvalho on 2011-04-19 11:22
How can I repair this alarm???

—> Purchase or Repair:
#Atlas Copco by Rakesh kumar on 2014-04-01 23:07
not able to reset Alarm 110300000000 for GA200 controller

—> Purchase or Repair:
#Atlas Copco by kamal on 2011-01-15 16:23
je vaudrait logicel qui detect les pannes du elektronikon module avec la methode qui connect avec pc

—> Purchase or Repair:
#Atlas Copco by Nadid Burbar on 2012-03-08 12:32
The Atlas Copco 1900-0700-08 controller unit is malfunctioning and needs attention. Please look into it as soon as possible. Thank you!

—> Purchase or Repair:
#Atlas Copco by Don Crawford on 2014-02-14 21:58
Looking for repair for my Atlas Copco Elektronikon II 1900071011 Control/Display Module. Unit is not displaying any info or responding to inputs. Need someone to fix this ASAP to get our operations back up.

—> Purchase or Repair:
#Atlas Copco by Torbjörn Liljegren on 2008-10-17 06:54
send a GA22 manualKind regardsTorbjörn Liljegren1st EngineerM/T Evinco

—> Purchase or Repair:
In our plant, we have 2 nos GA 22+ compressors installed & in service for about 4 years. We would like to have Part manual & service manual with exploded drawings for use & reference.

—> Purchase or Repair:
#Atlas Copco by K. Nageswara Rao on 2011-10-28 10:51
Technical specifications for GA7FF Atlas Capco Air compressor please

—> Purchase or Repair:
#Atlas Copco by MUHIRWA Prosper on 2009-10-24 08:28
I NEED MANUEL FOR ATLAS COPCO GA55AFFTHANKS.

—> Purchase or Repair:
#Atlas Copco by DEBASISH GOUDA on 2009-09-15 10:00
Electronikon controller is a very good controller.

—> Purchase or Repair:
#Atlas Copco by Ketan J Bhatt on 2012-08-06 13:04
Dear Sir,Pls send elect Drawing for above mention model.RegardsKetan Bhatt

—> Purchase or Repair:
#Atlas Copco by DAMBO WALSON on 2009-01-07 16:58
SIR.THE ELECTRONIKON ON OUR GR-132 COMPRESSOR DOES NOT RESPOND TO COMMANDS. PRESSIND THE FUNCTION KEYS , NO RESPONSE COMES ON. ALL WE SEE IS THE GENERAL ALARM THAT IS PERMANENTLY ON . EVEN WHEN THE FIELD DEVICES WERE DISCONNECTED THE ALARM REMAINED AND SUCH NOTING FOR NOW COULD BE DONE. WE NEED A TE…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by victor riquelmesaavedra on 2009-09-05 13:57
me podrian enviar el manual de usuario de:atlas copco compresor de aire estacionariosGA50VSD FFYA QUE HAY UN PROBLEMA EN LA PARTIDA PRODUCTO DE ESTO EL EQUIPO SE DETIENE Y EL ELEKTRONIKON ARROJA ERROR 177 .SE AGRADECERIA MUCHO SU AYUDA .SALUDA ATTE. A USTED VICTOR RIQUELME INGENIERO ELECTRICO .—> …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by N.GOPISANKAR on 2011-09-29 09:18
GA 30 VSD MODEL ATLAS CAPCO COMPRESSOR ELEKTRONIKAN 2 DISPLAY SOS\" COMPRESSOR MOTOR CONVERT TIME OUT\"

—> Purchase or Repair:
#Atlas Copco by Kip Bauer on 2008-10-16 17:07
I have a compressor with the electronikon II on it And having problems with the compressor tripping main breaker. Almost 100% positive about when it does it. happens after unload motor stops then when it restarts motor, it trips breaker, But not all the time. Not sure if control is starting motor un…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Gleem Arena on 2012-06-18 21:49
Productos excelentes.

—> Purchase or Repair:
#Atlas Copco by ROWLAND HILL on 2007-06-29 12:18
PHONE 614 488-1151I NEED THESE REPAIRED. cAN YOU DO?

—> Purchase or Repair:
#Atlas Copco by Piyush rajgor on 2016-11-04 06:01
Sir pls inform me what is the mean of this alarm (100300000000) and how to remove thisThanking you

—> Purchase or Repair:
#Atlas Copco by Martin Hernandez on 2020-08-12 19:46
I need your help.I need to clear this alarm in my air compressor , but I have not the manual or to know what kind of error is?Could you helpme about it please?Error Display 110200000000 .Regards.

—> Purchase or Repair:
#Atlas Copco by Mohammad Reza Dadjoo on 2009-08-12 06:11
i need manual ga75

—> Purchase or Repair:
#Atlas Copco by Karl Halder on 2011-08-06 11:21
The controller on the Atlas Copco Elektronikon II 1900 0710 12 is malfunctioning, affecting the production line. Urgent repair service is needed to resolve the issue and resume operations

—> Purchase or Repair:
#Atlas Copco by Chookeat T. on 2008-10-01 10:55
Dear Sr.I Need ELECTRONIKON II technical Manual.Best regards,Chookeat T.choo_oh@hotmail.com

—> Purchase or Repair:
#Atlas Copco by ibrahim abdel salam on 2008-09-10 00:36
manual and offer to get repaired or new panel

—> Purchase or Repair:
#Atlas Copco by rickey on 2009-08-17 15:02
The only thing that show up on the display is 110200000000

—> Purchase or Repair:
#Atlas Copco by Manoj Bhandarkar on 2010-08-19 14:51
kindly send ga55 manual.

—> Purchase or Repair:
#Atlas Copco by cesar del palacio on 2009-11-07 18:02
We need the manual for atlas copco compressorTNKS!!

—> Purchase or Repair:
#Atlas Copco by ahmed gomaa on 2012-03-14 09:59
GA15FF compressor maintenance manual

—> Purchase or Repair:
#Atlas Copco by eng:adel on 2009-10-19 12:22
PLEASE WE NEED PRICE FOR THIS ITEMS Item: 1 Qty :2 Elektronikon touch screen . Ser no 31100904329Part no 190071032 please answer before 24/10/2009 Best Regards

—> Purchase or Repair:
#Atlas Copco by dehner on 2013-08-03 23:32
The Atlas Copco Elektronikon 1900 0701 05 is not working. Please check and troubleshoot as needed.

—> Purchase or Repair:
#Atlas Copco by harish nyati on 2012-05-24 02:56
Sir,We have procured one item from you and it,s name as per your sticker affix on item is \"spacer part no 1622340000\"Please let me know that Element oil_seperator part no 162234000 of ga55awp is same as given above spacer.

—> Purchase or Repair:
#Atlas Copco by Dennis on 2011-11-01 06:57
Hello, I am reaching out on behalf of a client regarding an issue with an Atlas Copco Elektronikon II 1900 0710 12 controller. Can you please provide information on potential repairs or troubleshooting steps for this specific part? Thank you.

—> Purchase or Repair:
#Atlas Copco by NAGENDAR BAHADUR SINGH on 2015-11-04 05:53
Dear Sir,Pleased to request a manual for atlas copco GA-55 model,we are currently doing PM on our machine andwe need to identify the parts to purchase. And we need to knowhow to dismantle the element/air end step-by-step. THANKS, NAGENDRA BAHADUR SINGH SR. ENG.K.M.SUGAR MILLS LTDS MOTINAGAR FAIZABAD…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Marcos Bartoloni on 2008-09-29 18:52
Good afternoon people. I need a PDF copy of the elektronicon 1900 0700 03 control module, because we have an error that its shown on the display, and we want to start and investigation of it, but we need the information about the control module. Reggards Marcos Bartoloni EDELCA, VENEZUELA—> …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Haseeb on 2012-12-24 06:14
Dear SirI need Atlas Copco GA55 Plus electrical power and control manual pleas send meThanking YouHaseeb

—> Purchase or Repair:
#Atlas Copco by OTOVWE ISAAC on 2011-06-06 12:17
I require the technical manual for GA 18 F, please

—> Purchase or Repair:
#Atlas Copco by Mohammad Tazuddin on 2007-10-20 08:12
dear sir, we have 4 instrument air compressor operating in MCC, No 1 compressor is master control for 3 compressors.we have one problem in atlas copco instrument air compressor no 3 this is not communicating with instrurment air compressor 1 and not sending to DCS also it means all process parameter…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by reza on 2019-10-07 07:57
i have zr425 compressor that error 110200000000 appear in display,i think time keeper chip destroyed and need reprogramming .can some one help me fix it(i need data files for this compressor for DFM4WIN software)

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)