Atlas Copco Service & Repair Forum

Are you mail file it?. Thank you very mach.

—> Purchase or Repair: Ticket Image

— Posted by nguyễn minh thuận on 2009-11-23

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1315 Comments

#Atlas Copco by Miftah on 2012-03-07 10:41
We have using ZR 250 compressor since 5 year,and we need operating manual for our compressor, serial no 080239 year of manufacturer 2003Kind regardsMIftah

—> Purchase or Repair:
#Atlas Copco by Gerhard Wagner on 2013-07-30 09:32
The Elektronikon 1900 0701 05 controller board just failed on machine 3, requesting immediate replacement for continued operations.

—> Purchase or Repair:
#Atlas Copco by Kolsky on 2012-11-02 10:45
Do you have an Atlas Copco Elecktronikon 1900-0590-12 controller available for sale or repair? Our unit went down, and we need to keep production running.

—> Purchase or Repair:
#Atlas Copco by Myint Thein Oo on 2012-03-12 04:01
good to use for various compress air needs

—> Purchase or Repair:
#Atlas Copco by musa batari on 2008-06-02 16:28
we have twoof this type of compressor in my section for bag filters, resently we had a problem of the display unit went off completly. we try to trace the problem but is difficult becouse the circuit diagram was too tiny to read. pls. can you send a pdf copy to me so that it will help to trace any p…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by babu on 2012-06-21 18:25
turbo compressor not start due to starter contractor open,

—> Purchase or Repair:
#Atlas Copco by ThanhDat on 2011-04-03 07:38
Dear service Manager!We are using Atlas Copco Compressor GA 15, A MESSAGE IS APPEARING IN LCD THAT \"SYSTEM FAILURE 200\"PLS TELL ME THAT HOW I CAN REMOVE THIS ERROR ,PLS REPLY ME URGENTLY.THANKS

—> Purchase or Repair:
#Atlas Copco by Rakesh K Sharma on 2011-04-10 05:23
I have two units Screw Compressor Atlas copco GA 22 & one GA 45There is problem in the electrical.I need an wiring electrical for compressor Atlas Copco GA 22,And elektronikon 1 controller manual.please send me to wiring electrical & manualBest Regards,Rakesh SharmaIndag rubber.ltdNalagarh,SolanHima…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by NILEAYSH GHODAKE on 2013-07-22 23:32
The Atlas Copco Elektronikon 1900 0701 05 unit in the shop is not working.

—> Purchase or Repair:
#Atlas Copco by Musza³owski on 2012-03-07 23:32
The Atlas Copco 1900-0700-08 unit is not functioning properly. It's described as a controller, but I'm not completely familiar with its specific function yet.

—> Purchase or Repair:
#Atlas Copco by waleed on 2011-05-11 16:27
we need wiring diagram of xams 856

—> Purchase or Repair:
#Atlas Copco by Ahmet Seyrek on 2013-03-13 21:14
Dear sir or Dear MadamAfter ten days from our 8000 hours maintenance, we have now a starter feedback contact fault in our GA 160FF Model Atloas Copco Compresor.What would you like to recommend for this problem as solution?Thanks....(Compressor model : GA 160FF)

—> Purchase or Repair:
#Atlas Copco by mohamed lakhal on 2011-03-15 14:12
i want the manuel afficheur electronicon

—> Purchase or Repair:
#Atlas Copco by zhao on 2009-02-23 06:42
Elektonikon user manual

—> Purchase or Repair:
#Atlas Copco by Frank Horna on 2008-02-21 21:49
Please, it can send me a version recent envelope the technical manual of Elektronikon II

—> Purchase or Repair:
#Atlas Copco by labinot on 2014-12-29 11:54
Hello MR. I have the same problem, do you find the solution?

—> Purchase or Repair:
#Atlas Copco by Pankaj kumar gochhayat on 2015-06-09 05:54
Dear sir,Kindly provide us mentioned guide and parts manuals for maintenance the 3 nos of new compressor

—> Purchase or Repair:
#Atlas Copco by PAKACHENA MASENGWE on 2012-01-17 09:45
How are you, l kindly request for a maintenance manual for GA11FF compressor. We are having frequent vee belts breakages (at least one breakage per month) on compressors serial numbers CA1702888 and CA1702889 .PRODUCT NO. 8153001568. RegardsPakachena MasengweJunior Engineer Asset planning and utilis…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by SHAJAN PANIKAR on 2015-09-17 08:25
MACHINE AND WORKING IS VERY GOOD

—> Purchase or Repair:
Could you please confirm if the Atlas Copco Elecktronikon 1900-0590-12 controller is still supported, and if replacement parts are available for it? Thank you.

—> Purchase or Repair:
#Atlas Copco by alfonso garcia on 2011-02-11 21:39
Good day gents!May we have a copy of the Elektronikon controller manual. Also the manual of the Elektronikon Input Module, we are having issues with the input from the dewpoint sensor.Many thanks....

—> Purchase or Repair:
#Atlas Copco by David on 2009-08-03 11:40
Very interesting and really needed manual

—> Purchase or Repair:
#Atlas Copco by alinavaz merchant on 2012-01-05 12:19
dear sir,my atlas copco scrow air comprassor display folt folt 200 so what can i do pleas give your manualthanksalinavaz merchant

—> Purchase or Repair:
#Atlas Copco by Wayne Ellis on 2010-02-05 17:29
Could you supply a user manual for the elektronikon controler

—> Purchase or Repair:
#Atlas Copco by Elvis rojas on 2021-12-13 03:21
Buenas noches,muy buenos equipos, requiero manual de programación , no permite aran que manual, solicito clave para su arranqué automático

—> Purchase or Repair:
#Atlas Copco by Leonardo Ziegler on 2012-01-11 19:48
I need a manual for this Elektronikon with part number 1900 0700 05 . I hope there\'s someone can help my problem.

—> Purchase or Repair:
#Atlas Copco by satish on 2009-07-27 16:03
we are using 12 numbers of screw compressor from yours. it good in service we need the above document

—> Purchase or Repair:
#Atlas Copco by ED HAYWARD on 2006-10-24 20:33
PART# 1900-05-9812 REPAIR PRICE AND TIME FRAME. THANKS ED HAYWARD

—> Purchase or Repair:
#Atlas Copco by Hassan on 2009-05-11 12:14
Dear Sir,I have Atlas Copco : Compressor GA30 VSDInverter Siemens : 6SE7027-2ED61-ZController Atlas Copco: 1900 0701 82Compressor Controller Atlas Copco:1900 0701 06I had problem in inverter, the Siemens maintenance was solved it.My problem is: How to set communication panel with control? And data f…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by SABINUS IROEGBU on 2011-07-06 13:44
The display on our Atlas Copco Electronikon 1900-0701-04 is malfunctioning, disrupting production. Urgently need repair service to resolve the issue and restore operations to normal.

—> Purchase or Repair:
#Atlas Copco by Pourya on 2017-05-11 19:34
hi i have problem in ZR200 compressor . this alarm comes and compressor shtting down : 110200000000what is the meaning this alarm please send me alarm code thank you

—> Purchase or Repair:
#Atlas Copco by Paul Gunkel on 2009-03-13 15:59
I have a newer GA 55 plus compressor and lost my CD that explains evry thing about the compressor and was wondering if I could by another one?

—> Purchase or Repair:
#Atlas Copco by imran khan on 2010-03-10 15:42
i need a user manual in vfd siemens simovert ihave in aproblem send me a user manual

—> Purchase or Repair:
#Atlas Copco by alfonso garcia on 2011-02-11 21:34
electrican diagram electronicon please can help me whit this problem

—> Purchase or Repair:
#Atlas Copco by Remegio B. Dar on 2012-07-01 18:41
Dear Sir/Madam,I work in gulf glass manufacturing company,kuwait,we have 3 atlas copco compressor ZR-250,we are facing the control panel overheating and the controller electronikon be come damage,please give me an advice how to reduce the hot inside the panel and what equipment we need to fix in the…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by dave Urwin on 2009-01-03 10:04
Dear Sr.I Need ELECTRONIKON II technical Manual..

—> Purchase or Repair:
#Atlas Copco by STEVEN LAMBERT on 2009-08-25 20:05
FROM A ELEKTRONIKON TO ELEKTRONIKON II

—> Purchase or Repair:
#Atlas Copco by thein than oo on 2011-02-13 00:20
the display showed the inop and cannot run the unit.

—> Purchase or Repair:
#Atlas Copco by EDGAR RAMOS on 2013-05-07 02:33
Do you have a controller available for the Atlas Copco GA45 1900.0590.74 unit? Our production is down and we need one urgently to keep running. Thank you!

—> Purchase or Repair:
#Atlas Copco by juan manuel on 2010-01-21 16:17
please send me the users manual for controller elekctronikon compresor ga30tanks

—> Purchase or Repair:
#Atlas Copco by Muhadhir Baba on 2011-05-22 06:21
Request GA75 AIR COMPRESSOR MANTENANCE MANUAL

—> Purchase or Repair:
#Atlas Copco by Terschluse on 2013-02-11 09:39
The Atlas Copco GA45 1900.0590.74 controller unit is displaying unusual behavior in the warehouse.

—> Purchase or Repair:
#Atlas Copco by sinem_kasapciyann on 2011-06-11 02:24
The unit isn't working, please check it.

—> Purchase or Repair:
#Atlas Copco by nitis pooasa on 2009-12-14 13:29
I work for Circuit Electronic Industries public ltd in thailand we use 8 ZT90compress air machine I woud like to get the troubleshooting for electronikon control module

—> Purchase or Repair:
#Atlas Copco by adilalmusawi on 2012-10-24 08:40
HiI need the wiring diagram (wiring Diagram) for Electronikon II G37 for Atlas Copco Machine (Compressor Machine). I have the wiring diagram (printed on papers) but it is so small that could not help me to rearrange the wiring for it.

—> Purchase or Repair:
#Atlas Copco by Piotr on 2011-05-10 15:54
Good day,I\'m chief engineer on the vessel and I have new Atlas Copco compressor on board, type GAP26P whit graphical display. Because I use this copressor for control air, I would like to activate the automatic restart function. Unfortunately there is some password. Can I recive this password by e-…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Haseeb on 2012-12-24 06:14
Dear SirI need Atlas Copco GA55 Plus electrical power and control manual pleas send meThanking YouHaseeb

—> Purchase or Repair:
#Atlas Copco by Randy Deel on 2011-05-23 20:16
I would like to have an error code list for the DM45.ex. 157FMI18

—> Purchase or Repair:
#Atlas Copco by alex on 2009-06-04 03:02
necesito manual ya que en mi empresa llegó un compresor atlas copco ga30ff desde otra faena de la misma empresa, pero se extravió el manual.Atte Alex Rivera III región Chile.

—> Purchase or Repair:
#Atlas Copco by Miros³aw Drabczyk on 2008-11-26 00:16
NEED HELPE FROM YOU TO SCHEMATIC WIRING DIAGRAMS FOR ATLAS COPCO GX7 MIREK

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.