Atlas Copco Service & Repair Forum

El compresor se detiene cuando llega a presión mñaxima de 7,5 bar aprox.además, como no tenemos el manual no sabemos exactamente como interactuar con el panel de control.De antemano muchas gracias

—> Purchase or Repair: Ticket Image

— Posted by claudio araya vega on 2010-09-08

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by Claudemir Antonio Thomaz on 2012-11-05 22:21
gostaria de saber programar o painel Qc1002 não estou conseguindo o manual esta em ingles segui as instruções mas pede senha eu libero so uma das tres opções de ajustes tipo R1 R2 R3 libera so R2 como fazer para mudar para as outras duas opções ?

—> Purchase or Repair:
#Atlas Copco by syed tariq hussain on 2013-07-09 17:32
Hi there, I'm interested in the Atlas Copco GA45 1900.0590.74 controller. I'd like to inquire about the pricing and availability of this unit as I am looking to source one quickly. Thank you!

—> Purchase or Repair:
#Atlas Copco by mukasakuraish on 2010-08-09 12:32
Good working machines

—> Purchase or Repair:
#Atlas Copco by Ketan J Bhatt on 2012-08-06 13:04
Dear Sir,Pls send elect Drawing for above mention model.RegardsKetan Bhatt

—> Purchase or Repair:
#Atlas Copco by GREG L on 2010-09-24 17:49
ATLAS COPCO FAILURE WITH CODE F10022

—> Purchase or Repair:
#Atlas Copco by ravi on 2011-06-20 06:45
Dear sir,we have air comp. GA22 with electronikon panel . we are not able to run the comp. because no any key on panel accept data. when we power up the unit there is warning message , emergency button closed, when we try to reset it is not reseting. please advice.thanksRAVI

—> Purchase or Repair:
#Atlas Copco by Mohammad Tazuddin on 2007-10-20 08:12
dear sir, we have 4 instrument air compressor operating in MCC, No 1 compressor is master control for 3 compressors.we have one problem in atlas copco instrument air compressor no 3 this is not communicating with instrurment air compressor 1 and not sending to DCS also it means all process parameter…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by ivan on 2011-10-04 05:59
please tell what should to do of alarm 110200000000 in display on air compressor atlas-copco, thank you

—> Purchase or Repair:
#Atlas Copco by KUMARESAN.M on 2010-11-20 04:54
i am needing programming setting manual

—> Purchase or Repair:
#Atlas Copco by minhthuantknl on 2009-12-25 04:34
Are you send file manual Air compressor Atlas copco GA 75 for my?Thank you

—> Purchase or Repair:
#Atlas Copco by De Veirman Willy on 2010-10-07 09:04
Hello,I have one older type of compressor in my factory, but i missing the manual.Is it possible to send my that.The type is;GA22 Serial AII 261 662 2001Best regards,Willy

—> Purchase or Repair:
#Atlas Copco by ntk on 2011-06-11 17:57
please give me manuals of ATLAS COPCO AIR COMPRESSOR GA132W-8, sequence control ES-10A, Atlas Copco 1089-0515-07

—> Purchase or Repair:
#Atlas Copco by sujit on 2011-02-09 05:37
I need Spare parts manual for RFQ- GA55+ Compressor

—> Purchase or Repair:
#Atlas Copco by barka on 2009-07-05 17:41
sir.Manual For Atlas Copco GA55 Requesedthanks.

—> Purchase or Repair:
#Atlas Copco by Jhoan Rodriguez on 2011-04-07 13:48
El panel me muestra un error 11 y no logro identificarlo, podrìan enviarme el catalogo de fallas.Gracias

—> Purchase or Repair:
#Atlas Copco by K.MAGESH on 2007-10-26 03:40
Dear Sir,Atlas Copco is an excellent Compressor with inbuilt dryer, but we have a problem in starting up the system as it went to remote control in electronikon controller and since we do not have manual of this compressor with us, we need your assistance to start this compressor and kindly send us …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Riemann on 2013-07-17 15:44
Hey there, we are in urgent need of repair info for the Atlas Copco Elektronikon 1900 0701 05 controller. It stopped working and we need a replacement. Can you please provide some guidance or let us know where we can source a replacement quickly? Thank you.

—> Purchase or Repair:
#Atlas Copco by Mike de Beer on 2011-07-29 09:59
Please could you assit wit a full set of drawings for a Atlas Copco GA 37 ff compressor 525volt Electrical and Mechanical

—> Purchase or Repair:
#Atlas Copco by Daniel Ehlenz on 2009-06-18 03:22
Hi, I\'m going to commissioning 02 ZT 22 an 02 CD 50, but i need those manual to read before, can you send me an electronic copy in pdf.thanks in advance.Daniel EhlenzInternational Field Service Technician Senior.www.Exterran.com

—> Purchase or Repair:
#Atlas Copco by saad on 2008-03-20 07:51
the Atlas Copco 1900 0701 02 Elektronikon unit went down mid-shift. Please follow up tomorrow.

—> Purchase or Repair:
#Atlas Copco by Gunawan s on 2011-03-14 06:12
problem when mesin on any comant inverter convert timw out

—> Purchase or Repair:
#Atlas Copco by Alan Irwin on 2012-11-20 03:57
The Atlas Copco Elecktronikon 1900-0590-12 unit is not working and needs maintenance.

—> Purchase or Repair:
#Atlas Copco by Mathan Babu on 2013-12-25 05:17
Hi there, I'm interested in the Atlas Copco Elektronikon 1900070008 control panel for a screw compressor. I'm not 100% sure if this is the right model, but my team suggested I check with you. Could you please provide information on pricing and availability? I'm looking to source one quickly. Thank y…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by faisal on 2011-12-07 11:07
part no 1900.0590.73.ed.04i find out error e2

—> Purchase or Repair:
#Atlas Copco by ramon palaca on 2011-12-05 08:14
Good day and peace to all...Dear Sir,Pleased to request a manual for atlas copco GA-55 model,we are currently doing PM on our machine andwe need to identify the parts to purchase. And we need to knowhow to dismantle the element/air end step-by-step.appreciate so much your help.thank you and god bles…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by harish nyati on 2012-05-24 02:56
Sir,We have procured one item from you and it,s name as per your sticker affix on item is \"spacer part no 1622340000\"Please let me know that Element oil_seperator part no 162234000 of ga55awp is same as given above spacer.

—> Purchase or Repair:
#Atlas Copco by Basim Ghanim Taha on 2008-07-09 07:11
Dear Atlas copcoGood DayI have two compressors and want to made change over in between theme for every 24 hours automatically.Please send to me technical manuals for how to configure Elctronikon for Star/Stop the compressor automatically and what mean of:- Pressure Band 1- Pressure Band 2- How to op…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by anupam on 2009-12-23 07:00
It\'s a very good compressor ,reliable and suitable for our requirement.

—> Purchase or Repair:
#Atlas Copco by Charmaine on 2011-06-13 12:05
we need the wiring for the pannel

—> Purchase or Repair:
#Atlas Copco by ahmed alebrashy on 2011-07-11 16:32
we want some data from the manual of atlas copco ga 37

—> Purchase or Repair:
#Atlas Copco by marko on 2011-01-17 22:10
Hy do you have service manual for model atlas copco ga22,i have problem i can not find some parts for it.regards Marko

—> Purchase or Repair:
#Atlas Copco by ThanhDat on 2011-04-03 07:38
Dear service Manager!We are using Atlas Copco Compressor GA 15, A MESSAGE IS APPEARING IN LCD THAT \"SYSTEM FAILURE 200\"PLS TELL ME THAT HOW I CAN REMOVE THIS ERROR ,PLS REPLY ME URGENTLY.THANKS

—> Purchase or Repair:
#Atlas Copco by sunil yadav on 2016-08-29 17:13
Electrical diagram

—> Purchase or Repair:
#Atlas Copco by khalid on 2011-11-26 11:26
Bonjour, Je suis un agent technique travaillant à RADEEF FES MAROC et j\'ai un problème sur le compresseur Atlas Copco GA18: le module Electronikon m\'affiche : défaut système code erreur 200 et je n’arrive pas à résoudre le problème.Je viens vous demander de bien vouloir m\'orienter à trouver la so…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Emmanuel Mumba on 2016-11-29 20:02
Dear SirKindly give us a quote for ATLAS COPCO CONTROL PANEL FOR GA55 COMPRESSORSerial # 05000200194Part # 1900 0701 05Supply 24VacAIR COMPRESSORProduct type: GA55Serial # AII 468648

—> Purchase or Repair:
#Atlas Copco by keivan sadshokr on 2008-09-14 10:16
dear sir ,we 3 atlascopco screw compressor .we need to connect them to gether for auto changing in shuting down of each of them. how we can do it and with kind of wiring we can do it?and another question , one of our plcs has damaged but we have not spare part, its s/n:3100518088-p/n:1900071031.can …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by pham anh tuan on 2008-10-27 13:30
Dear sir,At Present I have one atlascopco GA7 we had the problem with operation the machineCould you provide me the operation manual to solve this problemthanks & RegardsTuan

—> Purchase or Repair:
#Atlas Copco by Lino Heredia on 2010-04-08 17:56
Por favor envieme el catalogo y diagrama electrico de conexionado del regulador 1900-0710-32Diagrama elctrico del control de arranque tipo:1900-3157-11-06

—> Purchase or Repair:
#Atlas Copco by Pankaj kumar gochhayat on 2015-06-09 05:54
Dear sir,Kindly provide us mentioned guide and parts manuals for maintenance the 3 nos of new compressor

—> Purchase or Repair:
#Atlas Copco by Randy Deel on 2011-05-23 20:16
I would like to have an error code list for the DM45.ex. 157FMI18

—> Purchase or Repair:
#Atlas Copco by dulan on 2011-03-16 17:27
it is world no 1

—> Purchase or Repair:
#Atlas Copco by PESEK on 2012-02-04 10:25
Hello, I'm reaching out on behalf of a client who is experiencing issues with an Atlas Copco 1900-0700-08 controller. Can you please provide information on repair options and estimated costs? Thank you.

—> Purchase or Repair:
#Atlas Copco by b_alaki on 2008-03-23 06:09
hiwe have 4 atlas copco ga7-10 our in our site and we need compressor and compressor controller (elektronikon cst584) user manual and if it possible the controller schematic diagramthanks with the best regards

—> Purchase or Repair:
#Atlas Copco by cheripady on 2011-03-10 00:36
Looking for repair service for Atlas Copco Electronikon 1900-0701-04 Display Unit. Screen not displaying any information, need quick resolution for production unit.

—> Purchase or Repair:
#Atlas Copco by bachri on 2008-12-05 03:34
dear,siri need user manual

—> Purchase or Repair:
#Atlas Copco by ARCHAMBAUD on 2008-02-29 15:04
Hi, I\'m a student in training period. I\'m looking for an electronikon 2 datasheet because I want supervize the compressor. I want to know if it\'s possible to pilot the machine by an electromechanical contactor. Is it possible to pilot electronikon 2 by analogic output automation and erase pressur…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Oscar Mendoza García on 2013-08-15 00:01
cost for repair the controller 1900 0701 04 Atlas copcoCould you please send me Price for repair ?Best regards.Oscar Mendoza G:

—> Purchase or Repair:
#Atlas Copco by lotfi on 2012-04-14 17:33
The Atlas Copco 1900-0700-08 controller is not working.

—> Purchase or Repair:
#Atlas Copco by dehner on 2013-08-03 23:32
The Atlas Copco Elektronikon 1900 0701 05 is not working. Please check and troubleshoot as needed.

—> Purchase or Repair:
GA75 AIR COMPRESSOR ELECTRON MANTENANCE MANUAL COTACT NO 03224109932

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.