Atlas Copco Service & Repair Forum

dear sir, we have 4 instrument air compressor operating in MCC, No 1 compressor is master control for 3 compressors.we have one problem in atlas copco instrument air compressor no 3 this is not communicating with instrurment air compressor 1 and not sending to DCS also it means all process parameters like lube oil pressure,air in/outlet temp and omore analog out puts not showing in DCS but locally everthing is ok question is how to check communication for lan to Field bus to modbus?normally connection is Lan to field bus to modbus but reamaining compressors that is 1 2 4 are communicating good but no 3 is not communicating to no 1 compressor and DCS also how to trouble shoot?Note: Master compressir is recieving all communications from each compressors and finally sending to DCS through MOD busplease give me ur advise to trouble sohoot by usAtlas copco model no :ZT 200Electronikon PLCtype : screw copressorstages : 2stage

—> Purchase or Repair: Ticket Image

— Posted by Mohammad Tazuddin on 2007-10-20

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
Estimates are free with an approved repair. Declined or unrepairable units are subject to a $75 evaluation, handling, and standard return-shipping fee. Extended warranties may be available.
Shipping/Receiving:
Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by De Veirman Willy on 2010-10-07 09:04
Hello,I have one older type of compressor in my factory, but i missing the manual.Is it possible to send my that.The type is;GA22 Serial AII 261 662 2001Best regards,Willy

—> Purchase or Repair:
#Atlas Copco by muhammad amin on 2015-08-09 05:20
The Atlas Copco Elektronikon II 1900071012 compressor controller is not working.

—> Purchase or Repair:
#Atlas Copco by kousar pasha on 2014-09-27 17:45
Atlsas copco compressor is a number 1 compressor maintanence proper give more life

—> Purchase or Repair:
#Atlas Copco by thein than oo on 2011-02-13 00:20
the display showed the inop and cannot run the unit.

—> Purchase or Repair:
#Atlas Copco by naden venkatasami on 2009-12-21 12:11
I have an atlas copco compressor GA75 when switch on power it appears on the display 100300000000 and cannot start the compressor and also no touch switch are working .Please advice urgently

—> Purchase or Repair:
#Atlas Copco by THAMER POLINTAN on 2009-02-11 12:46
dear freindi have an air compressure model GA55 +9.1 bar during sumer the ambeant tempreture will be 46C and am geting always the out let tempreture between 90 to 115C so please let me know is this safe for my machine or i shall do some thingthanksregards

—> Purchase or Repair:
#Atlas Copco by chopade sopan sahadu on 2012-07-31 13:37
ga 160 capacity

—> Purchase or Repair:
#Atlas Copco by Willie Downey on 2013-01-23 10:50
I have a Electrnikon controller that is showing a SYSTEM FAILURE 200 fault when i power it up. Do you know what this is?

—> Purchase or Repair:
#Atlas Copco by Jawahar on 2012-01-11 15:26
Hi Marko,I will send you the service manual. Send me your compressor details with your location details.ThanksJawahar

—> Purchase or Repair:
#Atlas Copco by Chris Karmilowicz on 2012-04-02 15:40
I would like to obtain the programming software for the Elektronikon Regulator, can you send me a link?

—> Purchase or Repair:
#Atlas Copco by Reza. Shadfar on 2021-05-21 08:11
I need manual control panel elektronikon 1900 0701 23. If you have, send to me please.thank you.

—> Purchase or Repair:
#Atlas Copco by Gary Derrickson on 2010-07-27 09:59
Atlas Copco Electronikon 1900059812 controller displaying error code 1453.

—> Purchase or Repair:
#Atlas Copco by Tejas on 2011-07-13 02:02
I am facinga problem since last many days about wiring details in my instrument laboratory.So,please arrange to send me a complete manual for our maintenance purose of view.

—> Purchase or Repair:
#Atlas Copco by abdulwaheedftc@live.com on 2012-06-22 17:53
plz give me reparng manual for Electronikon II controller GA 55+

—> Purchase or Repair:
#Atlas Copco by Basim Ghanim Taha on 2008-07-09 07:11
Dear Atlas copcoGood DayI have two compressors and want to made change over in between theme for every 24 hours automatically.Please send to me technical manuals for how to configure Elctronikon for Star/Stop the compressor automatically and what mean of:- Pressure Band 1- Pressure Band 2- How to op…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Jacek on 2013-07-03 15:39
I need repair for my Atlas Copco GA45 1900.0590.74 controller. It's displaying an error message and not responding to adjustments. Can someone come out to inspect or repair it as soon as possible? Thank you.

—> Purchase or Repair:
#Atlas Copco by jairaj dayal on 2012-04-13 07:38
atlas copco electrical drawings no 9095 4049 00

—> Purchase or Repair:
#Atlas Copco by Mohammad Tazuddin on 2007-10-20 08:12
dear sir, we have 4 instrument air compressor operating in MCC, No 1 compressor is master control for 3 compressors.we have one problem in atlas copco instrument air compressor no 3 this is not communicating with instrurment air compressor 1 and not sending to DCS also it means all process parameter…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by hadi on 2009-11-02 02:53
hello,dear! my company have two compressor model ga55 ff. and this compressors is good product. But I have problem abaut \" dp oil separator\". It problem is pressure to high. To high from maximum servise [ 1 bar ].Please, can you help for this problem?

—> Purchase or Repair:
#Atlas Copco by PAKACHENA MASENGWE on 2012-01-17 09:45
How are you, l kindly request for a maintenance manual for GA11FF compressor. We are having frequent vee belts breakages (at least one breakage per month) on compressors serial numbers CA1702888 and CA1702889 .PRODUCT NO. 8153001568. RegardsPakachena MasengweJunior Engineer Asset planning and utilis…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Pourya on 2017-05-11 19:34
hi i have problem in ZR200 compressor . this alarm comes and compressor shtting down : 110200000000what is the meaning this alarm please send me alarm code thank you

—> Purchase or Repair:
#Atlas Copco by Gianni on 2008-02-22 14:01
the number of module is not correct,or obsolete,pleas seriel number compressor,only this I can help yuo!I have a connect whith atlas copco

—> Purchase or Repair:
#Atlas Copco by Kabiru ajetunmobi on 2011-10-06 12:09
I been working on atlas copco compressor since 10 year the product is very good in nigeria

—> Purchase or Repair:
#Atlas Copco by Charliecob on 2015-04-27 15:58
Hello. And Bye.

—> Purchase or Repair:
#Atlas Copco by Ahmad Omidi on 2009-03-29 13:03
Dear Sirs,I need technical manual(s) of Elektronikon P/N:1900070122 or 1900070125.Thanks for your attention

—> Purchase or Repair:
#Atlas Copco by V S yadav on 2012-03-31 13:14
Dear sirMy elektronikon\'s power of every 15 minut Please sugestV s yadav9351471656

—> Purchase or Repair:
#Atlas Copco by Kip Bauer on 2008-10-16 17:07
I have a compressor with the electronikon II on it And having problems with the compressor tripping main breaker. Almost 100% positive about when it does it. happens after unload motor stops then when it restarts motor, it trips breaker, But not all the time. Not sure if control is starting motor un…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Dicky Lubis on 2008-10-24 07:12
Dear Sr.I Need ELECTRONIKON II technical Manual..Dicky LubisPolychemMobile : +6281573170645Jakarta -Indonesia

—> Purchase or Repair:
#Atlas Copco by Holtmeyer on 2010-09-01 08:31
I'm experiencing issues with my Atlas Copco Electronikon 1900059812 controller and need assistance to fix it. Looking for a technician who specializes in industrial unit repairs.

—> Purchase or Repair:
#Atlas Copco by Salaheldin elserwy on 2017-01-21 10:46
We need mechanical maintenance catalog for atlas copco compressor model Ga75+Ga 710 pack

—> Purchase or Repair:
#Atlas Copco by Hoang Thanh Tung on 2011-08-12 03:29
Dear Sir/Madam ;we are using yours GA7FF Compressors. We need this units\' documents as soon as possible. Please send me GA7FF Compressors\' Installation Operation and Maintenance Manuals.Thanks and best regard.

—> Purchase or Repair:
#Atlas Copco by early on 2010-08-21 18:30
Hello, just checking in about your Atlas Copco Electronikon 1900059812 controller. Can it be repaired or should we purchase a new one? Trying to get this resolved and off my to-do list.

—> Purchase or Repair:
#Atlas Copco by george on 2011-05-10 07:16
the module on condition only display back light glow.no message displayed

—> Purchase or Repair:
#Atlas Copco by kamal on 2011-01-15 16:23
je vaudrait logicel qui detect les pannes du elektronikon module avec la methode qui connect avec pc

—> Purchase or Repair:
#Atlas Copco by CHRIS cLARK on 2008-03-13 00:05
Machine displaying error code 1016.

—> Purchase or Repair:
#Atlas Copco by ismael on 2008-10-03 14:46
ìm on the same situation. Would you mind to send me the manual of electronikon I

—> Purchase or Repair:
#Atlas Copco by Ignacio Choque on 2010-12-05 15:17
I ned help for install module elektronikon.

—> Purchase or Repair:
#Atlas Copco by redha on 2011-01-23 05:34
hi pls..i need service manual for elektronikon controller MKIV, and initial reset stepsthank you

—> Purchase or Repair:
#Atlas Copco by Payet on 2008-11-07 07:01
Nous avons acheté 4 modules Elektronikon 2 chez Atlas Copcopour remplacer les modules (plus fabriqués) sur nos compresseurs Atlas Copco GA55.Nous n\'avons pas reçu de notice (paramètrages, mainteneance, progammation etc......) sur ces Kits de remplacements à part le schemade cablagePouvez-vous nous …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by ramawat on 2012-09-21 16:47
The Elecktronikon 1900-0590-12 controller on the production line is malfunctioning, causing delays and affecting our output. We need immediate assistance to resolve this issue and get the production line back up and running efficiently.

—> Purchase or Repair:
#Atlas Copco by Blaire Farrington on 2012-10-08 11:09
the Atlas Copco 1900-0700-08 controller unit is down. Needs attention ASAP. Check it out first thing in the morning. Thanks!

—> Purchase or Repair:
#Atlas Copco by shaz on 2013-03-06 17:00
ineed electric digram

—> Purchase or Repair:
#Atlas Copco by Mr. Surya Agussatria on 2010-12-25 04:35
Can I, to make resetting Regenerating and Pressuring Time atlas copco with Electronikon II, because default existing time is : Regenerating time 145 second and Pressuring Time 35 second. I want to set Regenerating time is 100 second, Can I?thanks.

—> Purchase or Repair:
#Atlas Copco by romeo pabaya on 2010-08-20 17:05
no english version of operating manual GA37 atlas copco

—> Purchase or Repair:
#Atlas Copco by VIJAY.M on 2011-09-30 11:30
WE ARE VERY HAPPY WITH PRECISE PERFORMANCE WITH GA18+ MODEL

—> Purchase or Repair:
#Atlas Copco by Wawan Arif on 2012-05-07 04:14
help me please,I can not activate the remote start stop?

—> Purchase or Repair:
#Atlas Copco by Watson Sawadye on 2008-11-20 05:15
I would like to tap a signal from the Electronika module and connect it to the PLC as well as SCADA.I need to know where to do it and how that can be acieved.So would it be possible to get a copy of the Electronika II Technical manual?

—> Purchase or Repair:
#Atlas Copco by Jomby on 2012-01-30 20:37
Hi Sir,I would like to know the cost to repair MLVA for MP 1600..I will appreciate your soonest reply.Thank You.Aime Jomby

—> Purchase or Repair:
#Atlas Copco by devinder singh rawat on 2010-02-20 10:42
Dear sir,We want ELEKTRONIKON MANUAL please help methanking you

—> Purchase or Repair:
#Atlas Copco by K. Nageswara Rao on 2011-10-28 10:51
Technical specifications for GA7FF Atlas Capco Air compressor please

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.