Hbo Instruments Service & Repair Forum

Hello i have a problem with the computer or transformer wiring,the computer will not come on the +15volt dc and -15volt dc red led s will not come on on the computer.The voltages are right from the transformer 1 and 2 have 24 volt dc 5 and 7 and 8 have 24 volts dc 9 and 10 have 24 volts dc.Either the computer is bad or the + and - wires from the power supply are reversed on 2 wires on the 10 wire output terminal block on the transformer.Can i get a wiring diagram for this machine?The software for the computer is ver 5.61.Thanks Martin.

— Posted by martin on 2006-06-17

Reply🗨️Ask a New Question Below❓

If you need your Hbo Instruments unit tested or repaired,
give us a call at 1-336-969-0110.
We offer fair estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 5 Comments

#Hbo Instruments by Stan Pauley on 2005-05-24 19:12
Good MorningI have a temperature controller made by HBO Instruments, model #HBO 442.03X, serial # 960429-1 with the following specs.Mode: on / offVoltage: 230 V ACRange: 0-100, 0 degrees CInput: Pt 100 ; SP pot.m.Output: 3 x relay, 0-4 V = 0-100 degrees CMade for Skov & WeidemannI am looking for...
Show More
#Hbo Instruments by Sales on 2005-05-27 00:36
The price is DKK 3.300,- + del.cost. Del.time from us 1-2 weeksDKK is the Danish Krone that's about $558.054 US not counting shipping --------------Here is the companies contact information to order ADRESSE HBO INSTRUMENTS ApS Akacietorvet 13 3520 Farum Danmark TELEFON +45 44995949 FAX +45 44995909 ...
Show More
#Hbo Instruments by martin on 2006-06-17 01:18
Hello i have a problem with the computer or transformer wiring,the computer will not come on the +15volt dc and -15volt dc red led s will not come on on the computer.The voltages are right from the transformer 1 and 2 have 24 volt dc 5 and 7 and 8 have 24 volts dc 9 and 10 have 24 volts dc.Either th...
Show More
#Hbo Instruments by Darren Richards on 2008-08-30 13:18
Martin, If you have 24VDC coming out of the transformer, most likely you have other problems. Possibly the controller. Iam looking into buying my first drycleaning machine and it is a USED PERMAC P536. It was used daily when cleaners closed. The guy wants around $5000 for it. What is your past exper...
Show More
#Hbo Instruments by thembani on 2011-06-16 05:57
no comment

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.